Odorox IDU Owner'S Manual Download Page 8

T

h

e P

Y

U

R

E C

o

m

p

an

y

3 1

4 1

1 1

6 4

7 4

8 6

2 1

9 1

9 1

5 4

2X 

3.750

2X 

7.500

3.50

7.00

13.750

8X 

.250

4.313

8.625

6.00

12.00

6.875

EXISTING DUCT (METAL OR FIBERGLASS)

1.

POWER REQUIREMENT: 120V, 60HZ @ 0.8AMPS.

2.

2 PYURE 

OPTICS: PART #HG9187-LV33.

NOTES:

CUTOUT DETAIL FOR DUCT: SCALE 1=4

ITEM  NO.

QTY

UOM

PART NUMBER

NOTE

DESCRIPTION

11

EA

IDU02MA02A

UV BOX ASSEMBLY

21

EA

IDU02MA010

CONTROL BOX ASSEMBLY

31

EA

IDU02MD13A

DUCT REINFORCEMENT PLATE, OUTSIDE

41

EA

IDU02MD14A

DUCT REINFORCEMENT PLATE, INSIDE

54

EA

SCR-S8-131

SCREW, PAN HEAD PHILLIPS, M/S, #8-32 X 5/8 IN LG, 18-8 SST

64

EA

WSH-S8-141

WASHER, #8, HI COLLAR L/W, 18-8 SST

74

EA

NUT-S8-116

NUT, HEX, SST, 8-32 THD

86

EA

NUT-S8-306

NUT, ACORN, #8-32 THD, BLACK LUSTER-COATED STEEL

9

108

IN

GSK-XX-311

GASKET, RUBBER & FOAM, ADHESIVE, 3/16" THK, 1/2" W, GRAY

D

C

B

A

A

B

C

D

1

2

3

4

5

6

7

8

8

7

6

5

4

3

2

1

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF HGI  INDUSTRIES.   ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF HGI  INDUSTRIES IS PROHIBITED.

PROPRIETARY AND CONFIDENTIAL

DRAWN

CHECKED

ENG APPR.

MFG APPR.

DATE

NAME

The PYURE Company

SIZE

B

DWG.  NO.

REV

UNLESS OTHERWISE SPECIFIED:

0

GREEN TECHNOLOGY AT WORK

PROJECT NAME

Q.A.

DIMENSIONS ARE IN INCHES AND TOLERANCES: FRACTIONAL  

1/16

ANGULAR: MACH 

.25  BEND 

1

TWO PLACE DECIMAL  

.020

THREE PLACE DECIMAL  

.010

INTERPRET GEOMETRIC TOLERANCING PER:   ANSI 14.1Y DO NOT SCALE DRAWING

TOP ASSEMBLY

IDU02MA00

WEIGHT: 

SCALE:  1=4

SHEET    1    OF     1

JDU

6/14/2010

INDUCT DU

6

Owner’s Manual

INSTALLATION INSTRUCTIONS

Summary of Contents for IDU

Page 1: ...Odorox IDU Induct Unit Distributed By Bio Shine dba OdoroxAir Owners Manual 190 Summerhill Road Spotswood NJ 08884 732 25 251 9506 ext 211 odoroxair bio shine com www OdoroxAir com...

Page 2: ...TS 4 INSTALLATION INSTRUCTIONS 5 OPERATING GUIDELINES 10 CARE INSTRUCTIONS 11 OPTIC REPLACEMENT INSTRUCTIONS 12 TROUBLESHOOTING GUIDE 13 SPECIFICATIONS REPLACEMENT PARTS AND LIMITED WARRANTY 14 LIMITE...

Page 3: ...ce or cleaning Use generator only for intended use as described in this manual INDOOR USE ONLY Caution For General Ventilating Use Only Do Not Use to Exhaust Hazardous or Explosive Materials and Vapor...

Page 4: ...cleaner mop or broom Dispose of clothing fabric etc that has come in contact with mercury do not wash Only the individual to clean up the spill should re occupy the space Close the doors to the area...

Page 5: ...ll the items that were used to pick up the mercury including index cards or cardboard eyedropper contaminated tape paper towels and zipper type bags into the trash bag Carefully remove rubber gloves b...

Page 6: ...Odorox IDU Hydroxyl Generator Unit 2 One IDU02MD13A Duct Reinforcement Plate Outside 3 One IDU02MD14A Duct Reinforcement Plate Inside 4 One 108 GSK XX 311 Gasket Rubber Foam Adhesive 3 16 THK 1 2 W Gr...

Page 7: ...duct location Odorox IDUTM Installation STEP 1 Remove the IDU unit from its packaging STEP 2 Remove the optics from the packaging material The optics are fragile use extreme care Do not touch the gla...

Page 8: ...8 6 EA NUT S8 306 NUT ACORN 8 32 THD BLACK LUSTER COATED STEEL 9 108 IN GSK XX 311 GASKET RUBBER FOAM ADHESIVE 3 16 THK 1 2 W GRAY D C B A A B C D 1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 1 THE INFORMATION CONT...

Page 9: ...Odorox IDUTM 7 INSTALLATION INSTRUCTIONS...

Page 10: ...TEP 7 Secure duct reinforcement plates by installing four 8 32 nuts and lock washers provided STEP 8 Install the IDU unit by routing the aluminum chamber through the opening and securing to the plate...

Page 11: ...urrent sensing relay or pressure switch may be necessary Check with the equipment manufacturer Neutral Line 1 Line 1 Line 2 Dedicated 120 Volt 60 Cycle 15 Amp Circuit Mini HVAC Blower Control 208 Volt...

Page 12: ...l assuming 2 air changes per hour ACH 85 recirculated air and 9 foot 2 7 m ceilings The guidelines should be adhered to in order to ensure optimal performance and safety Note if the air changes per ho...

Page 13: ...of the Odorox product can be cleaned in the same manner as the exterior OPTIC CLEANING Cleaning of the optics is recommended to maintain peak processing efficiency Fingerprints smudges dirt dust parti...

Page 14: ...porcelain end of the optic use your other hand to grip the optic connector Gently wiggle connector while pulling from the optic base Gently pull the optic from the three optic support clips Do not put...

Page 15: ...ptic has failed Contact local distributor for service Blue LED has failed Contact local distributor for service Internal component failure Contact local distributor for service Optic not functioning R...

Page 16: ...peration and maintenance of your Odorox product please contact your local Odorox distributor To find a distributor in your area please visit www pyureco com contact or www odorox com contact The PYURE...

Page 17: ...Road Boynton Beach FL 33426 The PYURE Company 2055 High Ridge Road Boynton Beach FL 33426 Complete below and reverse side Tear along perforation and mail to The PYURE Company within 60 days of purcha...

Page 18: ...warranty whichever is longer This warranty card does not apply in the following cases a damage to product due to mishandling alteration failure to follow operation maintenance or environmental instruc...

Page 19: ...e copyrights and other intellectual property rights in the Licensed PYURE Software and any copies thereof You may use a copy of the Licensed PYURE Software with any Odorox product for which you have a...

Page 20: ...SE PRICE IN NO EVENT SHALL THE PYURE COMPANY S ENTIRE LIABILITY UNDER THIS EULA EXCEED THE PURCHASE PRICE EVEN IF THE LICENSED PYURE SOFTWARE PRODUCT IS DOWNLOADED WITH OTHER THIRD PARTY SOFTWARE FREE...

Page 21: ...ight 2020 The PYURE Company ODOROX and IDUTM Powered by PYURE TechnologyTM are trademarks of The PYURE Company Boynton Beach FL 33426 USA 190 Summerhill Road Spotswood NJ 08884 732 25 251 9506 ext 211...

Reviews: