EN 24                                                                                             Ranger  4000 Count Series    

5. LEGAL FOR TRADE 

When the scale is used in trade or a legally controlled application it must be set up, verified and 
sealed in accordance with local weights and measures regulations. It is the responsibility of the 
purchaser to ensure that all pertinent legal requirements are met. 

5.1 Capacity Label 

A label showing the capacity and readability of the scale must be installed near each display. If 
the Capacity Labels were installed prior to delivery, no further action is needed. If the Capacity 
Labels  were  not  installed,  they  have  been  placed  in  the  packaging  material.  Affix  the  labels 
above the displays as shown in Figure 5-1. 

Note:

 The Capacity Labels will be destroyed upon removal, so only attempt to install them once. 

 

 

Figure 5-1. Capacity Label location 

 
 
 

5.2 Settings

 

Before verification and sealing, perform the following steps: 
1. Verify that the menu settings meet the local weights and measures regulations. 
2. Perform a calibration as explained in Section 3.9. 
3. Set the switch to Locked. See figure 5-1. 
 
The  Menu Lock  switch limits  changes  to  the  Cal,  Setup,  Readout,  Unit  and  Print  menus.  The 
switch  in  type  approved  models  may  set  some  scale  settings  as  required  by  the  approval 
agency. The switch may be secured using paper seals, wire seals or plastic ties.  
 

Note:

  When  LEGAL  FOR  TRADE  is  set  to  ON  (LFT  Switch  in  locked  position),  the  menu 

settings are affected as follows: 
 

Calibration (

C.A.L

) menu is not accessible 

 

Dual Scale, Capacity 2, Graduation 2 and Units are locked at their current settings 

 

Zero Range setting is locked at 2% 

 

Stable Range setting is locked at 1d 

 

Auto-Zero Tracking setting is locked at 0.5d 

 

Stable Only is locked On 

 

Auto Print/ Continuous is disabled 

 

Lb:oz is locked Offf 

 

5.2 Verification and Sealing 

The local weights and measures official or authorized service agent must perform the 
verification procedure. 
 

5.3.1 Physical Seals

 

For jurisdictions that use the physical sealing method, the local weights and measures official or 
authorized service agent must apply a security seal to prevent tampering with the settings. 
Refer to the illustration below for sealing methods. 
 
 

Capacity Label

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for R41ME15

Page 1: ...Range 4000 Count Series Instruction Manual www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 2: ...Alternating Current 1 2 Safety Precautions Please follow these safety precautions Verify that the AC input voltage printed on the data label matches the local AC power supply Only connect the power c...

Page 3: ...scale on a firm steady surface Avoid locations with excessive air current vibrations heat sources or rapid temperature changes Allow sufficient space around the scale 2 4 Leveling the Equipment The Ra...

Page 4: ...e battery charge level The scale will automatically turn off when the batteries are fully discharged For maximum operating time the battery should be charged at room temperature TABLE 2 1 Symbol Charg...

Page 5: ...ghing unit Switch between Check Weigh Check Count and Off Menu Enter user menu View the Audit Trail event counters extended press Menu Function Short Press Yes Accept the current menu or setting No Ad...

Page 6: ...3 2 LCD Symbols Item Description Item Description 1 NET symbol 10 Low Sample Weight Symbol 2 Center of Zero symbol 11 Auto Optimization Symbol 3 Negative symbol 12 Dynamic symbol not used 4 Stable wei...

Page 7: ...d hold the On Zero Off button until OFF is displayed 3 3 Counting Ranger Count 4000 has three display areas Weight Piece Weight and Count information are displayed in these areas respectively 3 3 1 Pr...

Page 8: ...size value only integer 5 Press the Sample key will be displayed in both the piece window and the count window 6 The established APW and count will be displayed Entering a known APW 1 Press the APW ke...

Page 9: ...eight is under the target weight range the yellow LED will light If the sample is within the target weight range the green LED will light If the sample is over the target weight range the red LED will...

Page 10: ...aximum 30 records from 0 to 29 Retrieving a record 1 Enter the ID number using the keypad and press the ID key and are displayed in the weight and piece weight windows respectively 2 ID number is disp...

Page 11: ...ad and press the ID key and are displayed in the weight and piece weight windows respectively 2 Press the C key is displayed in the weight window Press the Yes key to delete the data www GlobalTestSup...

Page 12: ...l models When LEGAL FOR TRADE is set to ON LFT Switch in locked position the menu settings are affected as follows Calibration C A L menu is not accessible Dual Scale Capacity 2 Graduation 2 and Units...

Page 13: ...erforming the calibration be sure to have the appropriate calibration weights as listed in table 4 1 Ensure that the LFT switch calibration lock is set to unlocked position See figure 5 1 Or adjust th...

Page 14: ...ing the default Refer to table 4 2 to determine the GEO factor that corresponds to your location End Cal Advance to the next menu or return to the top of the current menu 4 3 Setup Menu Enter this men...

Page 15: ...unces Zero Range Set the percentage of scale capacity that may be zeroed 2 zero up to 2 percent of capacity 10 zero up to 10 percent of capacity Auto Opt Set the Automatic Optimization OFF disabled ON...

Page 16: ...d Accumulation Set the accumulation functionality OFF accumulation disabled AUTO automatic accumulation MAN manual accumulation End Setup Advance to the next menu or return to the top of the current m...

Page 17: ...ic shut off functionality OFF disabled 1 powers off after 1 minute of no activity 5 powers off after 5 minute of no activity 10 powers off after 10 minute of no activity End Readout Advance to the nex...

Page 18: ...g occurs at the defined interval ACCEPT printing occurs continuously CONT printing occurs each time the display is within the Checkweigh accept range and stability criteria are met Content Define the...

Page 19: ...ON the reference information is printed APW Set the status OFF disabled ON enabled Accu Set the status OFF disabled RESULT the Accumulation result is printed ALL all the Accumulation data is printed L...

Page 20: ...7 setup contact Ohaus If the weighing value is a negative number set the target cell in TEXT format Otherwise Excel will not distinguish it as a negative number Please do not use this function during...

Page 21: ...ernate command Define command character for the Print Tare and Zero commands Print Set the alternate command character for Print A to Z Tare Set the alternate command character for Tare A to Z Zero Se...

Page 22: ...e status OFF COM menu is not locked ON COM menu is locked End Lock Advance to the next menu or return to the top of the current menu 4 9 End Menu current application mode 4 10 Additional Features To u...

Page 23: ...EN 22 Ranger 4000 Count Series Figure 4 1 Setup for the Weigh Below Hook Weigh Below Hook Access www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 24: ...3 12 12 43 26 44 32 17 17 16 16 15 15 14 14 13 13 12 44 32 45 38 18 17 17 16 16 15 15 14 14 13 13 45 38 46 45 18 18 17 17 16 16 15 15 14 14 13 46 45 47 51 19 18 18 17 17 16 16 15 15 14 14 47 51 48 58...

Page 25: ...h to Locked See figure 5 1 The Menu Lock switch limits changes to the Cal Setup Readout Unit and Print menus The switch in type approved models may set some scale settings as required by the approval...

Page 26: ...0 Count Series EN 25 Figure 5 1 Sealing Unlocked Locked with Paper Seal Locked with Wire Seal Paper Seal Wire Seal Lock Switch www GlobalTestSupply com Find Quality Products Online at sales GlobalTest...

Page 27: ...ot enabled Enter menu and enable unit Battery icon flashing Battery is empty Connect the scale to AC power and charge the battery Power On Error Weight reading exceeds Power On Zero limit Power On Err...

Page 28: ...x 0 001 kg 30000 g x 1 g 60 lb x 0 002 lb 960 oz x 0 04 oz Maximum Displayed Resolution 1 30000 Minimum Recommended Sample Weight 2g 0 004lb 4g 0 01lb 10g 0 02lb 20g 0 04lb Minimum Recommended APW 0...

Page 29: ...e or unstable P Print displayed weight stable or unstable CP Continuous Print SP Print on Stability xS xP Interval Print x Print Interval 1 3600 sec 0P turns auto print OFF Z Same as pressing Zero Key...

Page 30: ...tive pins PIN 2 TXD PIN 3 RXD PIN 5 Ground Figure 7 2 RS232 Pins 7 4 Printouts The following sample print outs are generated by the Print print command The content of the printout is defined in the Pr...

Page 31: ...haracters right justified at immediate left of most significant character if negative Unit Up to 5 characters left justified If the Unit in the Print Content menu was set to OFF the unit will be remov...

Page 32: ...ations limit the validity period of the verification the user of the weighing instrument must strictly observe the re verification period and inform the respective weights and measures authorities FCC...

Page 33: ...igned for safe removal of the batteries at end of life by a waste treatment facility Please dispose of this product in accordance with local regulations at the collecting point specified for electrica...

Page 34: ...osed to radioactive or corrosive materials has foreign material penetrating to the inside of the product or as a result of service or modification by other than OHAUS In lieu of a properly returned wa...

Page 35: ...ci in tutto il mondo 30037454 P N 30037454A 2015 OHAUS Corporation all rights reserved todos los derechos reservados tous droits r serv s Alle Rechte vorbehalten tutti i diritti riservati Printed in C...

Reviews: