OHAUS Scout SPX Quick Start Manual Download Page 3

Quick Start Guide

Scout

 SPX Balances

 

Ohaus Corporation  www.ohaus.com                

iii

 

                

Scout

 

SPX Balances

 

Button 

 

 

 

 

 

Short Press 

Zero/On 

Turns the 
balance on; 
If balance is 
On, sets Zero 

Print 

Initiates print 

Function 

Initiates an 
application 
mode 
 

Tare 

Tare 

Long Press 

Off 

Turns the 
balance Off 

Units 

Changes the 
weighing unit 

Mode 

Changes the 
application 
mode 

Menu 

Enters the 
User menu 

Short Press 
(Menu 
Function) 

Yes 

Accepts the 
current setting 

No 

Advances to 
the next menu 
or setting 

Back 

Moves to 
previous 
menu item 

Exit 

Exits the User 
menu 
 

CALIBRATION

 

When the balance is operated for the first time, a span calibration is 
recommended to ensure accurate weighing results. With balance turned on:

 

Step-1 

Press and hold 

Menu

 until [

mMeNU

] (Menu) is displayed.

 

Step-2 

Release the button, the display will show [

C.A.L

]. 

Step-3 

Press 

Yes

 to accept. [

SpaN

] will then be shown. 

Step-4 

Press 

Yes

 to begin the span calibration. Zero reading is stored 

automatically.  

Step-5 

Place the specified span calibration mass or press 

No

 to select an 

alternate weight. 
[

--C--

] will be displayed while the reading is stored

 

The display will show [

done

] if the calibration was successful. The balance 

returns to the previous application mode and is ready for use.  

 

OPERATION & APPLICATIONS

 

The balance can be configured to operate in various Application modes. Press 
and hold 

Mode

 key to select your Application mode.  

The Scout SPX balance incorporates the following Applications:

 

[

wWEIGH

[

Count

]

 

[

Percnt

]

 

[

CHECk

]

 

[

total

]

 

[

Hold

]

 

Weighing 

Parts 

Counting 

Percent 

Weighing 

Check 

Weighing 

Totalization 

Display 

Hold 

 

Summary of Contents for Scout SPX

Page 1: ...pid temperature changes PREPARATION FOR USE Step 1 Release the red Transportation Lock on subplatform of the balance Turn the pointer 90 counter clockwise Step 2 Install the Pan Rectangular pan Place...

Page 2: ...voltage range printed on the AC adapter s ratings label Only connect the AC adapter to a compatible grounded socket Position the instrument such that the AC adapter can be easily disconnected from the...

Page 3: ...ce turned on Step 1 Press and hold Menu until mMeNU Menu is displayed Step 2 Release the button the display will show C A L Step 3 Press Yes to accept SpaN will then be shown Step 4 Press Yes to begin...

Page 4: ...Off 1 5 10 Reset Yes No Weighing On Off Counting On Off Percent On Off Check On Off Totalize On Off Hold Disp Peak Off Reset g kg ct N oz ozt dwt lb lb oz grn hkt sgt twt t tola tical C End End End En...

Page 5: ...t www ohaus com ce This product complies with the EU Directive 2002 96 EC WEEE Please dispose of this product in accordance with local regulations at the collecting point specified for electrical and...

Page 6: ...EL USO Paso 1 Libere el bloqueo de transporte de color rojo ubicado en la sub plataforma de la balanza Gire el puntero 90 en sentido antihorario Puntero de bloqueo de transporte Paso 2 Instale el pla...

Page 7: ...ecificaciones del adaptador de CA Solo conecte el adaptador de CA a una toma compatible con conexi n de tierra Posicione el instrumento de tal forma que el adaptador de CA se pueda desconectar f cilme...

Page 8: ...esionado Menu hasta que aparezca mMeNU Menu Paso 2 Suelte el bot n la pantalla mostrar C A L Paso 3 Pulse Yes para aceptar SpaN se mostrar a continuaci n Paso 4 Pulse Yes para comenzar la calibraci n...

Page 9: ...s No Weighing On Off Counting On Off Percent On Off Check On Off Totalize On Off Hold Disp Peak Off Reset g kg ct N oz ozt dwt lb lb oz grn hkt sgt twt t tola tical C End End End End Nota Las letras e...

Page 10: ...n l nea en www ohaus com ce Este producto cumple la directiva de la UE 2002 96 EC WEEE Deseche este producto de acuerdo con las normativas locales en el punto de recogida indicado para los equipos el...

Page 11: ...l UTILISATION tape 1 D verrouiller le verrou de transport rouge sur le socle de la balance Tourner l indicateur de 90 dans le sens antihoraire Etape 2 Installer le plateau Plateau rectangulaire Placer...

Page 12: ...ette de l adaptateur CA Uniquement raccorder l adaptateur CA une prise avec mise la terre Positionner l quipement de fa on ce que l adaptateur CA puisse facilement tre d branch de la prise Positionner...

Page 13: ...er et maintenir Menu jusqu ce mMeNU Menu soit affich Etape 2 Rel cher le bouton l affichage indique C A L Etape 3 Appuyer Oui pour accepter SpaN est alors affich Etape 4 Appuyer Oui pour commencer l t...

Page 14: ...ff 1 5 10 Reset Yes No Weighing On Off Counting On Off Percent On Off Check On Off Totalize On Off Hold Disp Peak Off Reset g kg ct N oz ozt dwt lb lb oz grn hkt sgt twt t tola tical C End End End End...

Page 15: ...e Le pr sent produit est conforme aux Directives 2014 30 UE EMC 2014 35 UE LVD et 2014 31 UE NAWI La d claration de conformit UE est disponible en ligne sur le site www ohaus com ce Le pr sent produit...

Page 16: ...informations sur la balance se reporter au manuel d instructions On peut obtenir le manuel d instructions soit par balayage du code QR code ou en se rendant sur la page produit Scout SPX pour le t l...