A - GENERAL INFORMATION
A
- 10
CITOARC AP 217/ AP 225
3. TECHNICAL SPECIFICATIONS
CITOARC AP 217
REF. SA 0408-2917
CITOARC AP 225
REF. SA 0408-2929
PRIMARY
Number of phases / frequency
3 ~/50 HZ
3 ~/50 HZ
Power supply
r
10 %
380/400/415 V
380/400/415 V
Current maxi drain
20.5 A / 400 V
20.5 A / 400 V
Maximum output
14.2 KVA
14.2 KVA
SECONDARY
Number of gamme
1
2
Intensity
45
30 / 60
Duty factor
at
t=40°C
at
t=25°C
at
t=40°C
at
t=25°C
Gamme 1
40 %
45 %
100 %
100 %
Gamme 2
-
-
40 %
45 %
Gamme 3
-
-
-
-
Size (L x W x h)
615 x 530 x 885
615 x 530 x 885
Net weight
85 kg
85 kg
Packaged weight
105 kg
105 kg
Degree of protection
IP 23
IP 23
Insulation class
H
H
Standard
EN 60974-1
EN 50192
EN 60974-1
EN 50192
Degrees of protection provided by the covering
Code letter
IP
Equipment protection
First number
2
Against the penetration of solid foreign bodies with
t
12,5 mm
1
Against the penetration of vertical drops of water with harmful
effects
Second number
3
Against the penetration of rain (inclined up to 60° in relation to
the vertical) with harmful effects
Summary of Contents for citoarc AP 217
Page 4: ...2 CITOARC AP 217 AP 225 ...
Page 15: ...B STARTING UP CITOARC AP 217 AP 225 B 13 ...
Page 19: ...C INSTRUCTIONS FOR USE CITOARC AP 217 AP 225 C 17 ...
Page 24: ...D MAINTENANCE D 22 CITOARC AP 217 AP 225 4 ELECTRICAL DIAGRAMS See diagram opposite ...
Page 25: ...D MAINTENANCE CITOARC AP 217 AP 225 D 23 5 INSTALLATION OF COMPONENTS ...