Officine Gullo CVCS4EM Instructions For Installation And Use Manual Download Page 6

6

Officine Gullo 

FIG.A

ELECTRICAL  / SCHEME

The installation of this appliance must conform with all applicable local codes. 
In the absence of local codes, the installation must conform to the latest level of the Na-
tional Electric Code, ANSI/NFPA 70.

If the electrical supply is not turned on or is interrupted the appliance will not operate. The 
applicable wiring diagram for this appliance is below. The circuit where you wire your ap-
pliance to must be grounded and polarized. We recommend the circuit for your appliance 

be a non-GCFI dedicated line.

CVCS4EM

TABELLA DATI TECNICI CP-74EM CP-74ET CP-78ET 230Vac 7,8 kW 15,6 kW.doc 

FIG.A 

SCHEMA ELETTRICO , SCHALTPLAN, SCHEMA ELECTRIQUE , WIRING 

DIAGRAM, ESQUEMA ELECTRICO 

549025300 M00_00 , 549021400 M00_00 

230V~ 50/60Hz  

230V~3 50/60Hz 

1-2

Commutatore Schalter 

Commutateur Commutator  Conmutador 

Morsettiera  Klemmleiste 

Bornier 

Junction-box Tablero de bornes 

Morsettiera 
commutazione 

Switching 
Klemmenblock 

Bornier de commutation  Switching terminal 

block 

Tablero de bornes de 
conmutación 

Resistenze  Widerstände 

Résistances Elements 

Resistencias 

Spia bianca 

weiße Kontroll-Leuchte 

Témoin blanc 

White light 

Luz indicadora blanca 

Spia verde 

grüne Kontroll-Leuchte 

Témoin vert 

Green light 

Luz indicadora verde 

Termostato sicurezza 
Teleruttore 

Sicherheits-thermostat 

Thermostat de sécurité 

Safety Thermostat 

Termostato seguridad 

MODELLI 

MODELLE 
MODELES 

MODELS 

MODELOS 

Morsettiera Nr.1 

Klemm-leiste Nr.1 

Bornier Nr.1 

Junction-box Nr.1 

Tablero de bornes Nr.1

CP-74ET 

FIG.A 

CP-78ET 

FIG.A + FIG.A 

interruzione pagina

1.  Commutator
2.  Commutator
3.  Junction box
4.  Switching terminal block
5. 

Elements

6.  White light
7.  Green light
8.  Safety Thermostat

Summary of Contents for CVCS4EM

Page 1: ...x INSTRUCTIONS for installation and use PASTA COOKER FOR RESIDENTIAL AND PROFESSIONAL USE CVCS4EM ...

Page 2: ......

Page 3: ...TABLE OF CONTENTS WARNINGS CAUTION 4 SAFETY INSTRUCTIONS 5 ELECTRICAL SCHEME 6 INSTALLATION INTRUCTIONS 7 USE AND MAINTENANCE INSTRUCTIONS 9 CLEANING AND CARE INSTRUCTIONS 10 ...

Page 4: ... doubt please consult a qualified electrician 5 When not in use for extended periods switch off the general power supply to the appliance and close the gas supply valve 6 Do not obstruct the appliance s cooling or heat dissipation vents 7 The appliance must be used only for the purposes for which it has been expressly designed cooking All other uses such as the heating of a room are considered ina...

Page 5: ...A check before each use to determine that no hazardous materials are in the area is recommended 6 Children should not be left alone or unattended in the kitchen while the appliance is in use 7 This appliance should not be operated without a properly sized and operational ventilation hood 8 The ventilation and flue ways of this appliance must remain unobstructed at all times 9 Do not store items of...

Page 6: ...DIAGRAM ESQUEMA ELECTRICO 549025300 M00_00 549021400 M00_00 230V 50 60Hz 230V 3 50 60Hz 1 2 Commutatore Schalter Commutateur Commutator Conmutador 3 Morsettiera Klemmleiste Bornier Junction box Tablero de bornes 4 Morsettiera commutazione Switching Klemmenblock Bornier de commutation Switching terminal block Tablero de bornes de conmutación 5 Resistenze Widerstände Résistances Elements Resistencia...

Page 7: ...ICAL INSTALLATION The data plate is on the front panel see diagram in electric connection item and has all the data necessary for the connection When fitting the appliance must be levelled using a spirit level slight differences of level can be adjusted by screwing or unscrewing the adjustable feet The main switch or the socket must be near the appliance and easily accessibile It is advisable to p...

Page 8: ...e connection cable through the cable blocker connect the conductor wires to the corresponding terminals in the junction box and fix them into place Block the cable with the cable blocker and reassemble the bottom panel The earth wire must be longer than the others so that if the cable blocker should break it will disconnect after the tension wires The connection cable must have an adequate section...

Page 9: ... Cl not more than 10 ppm acceptable value to avoid damaging the internal steel elements pH over 7 Electrical conductivity 50 to 2000 μS cm 20 C TURNING ON Check that the water drainage tap is turned off 1 When powering the device the red light flashes briefly for about second 2 In the absence of water in the tank the red light keeps flashing 3a Turn on the tap to load the tank to the desired level...

Page 10: ... steady red light To reset the alarm condition after removing the fault that caused the intervention broken or disconnected level probes problems with the water supply drain valve open the system must be turned OFF ON CARE AND CLEANING INSTRUCTIONS CLEANING AND MAINTENANCE Attention During cleaning do not wash the external parts of the appliance with direct sprays of water or with high pressure Af...

Page 11: ...e chromium plated brass details in order to avoid spoiling the beauty of the chrome with an artificial patina All the chromed surfaces should be clean as needed with a warm water and mild soap and a soft cloth or micro fiber Do not use abrasive pads CLEANING SATIN FINISH NICKEL PLATED BRASS SURFACES No synthetic varnishes have been used to obtain the special nickel plating on the satin finish nick...

Page 12: ...WWW OFFICINEGULLO COM V 2 3 11 17 OFFICINE GULLO S R L via della Torricella 29 50012 Antella Bagno a Ripoli FI Tel 39 055 6560324 621807 Fax 39 055 620670 info officinegullo com us ...

Reviews: