OHAUS CS 2000 Instruction Manual Download Page 17

 
 

 

EN-15

Valor 2000 Series Scales

 

 

Disposal 

In conformance with the European Directive 2002/96 EC on Waste Electrical 
and Electronic Equipment (WEEE) this device may not be disposed of in 
domestic waste. This also applies to countries outside the EU, per their 
specific requirements. 

Please dispose of this product in accordance with local regulations at the 
collecting point specified for electrical and electronic equipment. 

If you have any questions, please contact the responsible authority or the 
distributor from which you purchased this device. 

Should this device be passed on to other parties (for private or professional 
use), the content of this regulation must also be related. 

Thank you for your contribution to environmental protection.

 

 

FCC Note 

This equipment has been tested and found to comply with the limits for a Class B digital device, 
pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection 
against harmful interference in a residential installation.  This equipment generates, uses and can 
radiate radio frequency energy and, if not installed and used in accordance with the instructions, 
may cause harmful interference to radio communications.  However, there is no guarantee that 
interference will not occur in a particular installation.  If this equipment does cause harmful 
interference to radio or television reception, which can be determined by turning the equipment off 
and on, the user is encouraged to try to correct the interference by one or more of the following 
measures: 
•   Reorient or relocate the receiving antenna. 
•   Increase the separation between the equipment and receiver. 
•   Connect the equipment into an outlet on a circuit different from that to which the receiver 
     is connected. 
•   Consult the dealer or an experienced radio/TV technician for help. 
 
This Class B digital apparatus complies with Canadian ICES-003. 
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. 
 

ISO 9001 Registration 

In 1994, Ohaus Corporation, USA, was awarded a certificate of registration to ISO 9001 by Bureau 
Veritus Quality International (BVQI), confirming that the Ohaus quality management system is 
compliant with the ISO 9001 standard’s requirements.  On May 15, 2003, Ohaus Corporation, 
USA, was re-registered to the ISO 9001:2000 standard. 

Summary of Contents for CS 2000

Page 1: ...Valor 2000 Series TM Instruction Manual 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com...

Page 2: ......

Page 3: ...hese safety precautions Verify that the AC Adapter input voltage matches the local AC power supply Do not immerse the scale in water or other liquids Do not operate the scale in hostile environments D...

Page 4: ...s Accepts the current setting on the display No Advances to the next menu or menu item Rejects the current setting on the display and advances to the next available setting 2 INSTALLATION 2 1 Package...

Page 5: ...rear leveling feet must be screwed in tightly to avoid entry of water inside the scale 2 4 Power 2 4 1 AC Power The AC adapter included may be used to power the scale when battery power is not availab...

Page 6: ...Fully Charged Flashing Green 70 100 Flashing Yellow 40 70 Flashing Red 0 40 The scale can operate for approximately 60 hours on a fully charged battery During battery operation the battery Indicator d...

Page 7: ...ht display The scale must be stable to accept zero operation 3 3 Manual Tare Place a container on the weighing pan then press ON 0 T Off The display will show a net value of 0 To clear the Tare value...

Page 8: ...ion power off the scale TABLE 4 1 CALIBRATION WEIGHTS Model Span Calibration weight kg User selectable Linearity Calibration weight kg Fixed V21PW3 1 2 3 2 3 V21PW6 2 4 6 4 6 V21PW15 5 10 15 10 15 4 2...

Page 9: ...ity calibration uses 3 calibration points The first calibration point is established with no weight on the scale The second calibration point is established at approximately half capacity The third ca...

Page 10: ...t kilograms ON or OFF When kg is lit press the Yes button to access the ON or OFF setting then press No to choose ON or OFF then Yes to accept the setting GRAM UNIT Set grams ON or OFF When g is lit p...

Page 11: ...Menu LEGAL FOR TRADE LFT MODE Set the legal for trade status to ON or OFF 4 9 END End menu item 5 LEGAL FOR TRADE 5 1 Settings Enter the menu to verify the settings and perform a calibration as explai...

Page 12: ...urchaser to ensure that all pertinent legal requirements are met Please contact your local weights and measures office for further details 5 3 Sealing The weights and measures official can apply a wir...

Page 13: ...Move scale to suitable location Relieve internal pressure by loosening rear leveling feet Unable to calibrate LFT Menu set to ON Unstable environment Incorrect calibration mass Set LFT menu to OFF see...

Page 14: ...g 3000 g x 0 5 g 6 lb x 0 001 lb 96 oz x 0 02 oz 6 kg x 0 001 kg 6000 g x 1 g 15 lb x 0 002 lb 240 oz x 0 05 oz 15 kg x 0 002 kg 15000 g x 2 g 30 lb x 0 005 lb 480 oz x 0 1 oz Maximum displayed resolu...

Page 15: ...EN 13 Valor 2000 Series Scales 7 2 Drawings and Dimensions 249 mm 9 8 in 229 mm 9 0 in 233 mm 9 2 in 184 mm 7 2 in 142 mm 5 6 in Figure 7 1 Valor 2000 Series Overall Dimensions...

Page 16: ...escriptive plate They may be put into service immediately Weighing Instruments to be verified in two stages have no green M metrology on the descriptive plate and bear one of the preceding identificat...

Page 17: ...e radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will n...

Page 18: ...to radioactive or corrosive materials has foreign material penetrating to the inside of the product or as a result of service or modification by other than Ohaus In lieu of a properly returned warrant...

Reviews: