DECLARATION OF COMPLIANCE

The manufacturer declares that the appliances are compliant with the prescriptions of the 

EEC norm 90/396. The installation must be done observing the norms in force particularly 

concerning room ventilation and discharging gas emissions.

N.B.: 

The manufacturer declines any responsibility for direct or indirect damage caused 

by improper or incorrect installation, alterations, maintenance or use of the appliance, as 

in all the other cases considered in the items of our sales conditions.

INSTRUCTIONS FOR INSTALLATION

When fitting, the appliance must be levelled using a spirit level; slight differences of level 

can be adjusted by screwing or unscrewing the adjustable feet. The main switch or the so-

cket must be near the appliance and easily accessibile.

It is advisable to place the appliance under an extractor hood so that steam is extracted 

rapidly. If the appliance is placed near walls, dividing panels, kitchen furniture, decorative 

finishings, etc., these should be in flameproof material; otherwise it is necessary to cover 

them with non-flammable material.

Above all, it is necessary to ensure that the fire prevention norms are observed

LAWS, TECHNICAL RULES AND NORMS

Installation must be carried out observing the following norms:

- Safety prescription in force

- Installation prescription, ECI norms.
The installation, starting up and maintenance of the appliance must be carried out by 

qualified personnel. All operations done when installing must be carried out observing the 

norms in force.

The manufacturer declines all responsibility in the event of incorrect functioning due to 

TECHNICAL ELECTRICAL DATA TABL

E

TRANSFORMATION

MODELS

DIMENSIONS

 cm

POWER SUPPLY Power max 

kW

Absorbition 

max A

Power supply 

cable

PVS4

40 x 70 x 29h

400V 2N 50/60Hz

5

10,9

4 x 1.5 mm²

PVS8

40 x 70 x 29h

400V 3N 50/60 Hz

10

21,7

5 x 2.5 mm²

MODELS

POWER SUPPLY Power max 

kW

Absorbition 

max A

Power supply 

cable

PVS4

230Vac 50/60Hz

5 kW

21,74 A

3 x 2,5 

mm²

PVS8

230Vac3 50/60Hz

10 kW

28,76 A

4 x 4 

mm²

Summary of Contents for PVS4

Page 1: ...PVS4 PVS8 ELECTRICAL GLASS CERAMIC COOKING TOP FOR RESIDENTIAL AND PROFESSIONAL USE INSTRUCTIONS for installation and use...

Page 2: ...appliance s maximum power consumption The use of adapters multiple power boards and extension cords is not recommended 8 When not in use switch off the general power supply to the appliance and close...

Page 3: ...3 Officine Gullo A Data Plate B Electrical connection FIG A...

Page 4: ...nes 2 Piastra Kochplatte Plaque Hotplate Placa 3 Regolatore di energia Energie regler Regolateur de energie Energy regulator Regolador de energia 4 Spia bianca wei e Kontroll Leuchte T moin blanc Whit...

Page 5: ...laque Hotplate Placa 3 Regolatore di energia Energie regler Regolateur de energie Energy regulator Regolador de energia 4 Spia bianca wei e Kontroll Leuchte T moin blanc White light Luz indicadora bla...

Page 6: ...6 Officine Gullo...

Page 7: ...S TECHNICAL RULES AND NORMS 8 ELECTRIC CONNECTION 9 EQUIPOTENTIAL 9 STARTING UP 9 INSTRUCTIONS FOR USE 9 TURNING ON 10 CLEANING AND MAINTENANCE 11 PROCEDURE TO FOLLOW IF THE APPLIANCE IS NOT GOING TO...

Page 8: ...is placed near walls dividing panels kitchen furniture decorative finishings etc these should be in flameproof material otherwise it is necessary to cover them with non flammable material Above all i...

Page 9: ...have the following characteristics it must be at least type H05RN F and must have an adequate section for the power of the appliance see technical data table EQUIPOTENTIAL The appliance must be connec...

Page 10: ...sed be careful not to slide them on the crystal in order to avoid any scratches Make sure that the bottom of the pans has been dried well before placing them on the top avoid banging the crystal espec...

Page 11: ...e brass with an artificial patina The antique finish of the surface is the result of natural oxidation that has simply been accelerated All the natural antique finish brass surfaces can be cleaned wit...

Page 12: ...and where necessary extra fine steel wool or extra thin sandpaper PROCEDURE TO FOLLOW IF THE APPLIANCE IS NOT GOING TO BE USED FOR SOME TIME Clean and dry the appliance carefully according to the inst...

Page 13: ...13 Officine Gullo...

Page 14: ...14 Officine Gullo...

Page 15: ...15 Officine Gullo...

Page 16: ...WWW OFFICINEGULLO COM V 2 1 10 17 OFFICINE GULLO S R L via della Torricella 29 50012 Antella Bagno a Ripoli FI Tel 39 055 6560324 621807 Fax 39 055 620670 info officinegullo com en INTERNATIONAL...

Reviews: