background image

U S E R   M A N U A L   D A Y C O R ® S U P E R B  

 9 

To switch to manual exposure, press on the exposure function-key and as a result an 

indication of the exposure value appears. Using the up and down arrows the exposure 

values are changed. The range of exposure is from 1/10000 down to 1/80 and further 

to field modes of 2, 4, 6 and 8 integrated frames.    

When aiming against a strong light source or against the sun, never exceed exposure of 

1/125 or the visible camera might get damaged. 

 

Status Display 

 

By default the status line is displayed. The status line includes information about the 

selected functions and the date and time.  It is recommended to  keep the status 

information  while recording. This data is valuable for keeping logs, follow up, 

documentation etc.  

To turn off press on the OSD key . 

LCD Back Light 

 

The LCD back light can be adjusted by the dedicated knob on the LCD. Note that the 

brightness does not affect the brightness of the video output.  

 

 

Zoom 

 
Visible Zooming 

Visible zoom values are X25 optical and X12 digital. 

When using the visible zoom, the UV camera shows only the visible channel.  The 

combined mode, v UV, will reappear upon exiting zooming. 

  

Rapid Visible Zoom  

The camera is equipped with a rapid visible zoom mechanism, which means that the 

switch from normal to max optical zoom and backwards takes 1 second by a 

continuous key press or release. 

Digital UV Zoom 

When using the digital zoom the camera remains in combined mode, v UV and 

the corona is transparent. Zooming values are X2 or X4. Activating this function 

brings up the X2 zoom To toggle between the X4 and X2 zoom use the up/down 

arrows. 

Summary of Contents for daycor superb

Page 1: ...1 DayCor Revision June 2011 Ofil Ltd User s Guide...

Page 2: ...POB 4016 Nes Ziona 74140 Israel 16 Einstein Street Weizmann Science Park Nes Ziona Israel 74000 www ofilsystems com ofil ofilsystems com Tel 972 8 940 7953 Fax 972 8 940 7873 USA Toll free 1 866 27986...

Page 3: ...G 6 UV GAIN 6 LI LONG INTEGRATION 7 COUNTING 7 EXPOSURE 8 STATUS DISPLAY 9 LCD BACK LIGHT 9 ZOOM 9 VIDEO RECORDING 10 STILLS RECORDING 10 FIRST TRYOUT 10 CHAPTER 3 11 INSPECTION TIPS 11 HANDLING NON C...

Page 4: ...just the shoulder straps to fit your body by fastening the straps 3 Fasten the front pad 4 Lean the camera against the front pad Use the grooves to adjust the viewing angle of the camera 5 hook the su...

Page 5: ...ation and for report generation Here is an example of a status line with and without counting Option 1 with counting COMBINE AF GAIN 180 COUNTER 10000 Option 2 without counting COMBINE AF GAIN 180 LI...

Page 6: ...e focus scale is also used when the camera needs to be recalibrated a procedure that can easily be performed by the camera operator special instructions When to use manual focus When Corona is out of...

Page 7: ...m UV signals can be removed while the repetitive signal although decreasing in size will still be visible on the screen More in Chapter 3 Counting The counting function provides an indication of the c...

Page 8: ...spots that were overlapping in the focused mode and were counted as a single spot 4 The displayed counting is an average of the last 4 display values it is therefore necessary to wait 4 successive di...

Page 9: ...or keeping logs follow up documentation etc To turn off press on the OSD key LCD Back Light The LCD back light can be adjusted by the dedicated knob on the LCD Note that the brightness does not affect...

Page 10: ...folders that are created automatically by date and time Use arrows to navigate withing a folder Display an image using the F1 Step back using F2 Leave playback by pressing any other button First tryo...

Page 11: ...r the feeling as if the camera is not solar blind Although those random UV spots do not harm the camera it is recommended not to look for a long time directly on a welding machine with the camera A st...

Page 12: ...the UV channel of the DayCor Superb camera turns into a slow response instrument If the camera moves relative to the UV source the UV image will be smeared When recording while operating in the LI mo...

Page 13: ...center or off center Or else consult the manufacturer Focus If the camera needs to be recalibrated ask the manufacturer for the procedure to be performed by the camera operator To check alignment of t...

Reviews: