Offgridtec PSI-PRO Inverter
6 Troubleshooting
Konto Sparkasse Rottal-Inn
Konto: 10188985
BLZ: 74351430
IBAN: DE69743514300010188985
BIC: BYLADEM1EGF (Eggenfelden)
Sitz und Amtsgericht
HRB: 9179 Registergericht Landshut
Steuernummer: 141/134/30045
Ust-IdNr: DE287111500
Gerichtsstand: Mühldorf am Inn
6
Troubleshooting
A high voltage occurs in the inverter. DO NOT attempt to repair or maintain the inverter
itself; This can cause an electric shock.
Lcd
Error
Reasons
Troubleshooting
The blue
indicator
flashes
slowly.
Buzzer
beeps.
The DC input voltage is
too low.
Check that the DC input
voltage is lower than
10.8/21.6V.
The inverter resumes work
after the input voltagehas been
e-handed.
Blue
indicator
flashes
quickly.
Buzzer
beeps.
The DC input voltage
is too high
Check that the DC input voltage is
higher than 16/32V.
The inverter resumes work after the
working voltage range has been
reached again.
The red
indicator
flashes
quickly.
Buzzer
beeps.
Overload
Reduce rated power at the AC
output and restart the inverter.
Red
indicators
flashing
quickly.
Buzzer
beeps.
Load short circuit
Check the connection of the
loads carefully.
Delete the short-circuit errors
and restart the inverter.