7.

Place the Scale Plate on the four vertical Support Posts, with the solid weld stud

resting on the left front Post (with the two Lock Nuts).  Hook the Mass Hanger Assembly

on the Ring that is located at the right end of the Beam.

8.

Unpack the Slotted Masses from the corrugated box and place them on the Mass Rack.

USING THE BALANCE (ZEROING)

1.

Move all four Poises to their ZERO positions at the ex-

treme left end of travel.  The Rear Poise is equipped

with a pin that will position it accurately in the notches.

2.

If the Balance does not come to rest exactly at zero, it

can be rebalanced by using the two knurled, brass Ad-

justment Nuts of the Balance Compensator Assembly.

When correct balance has been restored, be sure to

lock the Balance Nuts against each other to prevent

movement.

WEIGHING

Net Weight can be determined rapidly by following these steps:

1.

Counterbalance the EMPTY container with the two

Tare Poises.  Loosen the Thumb Screw of the larger

Tare Poise and move both Poises to the right.  The

larger Tare Poise is used for 

COARSE

 balancing and

then is locked with the thumb screw.  The smaller Tare

Poise is used for 

FINE

 balancing.  It is spring-loaded

to protect against accidental movement.

2.

Place the specimen as near the center of the Scale

Plate as possible.

3.

Move the Rear Poise to the right until it is in the first notch that will cause the Beam to

DROP below the Balance Indicator at the pointer end of the beam.  Move it to the left

one notch and the Beam will RISE.

4.

Move the Front Poise to the right until balance is obtained.

5.

Read the weight of the specimen directly by adding the values indicated by the Poises.

6.

If the Rear Poise can be moved to the extreme right notch but it does not cause the

Beam to DROP, return both the Front and Rear Poises to ZERO and add Slotted

Attachment Masses to the Mass Hanger Assembly.  Add sufficient masses to cause

the Beam to DROP below the Balance Indicator at the pointer end of the Beam.

Remove the smallest (lightest) mass and follow Steps 3, 4 and 5.  Add the total value

of the Attachment Masses on the Mass Hanger Assembly to the values indicated by

the positions of the two poises to obtain weight of the specimen.

CARE AND MAINTENANCE

The following practices will ensure that your Heavy Duty Solution Balance will give years of

satisfactory and trouble-free service.

1.

When not in use, remove any load from the Scale Plate and place the Slotted Masses

on the Mass Rack.  Slide one of the Poises away from ZERO, so that the Balance is

not in equilibrium.  This will stop the Balance from oscillating and prevent unnec-

essary wear.

2.

Use and store the Balance in places that are free from vibration, which can cause

unnecessary wear.

3.

Keep the Balance clean at all times, being particularly careful to not let dirt accumu-

late in the vicinity of the bearings.  Never use oil, or any lubricant, on the knives or

bearings.  Lubrication will reduce the readability and accuracy of the Balance.

4.

Occasionally, it will be necessary to clean accumulated debris from the Magnet Faces

in the base of the Trig Loop Post Assembly.  Insert a piece of adhesive-backed tape

into the Magnet slot that the aluminum Damper Vane enters.  Press the tape against

the Magnet Face with a ruler or a similar thin strip.  Dirt or magnetic particles will

adhere to the tape when it is removed and the Damper Vane will be able to oscillate

freely.

ACCESSORIES

Description
Slotted attachment Mass Set

Ohaus Part No. 127-MO

 1-10kg, 1-5kg, 2-2kg, 1-1kg

Stainless Steel Scoop

Ohaus Part No.80250954

17.2 x 11 x 3.4/
44 x 28 x 8.5

Balance Compensator

LIMITED WARRANTY

Ohaus products are warranted against defects in materials and workmanship from the date of delivery

through the duration of the warranty period. During the warranty period Ohaus will repair, or, at its option,

replace any component(s) that proves to be defective at no charge, provided that the product is returned,

freight prepaid, to Ohaus.
This warranty does not apply if the product has been damaged by accident or misuse, exposed to

radioactive or corrosive materials, has foreign material penetrating to the inside of the product, or as a

result of service or modification by other than Ohaus. The warranty period shall begin at the date of

installation, or three months from shipment to the buyer, whichever occurs first.  A properly completed

Warranty Registration Card must be received by Ohaus within 30 days from date of purchase to initiate

coverage under the warranty.  No other express or implied warranty is given by Ohaus Corporation.

Ohaus Corporation shall not be liable for any consequential damages.
As warranty legislation differs from state to state and country to country, please contact Ohaus or your

local Ohaus dealer for further details.

SPECIFICATIONS

Model  Weighing Beam weighing  Readability   Tare    Platform type

      Dimensions

    Carton size

         Shipping

              capacity       range

   and size (in/cm)              W x H x D  (in/cm)

   W x H x D (in/cm)

      weight(lb/kg)

1119D    20kg

     1100g

    1g

 2270g   Stainless steel 11/27.9          34 x 11 x 11/                      36 x 12 x 10/

           44/19.9

   86.36 x 27.94 x 27.94           91.44 x 30.48 x 25.4

Tare Poise