1.9  RS232 INTERFACE CONNECTION 

The T31 has a bi-directional RS232 interface for communication with printers and computers. 
When communication is used, data can be output various ways, depending on PRINT menu 
settings. 

For RS232 cable connections, see Section 1.5.2, page 1-5. 

1.9.1  Setting Communications Parameters 

The T31 Indicator’s default communication parameters are baud rate 9600 bits per second 
(bps), 8 databits, no parity

,

 Handshake XON/XOFF, Stable Only Off, and Autoprint Off.   

To change these settings use the PRINT menu, as follows: 

1.  Press and hold 

TARE/Menu

 until 

C.A.L. 

appears.  Press 

No

.  

S.E.t.U.P

 appears.   

Press 

No

.  

r.E.A.d

 appears.  Press 

No

.  

M.O.d.E

 appears.  Press 

No.

  

U.N.I.t 

appears.  

Press 

No

.  

P.r.i.n.t 

appears.  Press 

Yes

rESEt 

appears.  Press 

No.

   

2. 

bAUd 

appears.  Press 

Yes

.  

 

3.  The default Baud rate setting, 

9600 

bps, appears.  To change the setting, press 

No.

  

The menu cycles to the next setting each time you press No: first 9600, then 300, 600, 
1200, 2400, 4800, and 9600 again.  Press Yes when the desired setting appears.  bAUd 
appears again.  Press No.   

4. 

PAritY 

appears.  Press 

Yes

.  The default Parity setting, 

NONE

, appears.  To change the setting, press 

No

.

 

5.  The menu cycles to the next setting each time you press No: 

first 7 Even, then 7 Odd, 7 None, and 8 None again.  Press 

Yes

 

to accept a setting.  

PAritY 

appears again.  Press 

No

.

  

 

6. 

StOP 

appears.  Press 

Yes

. The default Stop Bit setting, 

1

, appears.   

To change the setting, press 

No

.

 

7.  The menu toggles to the next setting each time you press No: 

first 1, then 2, then 1 again.  Press 

Yes

 when the desired setting 

appears.  

StOP 

appears again.  Press 

No

.

  

 

8. 

HANd 

appears.  Press 

Yes

.  The default Handshake setting, 

On-Off

 (Xon/Xoff), 

appears.  To change the setting, press 

No

.

 

9.  The menu toggles to the next setting each time you press No: first Off, 

then On-Off, then Off again.  Press 

Yes

 when the desired setting 

appears.  

HANd 

appears again.  Press 

No

.

  

 

10. 

StAbLE 

appears.  Press 

Yes

.  The Stable setting allows the Indicator to print values 

only when the stability criteria are met.  To choose 

ON

, press 

Yes

.  If you press 

No

Off

 

appears.  Press 

Yes 

to accept a setting.  Then 

StAbLE 

appears.  Press 

No

.  

 

11. 

A.Print

 appears.  Press 

Yes

.  Auto Print sets printing to occur each 

time stability criteria are met (

ON.StAB

), or at a defined interval 

(

INtEr

), or continuously (

CONt

).  The default setting is 

Off

.  Press 

No

 

until the preferred setting appears. Then press 

Yes

.  

A.Print

 appears.  

Press 

No

.  

INtEr

 appears.   

12. If 

INtEr 

was selected, use the 

INtEr 

sub-menu to set the interval, from 1 to 3600 

seconds.  Press 

No

 to advance, 

Back

 to regress, and 

Yes

 to accept a setting.  After you 

press 

Yes

INtEr 

appears again. Press 

No

 twice, then 

Yes

 when 

End

 appears, 

No

 when 

P.r.i.n.t 

appears, 

No

 again, and 

Yes

 when End appears again to exit menu mode.

 

3000 Series T31 Indicator Service Manual

  

1-11

 

Ohaus Corporation  www.ohaus.com

 

Summary of Contents for 3000 Series T31P

Page 1: ...SERVICE MANUAL 3000 Series T31 Indicators T31P T31XW Ohaus Corporation 19A Chapin Road P O Box 2033 Pine Brook NJ 07058 2033 973 377 9000...

Page 2: ......

Page 3: ...ate at the time of publication but Ohaus Corporation assumes no liability arising from the use or misuse of this material Reproduction of this material is strictly prohibited Material in this manual i...

Page 4: ......

Page 5: ...erface Commands 1 12 1 9 3 Output Format 1 12 1 10 Legal For Trade LFT 1 13 CHAPTER 2 TROUBLESHOOTING 2 1 Introduction 2 1 2 2 Visual Inspection 2 1 2 3 Diagnostic Guide 2 2 2 2 1 Diagnosis 2 2 CHAPTE...

Page 6: ...easing Decreasing Load Test 4 2 5 1 T31P Indicator Housing Internal Parts 5 3 5 2 T31XW Indicator Housing Internal Parts 5 5 A 1 Setup Calibration Values A 1 B 1 Geographical Adjustment Values B 1 LIS...

Page 7: ...and adjustments Chapter 5 Drawings and Parts Lists Contains exploded views of T31 Indicators identifying all serviceable components Before servicing the indicator you should be familiar with the Instr...

Page 8: ...Load Cell Simulator optional 3 Computer with RS232 Interface for testing the RS232 communications 4 RS232 Interface cable 5 Data Printer for use with RS232 communications 6 ESD work station or mat 1 3...

Page 9: ...5V DC Load Cell Drive Up to 4 x 350 ohm load cells Load Cell Input Sensitivity Up to 3mV V Stabilization Time Within 2 seconds Auto Zero Tracking Off 0 5 1 or 3 divisions Zeroing Range 2 or 100 of ca...

Page 10: ...housing by carefully pulling the top of the front housing forward Below is a diagram of the T31 s Main PCB with connectors jumpers terminals and switches indicated The Load Cell Cable connects to Term...

Page 11: ...to terminal block J7 See Figure 1 1 Re tighten the strain relief to ensure a water tight seal Strain Relief for RS232 cable Figure 1 4 Rear panel T31XW The RS232 wiring on the T31XW s Terminal J7 is...

Page 12: ...g the charging process The battery is protected against over charging and the Indicator can remain connected to the AC power line Connect AC power to the indicator and allow it to charge While the bat...

Page 13: ...r menu Menu Function Short Press Yes Accepts the current setting on the display No Advances to the next menu or menu item Rejects the current setting on the display and advances to the next available...

Page 14: ...isplayed menu Accepts the displayed setting and advances to the next menu item No Skips by the displayed menu Rejects the displayed setting or menu item and advances to the next available item Back Mo...

Page 15: ...ximately five minutes after stabilizing to room temperature 6 To abort calibration press the Exit button anytime during the calibration process 1 8 1 Geographical Adjustment Factor The Geographical Ad...

Page 16: ...displays the actual weight value 1 8 3 Linearity Calibration Linearity calibration uses three calibration points the first with no weight on the scale the second at approximately half capacity the thi...

Page 17: ...ing PAritY appears again Press No 6 StOP appears Press Yes The default Stop Bit setting 1 appears To change the setting press No 7 The menu toggles to the next setting each time you press No first 1 t...

Page 18: ...print name software revision and LFT ON if LFT is set ON Esc R Global reset to reset all menu settings to the original factory defaults NOTES Commands sent to the Indicator must be terminated with a c...

Page 19: ...E t U P appears Press Yes 3 rESEt appears Press No 4 LFt appears Press Yes 5 OFF appears Press Yes 6 LFt appears again Press No Continue to press No until END appears Press Yes Or simply press Exit a...

Page 20: ...CHAPTER 1 GETTING STARTED Ohaus Corporation www ohaus com 1 14 3000 Series T31 Indicator Service Manual...

Page 21: ...base damage from liquids cracks on corners which may suggest the unit was dropped 2 Open the Indicator by removing the four screws in the rear housing Be careful not to stretch the cables that connect...

Page 22: ...nts 2 2 1 Diagnosis 1 Isolate and identify the symptom 2 Refer to Table 2 1 Diagnostic Guide and locate the symptom 3 Follow the suggested remedies in the order they appear 4 Perform the indicated che...

Page 23: ...te Unstable environment Incorrect calibration mass Lock Calibration Menu set to On Lock switch on PCB is on LFT menu set to On Move the scale to suitable location Use correct calibration mass Set Lock...

Page 24: ...CB CAL E Calibration Error Calibration value outside allowable limits Repeat calibration using correct calibration weights LOW rEF In Pieces mode the average piece weight of the parts is small warning...

Page 25: ...e using a cloth dampened with a mild detergent 3 For the T31XW use approved cleaning solutions for the stainless steel Indicator housing and rinse with water CAUTION DO NOT USE CHEMICAL CLEANERS OR SO...

Page 26: ...al Block J7 See Figure 1 1 5 On the T31P Disconnect the battery Pull the horizontal white tab plug connecting the RS232 Interface to the PCB s Terminal J6 See Figure 1 1 6 On both models Pull the whit...

Page 27: ...using and disconnect the plastic ribbon cable that connects the Membrane Switch to the PCB 2 Carefully remove the old Function Label or Membrane Switch It is held in place with a strong adhesive 3 Cle...

Page 28: ...y s base 15 Lift out the Power Supply 16 Position the replacement Power Supply with the screw holes aligned 17 Position the grounding wire over the screw hold on the right side insert the screw and ti...

Page 29: ...acket that holds the Battery in place 7 Position the replacement Battery in the place of the old one 8 Reposition the bracket that holds the Battery in place and insert the four screws each with a was...

Page 30: ...CHAPTER 3 MAINTENANCE PROCEDURES Ohaus Corporation www ohaus com 3 6 3000 Series T31 Indicators Service Manual...

Page 31: ...t it to the Indicator power plug For the T31XW check that the power cord is not damaged 2 Plug the AC Adapter or power cord into a suitable power source 3 With the Indicator connected to an appropriat...

Page 32: ...n the Indicator Perform a Span Calibration with zero at the simulator s zero setting and 100 capacity at the simulator s 2 0 milli volt setting 2 Following calibration check that the Indicator s displ...

Page 33: ...hly checked after the replacement is made The balance MUST meet the parameters of all applicable specifications in this manual If further technical information is needed please contact your local Ohau...

Page 34: ...ARTS LISTS DIAGRAMS 5 1 3000 SERIES T31P INDICATOR HOUSING INTERNAL PARTS Figure 5 1 Series 3000 T31P Indicator Housing Internal Parts Ohaus Corporation www ohaus com 5 2 3000 Series T31 Indicator Ser...

Page 35: ...ability Label 2 Function Label 3 Top Housing 5 LCD Display with backlight 7 Main PCB 8 Battery Bracket Kit 9 Rechargeable Lead Acid Battery 10 Bottom Housing 11 Knobs Set of 2 12 Wall Mount Kit 13 Rub...

Page 36: ...RTS LISTS DIAGRAMS 5 2 3000 SERIES T31XW INDICATOR HOUSING INTERNAL PARTS Figure 5 1 Series 3000 T31XW Indicator Housing Internal Parts Ohaus Corporation www ohaus com 5 4 3000 Series T31 Indicator Se...

Page 37: ...with Gasket 5 LCD Display with backlight 7 Main PCB 10 Bottom Housing 11 Knobs with seals Set of 2 12 Wall Mount Kit 14 Cable Kit 15 Power Supply PCB 16 Power Supply Cover 17 Cable Fitting for AC Powe...

Page 38: ...CHAPTER 5 PARTS LISTS DIAGRAMS Ohaus Corporation www ohaus com 5 6 3000 Series T31 Indicator Service Manual...

Page 39: ...75 100 120 150 75 150 200 0 01 0 02 0 05 0 1 0 2 0 05 0 1 0 2 5 10 15 20 25 30 40 50 60 75 100 120 150 200 100 200 250 0 05 0 1 0 2 0 05 0 1 0 2 5 10 15 20 25 30 40 50 60 75 100 120 150 200 250 120 2...

Page 40: ...6000 2500 5000 7500 0 5 1 2 5 2 5 5 10 15 20 25 30 40 50 60 75 100 120 150 200 250 300 400 500 600 750 1000 1200 1500 2000 2500 3000 5000 6000 7500 3000 7500 10000 0 5 1 2 5 10 2 5 10 5 10 15 20 25 30...

Page 41: ...17 17 18 18 19 19 20 20 21 21 22 22 04 05 05 06 06 07 07 08 08 09 09 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 20 21 21 22 04 04 05 05 06 06 07 07 08 08 09 09 10 10 11 11 12 12 13...

Page 42: ...66 24 67 57 67 57 69 35 69 35 71 21 71 21 73 16 73 16 75 24 75 24 77 52 77 52 80 56 80 56 85 45 85 45 90 00 23 23 24 24 25 25 26 26 27 27 28 28 29 29 30 30 31 22 23 23 24 24 25 25 26 26 27 27 28 28 2...

Page 43: ......

Page 44: ...80252598 P N 80252598 SERVICE MANUAL 3000 SERIES T31 INDICATORS...