background image

5

Operating Instructions and Parts Manual 

24815

SANDBLAST BENCH TOP CABINET

5/19

2019 OEMTOOLS

MAINTENANCE

Before use, check to ensure that all parts are service-
able, including the air inlet hose, rubber gloves and 
abrasive pick-up.

Ensure the air vent foam filter is in place.

The swivel clamps, securing the lid, must be secure so 
as not to allow the lid to open during operation. The 
build up of air pressure within the cabinet could force 
the lid open, allowing abrasive to escape. This is not 
only wasteful, but could be a health hazard.

Ensure the filters are serviceable and seated correctly.

Ensure you comply with all precautions regarding the 
use of compressed air, and air compressor operation.

Changing the Fluorescent Tube

Ensure the transformer is disconnected from the power 
supply before opening the lid and cutting the two ties 
securing the lamp to its retaining clips.

Carefully pull the lamp from its retaining clips then hold 
the clear plastic protective outer tube firmly and ease 
off the plastic end cover from the non-wired end. (This 
may take a little persuasion and perseverance). Once 
the end cover has been removed, hold the end cover 
at the opposite end (the cable input end), and pull off 
the outer protective clear plastic tube.

The fluorescent tube is now fully revealed. Pull off the 
end connector, which secures a wire to one of the 
pins, taking care not to distort the aluminium reflector. 
Then pull off the wire secured by a plastic sheath to 
one of the pins at the cable input end. 

Assemble in reverse order, ensuring the wires are cor-
rectly held by the plastic sheath at one end and the 
end connector at the other, with the reflector correctly 
in position.

Replace the assembly into its retaining clips and test its 
operation by plugging the transformer in to the mains.

Summary of Contents for 24815

Page 1: ...esult in personal injury and or damage to product or property Please retain instructions for future reference Unpacking After unpacking unit inspect carefully for any damage that may have occurred dur...

Page 2: ...be used with a vacuum extraction device Air is extracted via a double filtration system from the facility at the right hand side of the cabinet Please note that when vacuum extraction is used air wil...

Page 3: ...the 16mm dia hole in the cabinet from the inside as shown in Fig 2 Ensure a flat washer is threaded on to the adapter as shown Thread a flat washer followed by the extended nut on to the adapter from...

Page 4: ...into the power supply and switch the power ON Switch the lamp ON by pushing the rocker switch on the switch box I Switch OFF by pushing O Ensure all air connections are secure and the pick up is corr...

Page 5: ...e opening the lid and cutting the two ties securing the lamp to its retaining clips Carefully pull the lamp from its retaining clips then hold the clear plastic protective outer tube firmly and ease o...

Page 6: ...6 Operating Instructions and Parts Manual 24815 SANDBLAST BENCH TOP CABINET 5 19 2019 OEMTOOLS PARTS LIST AND DIAGRAM 36 24 25 26...

Page 7: ...ng disc 24815 10 30 Abrasive Intake Hose 24815 30 11 Rubber Gloves pair 24815 11 31 Air Hose Adapter 24815 31 12 Worm Drive Clip 24815 12 32 Worm Drive Clip 24815 32 13 Clear Plastic Lid 24815 13 33 A...

Page 8: ...asive or dry thoroughly before use Check air line to ensure it is free from moisture Inadequate speed or inefficient blast Abrasive media worn Pressure too low Replace abrasive media Increase inlet pr...

Reviews: