exceeding 120V (60V) DC or 50V (25V) rms. AC is working. The values in brackets
are valid for limited ranges (such as medicine and agriculture). Measurements in
dangerous proximity of electrical systems are only allowed directed by a qualified
electrician and never alone..
Check the meter and test leads before each use for exterior damage. Make sure that
the meter and the connecting cables are used in perfect condition. The instrument
may no longer be used if one or several functions fail or if no functional reliability can
be detected. If the operator's safety is no longer guaranteed, the device must be shut
down and be protected against use. This case finds application when the device:
• shows obvious damage
.
• does not carry out the desired measurements.
• was stored under unfavourable conditions for a long period of time.
• has been exposed to mechanical stresses during transport.
If the device is exposed to an extremely high electromagnetic field, the function may
be affected.
Never attempt to disassemble a battery! The electrolyte in the cell is highly alkaline.
Burns! When it comes to contact with skin or clothing, these areas must be rinsed off
immediately with water.
If electrolyte gets in the eyes, immediately flush with clean water and consult a
doctor.
Never try to connect the two poles of a battery cell, for example, with a wire. Never
throw the batteries in a fire, as this could cause an explosion. Never expose batteries
to moisture. Note, when changing the battery to correct polarity. Wrongly polarized
batteries may destroy the device, furthermore, they may explode or ignite. Only use
the specified batteries! Avoid the instrument from direct sunlight and heat. Only then,
a proper function and a long service life are assured.
Normal use
The device may only be used under the conditions and for the purposes for which it
was designed. The operational safety is no longer guaranteed for modified or
adapted devices.
Connect the transmitter OE - SF T30V
(single pole application)
Connect the transmitter to only one conductor. The signal generated by the
transmitter is a high-frequency signal, even a single conductor can be searched or
tracked. The second circuit replaced the earth. With this arrangement, a high
frequency current flows through the conductor, over the air back to earth, very similar
to a radio transmitter and a radio receiver. We want to call this described mode from
now on “single pole application”.