5
Operating Instructions and Parts Manual
24815
SANDBLAST BENCH TOP CABINET
5/19
2019 OEMTOOLS
™
MAINTENANCE
Before use, check to ensure that all parts are service-
able, including the air inlet hose, rubber gloves and
abrasive pick-up.
Ensure the air vent foam filter is in place.
The swivel clamps, securing the lid, must be secure so
as not to allow the lid to open during operation. The
build up of air pressure within the cabinet could force
the lid open, allowing abrasive to escape. This is not
only wasteful, but could be a health hazard.
Ensure the filters are serviceable and seated correctly.
Ensure you comply with all precautions regarding the
use of compressed air, and air compressor operation.
Changing the Fluorescent Tube
Ensure the transformer is disconnected from the power
supply before opening the lid and cutting the two ties
securing the lamp to its retaining clips.
Carefully pull the lamp from its retaining clips then hold
the clear plastic protective outer tube firmly and ease
off the plastic end cover from the non-wired end. (This
may take a little persuasion and perseverance). Once
the end cover has been removed, hold the end cover
at the opposite end (the cable input end), and pull off
the outer protective clear plastic tube.
The fluorescent tube is now fully revealed. Pull off the
end connector, which secures a wire to one of the
pins, taking care not to distort the aluminium reflector.
Then pull off the wire secured by a plastic sheath to
one of the pins at the cable input end.
Assemble in reverse order, ensuring the wires are cor-
rectly held by the plastic sheath at one end and the
end connector at the other, with the reflector correctly
in position.
Replace the assembly into its retaining clips and test its
operation by plugging the transformer in to the mains.