background image

User Manual

When displaying the TARIFF 1 , press and hold the [Set] button for 3 seconds to enter the rate setting.
Press [+] or [-] to select between TARIFF1 and Dual Tariff.
Press the [OK] key to confirm your choice and enter the next setting menu.

If your choice is single rate/tariff, 

Press [+] or [-] to select the setting data.
Press the [History] key to switch between digit positions.
Press the [OK] key to confirm the current setting.

If your choice is dual rate/tariff, 

Press [+] or [-] to select the setting data.
Press the [History] key to switch between digit positions.
Press the [OK] key to confirm the current setting and please refer to following example

{Example: Setting Double Rate}

Rate 1:   1.00 $/KWh   starting from 8:00; 
Rate 2:   0.50 $/KWh   Starting from23:00, then:
During 8: 00~23:00 at a unit price of $1/Kwh.
During 23:00~8:00, at a unit price of $0.5/Kwh.

Default value: 0.86 KgCO

2

/KWh.

When the carbon emission unit is displayed, press and hold the [Set] button for 3 seconds to enter the 
carbon emission setting.
Press [+] or [-] to select the setting value.
Press the [History] key to switch between digit positions.
Press the [OK] key to save the current settings and exit.

Carbon emission settings

4.Data Reset:

Press the [+] and [-] keys simultaneously for 3 seconds, and the display will flash,
Press the [Set] button again for 3 seconds to reset for factory setting and clear the data.

5.Technical parameters:

5.1 Display Range
   Total power consumption time display range: 0 minutes, 0 seconds -9999 days
      Power display range:                      0.000-9999W
      Voltage display range:                    0.000-9999V
      Current display range:                    0.000-9999A
      Power data display range:              0.000-9999KWh
5.2 Working conditions:
      Working voltage: 230VAC/50HZ
      Max current:       16A
      Max power:         3680W
5.3 Warning:
For indoor use only and keep out of water!
Do not exceed the max power!

Total carbon emissions

1

4

General Description:

1.Real-Time Display

Press the [Energy] button repeatedly to display in sequence as following:

Power (W): Display real-time power.

AC Voltage(V)

Frequency(Hz)

Current

(

A

)

Power factor: 1.00 means resistive load, < 1 means inductive load.

Maximum power: The maximum instantaneous power of overall 

connection.

Maximum current: The maximum instantaneous current of overall 

connection.

                                                      Overload alarm wattage: Defaults to 3680W. When the actual 
                                                      power exceeds this value, "Overload" flashes.
   
   How to DIY set the Overload alarm wattage

When the overload alarm wattage is displayed, press and hold the [Energy] button for 3 seconds 
to set the overload alarm value.
Press the [+] or [-] keys to adjust the number.
Press the [History] key to switch between digit positions.
Press the [OK] key to confirm and exit the settings.

   

Plug the power meter into a household 230 VAC wall-outlet, and connect with appliances such as 
refrigerators, televisions, air conditioners, etc. or connect with microinverter Schuko plug into the 
power meter. The power meter displays parameters such as power (watts), electricity consumption 
(kilowatt hours), and electricity bill , and can visually display the electricity consumption/generation  
for the past 7 days, 7 weeks, and 7 months.

OVERLOAD

TOTAL

Reviews: