1. INSTRUMENT DESCRIPTION 

Mechanical dial-type level indicators have been designed to measure the level of fluids in small, medium and large 
vessels. 
The  main  assets  are:  great  reliability  and  sturdiness,  quick  and  easy  installation  and  easy-readable  level  due  to  the  dial 
size. 
The instrument does not require any power supply. 

 

2. MODEL IDENTIFICATION 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

TLQ.

TRANSMITTER

Hart Transmitter

Hart/Exia Transmitter

Exia IIC T6 transmitter

No trasmitter

Std. Transmitter

TX

T0

TS
TE

GAS thread

NPT thread

UNI flange

ANSI flange

TG

TN
FU
FA

3

Aisi 316

DIN flange

Carb. Steel

Aisi 316

CONN. MATERIAL

A

J

FLOAT

FD

MEASUR. RANGE

03
05
10

0-3 m single scale
0-5 m double scale
0-10 m double scale
0-20 m double scale

4
5
6

brass

O

J

EXTENSION MATERIAL

PROCESS CONNECTION

1

Special float

S  

up to 5 m

up to 20 m

20

AISI 316L Ø85x110mm

AISI 316L Ø105mm
AISI 316L Ø140mm
AISI 316L Ø300mm

TH

1-2 Exd IIC T6 alarms

1-4 NPN proximity alarms

ALARMS

No alarms

CS1-4

CE1-2 

1-4 Standard alarms

C0

T0

CP1-4 

CN1-4 

1-4 PNP proximity alarms

C0

XX

VERSION

CR1-4 

1-4 NAMUR proximity alarms

S

N0N-STANDARD VERSION

03

O

TG

A

1

Summary of Contents for TLQ Series

Page 1: ...not require any power supply 2 MODEL IDENTIFICATION TLQ TRANSMITTER Hart Transmitter Hart Exia Transmitter Exia IIC T6 transmitter No trasmitter Std Transmitter TX T0 TS TE GAS thread NPT thread UNI...

Page 2: ...t 4 to move by magnetic coupling The movement of the rope which is wound around a pulley 6 with a return device causes the hands of the clockworks assembly to move and indicate the fluid s level in th...

Page 3: ...een the magnets 4 Release the wire very slowly It will wind round the pulley until it gets tightened 5 Screw the instrument s neck onto the coupling flange 6 Remove the round cover opposite to the poi...

Page 4: ...made through cable entrances or tube piping in compliance with the EN 60079 14 standard The cable entrance shall not affect the specific properties of the protection method as indicated in the EN 600...

Page 5: ...y value 10 35 Volt for standard models and d10 28 Volt for explosion proof models The maximum load is given by the following formula R LOAD V SUPPLY 8 0 023 The instrument shall never work close to st...

Page 6: ...INTENANCE Mechanical dial type level indicators do not generally require any scheduled maintenance Periodically check once every six months approximately that the rod and the float are clean and the i...

Page 7: ...DRAWING Dimensioning values required C Connections L Range E Extension F Float D Extension connection 9 SPARE PARTS A THREADED THREADED F THREADED THREADED FLANGED FLANGED TLQ H TLQ S 160 220 UNI DN 2...

Page 8: ...ons in force All metal parts after removal of seals and gaskets special protective coatings requested by the customer and all other plastic parts can be recycled 12 GUARANTEE All level indicators are...

Page 9: ...clean and free from dust or deposits Otherwise OFFICINE OROBICHE reserves the right not to carry out the servicing and return the instrument to the sender FINAL REMARKS Each instrument is supplied ful...

Reviews: