General instruction for ORP electrodes

 

Instrucciones generales para electrodos POR 

Instructions générales pour les électrodes de 

Potentiel d'oxydo-réduction (PRO)

 

 
 
 
 
 
 
 
 

 
 
 
 
 
 

Ohaus Corporation 

7 Campus Drive  

Suite 310  

Parsippany, NJ 07054 USA 

Tel:  (973) 377-9000 

Fax: (973) 944-7177 
With offices worldwide 

Con oficinas en todo el mundo 

Avec des bureaux dans le monde entier 

 

www.ohaus.com; [email protected] 

*30040261* 

P/N 30040261 C © 2015  

Ohaus Corporation, all rights reserved/ todos 

los derechos reservados/ tous droits réservés 

Summary of Contents for STORP1

Page 1: ...ustin Ft Worth NicolScales com 800 225 8181 Contact Us Nicol Scales Measurement is an ISO Accredited Calibration Company that has provided calibration repair and sales of all types of weighing and mea...

Page 2: ...duction PRO Ohaus Corporation 7 Campus Drive Suite 310 Parsippany NJ 07054 USA Tel 973 377 9000 Fax 973 944 7177 With offices worldwide Con oficinas en todo el mundo Avec des bureaux dans le monde ent...

Page 3: ...EN 2 ORP electrodes...

Page 4: ...ence Electrolyte Gel 3M KCl STORP1 Solution 3M KCl STORP2 Zero potential value 86mV 15mV Grade difference 165mV The ORP electrode is also called Redox electrode measures the Oxidation Reduction Potent...

Page 5: ...after measurement to avoid leakage 4 After measurement rinse the ORP electrode with pure water and store back in the small protection bottle with soaking solution ORP electrode quality check To check...

Page 6: ...should clean the electrode as follows 1 Inorganic contamination dip the ORP electrode into 0 1M HCl for more than 10 minutes then rinse with pure water Soak the ORP electrode in 3M KCl solution for m...

Page 7: ......

Page 8: ...rio STORP2 Rango de temperatura 0 80 STORP1 0 100 STORP2 Electr lito de referencia Gel 3M KCl STORP1 Soluci n 3M KCl STORP2 Valor potencial cero 86 mV 15 mV Diferencia de grado 165 mV El electrodo ORP...

Page 9: ...el orificio de llenado durante la medici n y recuerde cerrarlo despu s de la medici n para evitar goteo 4 Despu s de la medici n enjuague el electrodo POR con agua pura y vuelva a almacenarlo en el fr...

Page 10: ...el electrodo de la siguiente manera 1 Contaminaci n inorg nica Sumerja el electrodo POR en HCl 0 1M durante m s de 10 minutos y luego enjuague con agua pura Enjuague el electrodo POR en soluci n 3M KC...

Page 11: ......

Page 12: ...f rence Gel 3M KCl STORP1 Solution 3M KCl STORP2 Valeur potentielle du z ro 86 mV 15 mV Diff rence selon la qualit 165mV L lectrode de Potentiel d Oxydo R duction porte aussi le nom de Redox elle mesu...

Page 13: ...refermer apr s la mesure afin d viter des fuites 4 Apr s la mesure rincer l lectrode PRO l eau pure et la ranger dans la petite bouteille de protection avec une solution de stockage V rification de l...

Page 14: ...ante 1 Contamination inorganique tremper l lectrode PRO dans de l HCl 0 1 M pendant plus de 10 minutes et la rincer ensuite dans de l eau pure Faire tremper l lectrode de potentiel oxydo r ducteur dan...