Officine Gullo
6
3
SCHEMA ELETTRICO FORNO ELETTRICO MULTIFUNZIONALE
SCHALTPLAN MULTIFUNKTIONS-ELEKTROOFEN
SCHEMA ELECTRIQUE FOUR ÉLECTRIQUE A FONCTIONS MULTIPLES
MULTIFUNCTIONS ELECTRIC OVEN WIRING DIAGRAM
ESQUEMA ELÉCTRICO HORNO ELÉCTRICO MULTIFUNCIONAL
1
Selettore
Umschalter
Commuateur
Commutator
Conmutador
2
Lampada forno
Backofen-Beleuchtung Ampoule four
Oven light
Luz horno
3
Morsettiera Klemm-leiste Bornier
Junction-box Tablero de bornes
4
Motoventilatore Ventilator
Motoventilateur Fan
Ventilador
5 RS
Resistenza superiore
Ober-Heizkörper
Backofen
Résistance supérieure
Upper heating element Resistencia superior
5 RG
Resistenza (grill)
Heizkörper Grill
Backofen
Résistance (grill)
Element (grill)
Resistencia (grill)
5 RI
Resistenza inferiore
Unter-Heizkörper
Backofen
Résistance inférieure
Bottom heating element Resistencia inferior
5 RC
Resistenza circolare
Spiral-Heizkörper
Résistance circulaire
Round heating element Resistencia crcular
6
Spia bianca
weiße Kontroll-Leuchte Témoin blanc
White light
Luz indicadora blanca
7
Spia verde
grüne Kontroll-Leuchte Témoin vert
Green light
Luz indicadora verde
8
Timer Timer Timer Timer Timer
9
Termostato Thermostat Thermostat Thermostat Termostato
1. Commutator
2. Oven light
3. Junction box
4. Fan
5. RS-Upper Heating element / RG -
Element grill / RI - Bottom heating
element / RC - Round Heating
element
6. White light
7. Green light
8. Timer
9. Thermostat
Fig. B
ELECTRIC OVEN WIRING DIAGRAM
7
Officine Gullo
DECLARATION OF COMPLIANCE
This appliance is manufactured by OFFICINE GULLO S.r.l
Headquarters and factory
Via Della Torricella 29, Antella, Bagno a Ripoli
50012 Florence - Italy
Tel. +39 055 65 60 3324
+39 055 62 18 07
officinegullo.com | [email protected]
The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect
installation, alterations, maintenance or use of the appliance, as in all the other cases considered in the items of our
sales conditions.
INSTRUCTIONS FOR INSTALLATION
The data plate is on the front of the side (see diagram in electric connection item) and has all the data necessary
for the connection.
INSTALLATION
When fitting, the appliance must be levelled using a spirit level; slight differences of level can be adjusted by
screwing or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily
accessible. It is advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the
appliance is placed near walls, dividing panels, kitchen furniture, decorative finishing, etc. , these should be in
flameproof material; otherwise it is necessary to cover them with non-flammable material. Above all, it is necessary
to ensure that the fire prevention norms are observed.
Attention!
This appliance has been produced for use as part of a battery. If used singly, it will be necessary to keep
it at least 10cm away from the adjacent walls.
The manufacturer declines all responsibility in the event of incorrect functioning due to wrong installation or installation
which does not comply with the norms.
LAWS, TECHNICAL RULES AND NORMS
Installation must be carried out observing the following norms:
- Safety prescription in force
- Installation prescription, in force.
The installation, starting up and maintenance of the appliance must be carried out by qualified personnel. All
operations done when installing must be carried out observing the norms in force. The manufacturer declines all
responsibility in the event of incorrect functioning due to wrong installation or installation which does not comply
with the norms.
Attention!
In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening
of at least 3 mm.