OEM HVPS-300 User Manual Download Page 11

 

Bench-top version 

 

 
Bench-top version with 100-240VAC input is also available. 

 

 

Summary of Contents for HVPS-300

Page 1: ...020 09 18 HVPS 300 high voltage power supply with bipolar output User manual Warning This equipment produces high voltages that can be very dangerous Please read user manual carefully before starting...

Page 2: ...2kV at HV negative pin Due to bipolar output and high stability of HV output see Specifications section the target application of HVPS 300 is feeding high voltage high repetition rate Pockels cell dri...

Page 3: ...supplied to these pins to power up the HVPS 300 Current consumption is up to 20A at full output power black GND 24VDC return Warning Because of safety reasons we highly recommend to use low voltage p...

Page 4: ...ponds to VMAX at the output 5 black GND Interface return Return of all Interface signals Enable HV Monitor Fault except HV Program 6 N C 7 orange HV Program Return Return of HV Program signal In order...

Page 5: ...jumper along with HV Program trimming potentiometer should be used instead of HV Program signal Enable jumper is set between pins 1 and 2 HV program jumper is set between pins 9 and 10 HV OUTPUT DSUB...

Page 6: ...ply to be mounted with 4pcs M4 screws M4x10 or shorter Grounding policy By default all grounds of HVPS 300 HV Output Ground 24VDC RETURN and Interface Returns are interconnected inside the power suppl...

Page 7: ...n Do not operate with disconnected load Avoid casual contacts of personnel with output cables and with the load Do not turn the power supply on if it was already damaged with water chemicals mechanica...

Page 8: ...other HV negative see also figure below By default all descriptions of HV outputs are given in terms of voltage differences Please keep this in mind Output power depends on the operating voltage Rate...

Page 9: ...0 40 C Storage temperature 20 60 C Humidity 90 non condensing 1 In terms of bipolar output see also Technical notes section MECHANICAL SPECIFICATION Size LxWxH 169x107x59mm without inputs and outputs...

Page 10: ...Dimensions 454 00 00 000 06 1 454 00 00 000 06 454 00 00 000 06 1 1 0 42 A2 HVPS300 OEM Tech A A A A 172 4 169 155 182 9 63 7 59 106 5 109 8 A A A A 70 135 9 M4 7H 4 18 25...

Page 11: ...Bench top version Bench top version with 100 240VAC input is also available...

Reviews: