SAFETY INFORMATION

Safe Handling and Disposing of Mercury

Mercury is used in the IDU™ device in order to generate the plasma needed to produce UV-C radiation. This 
is similar to the use of mercury in many types of commercial, fluorescent light fixtures. As long as the glass or 
quartz outer bulb is intact, mercury is contained within the fixture and poses no health hazard. In the event 
that an optic breaks, less than 25 mg of mercury could be released. This is much less than what is present in a 
commercial thermometer. Liquid metallic mercury is hazardous due to its potential to release mercury vapor. In 
humans, approximately 80% of inhaled mercury vapor is absorbed via the respiratory tract, where it enters the 
circulatory system and is distributed throughout the body. Short term exposure to 25 mg of spilled mercury does 
not pose a health hazard, 

provided that the source of the mercury is removed promptly

. Chronic exposure by 

inhalation, even at low concentrations in the range 0.7–42 μg/m3, can cause effects such as tremors, impaired 
cognitive skills, and sleep disturbance in workers. The OHSA limit for occupational exposure of elemental 
mercury is 0.1 mg/m3. Mercury is also used in most fluorescent light fixtures.

In the event that the device optic light does not function, the optics should be checked to ensure that they are 
intact. If the optic is cracked, but not broken, it should be replaced. Cracked optics should be double sealed in 
plastic bags and disposed of according to local, approved procedures. In the event that the optic breaks and the 
mercury spilled is clean-up should be done immediately according to the following procedure published by the 
Environment Protection Agency.

• Evacuate the room for at least 15 minutes
• Do not attempt to clean up the spill with a vacuum 

cleaner, mop or broom.

• Dispose of clothing, fabric etc. that has come in

contact with mercury; do not wash.

• Only the individual to clean up the spill should re-

occupy the space.

• Close the doors to the area of the spill and turn

off the HVAC system; open exterior windows and
direct room air out of the window with fans or use
an exhaust fan if the area is equipped with one that
vents directly outdoors.

• Cover shoes with disposable foot covers or wear

shoes that will be disposed of.

• Remove jewelry as mercury will amalgamate with

metals and ruin them .

• Use a commercial mercury spill clean-up kit to

remove the spilled mercury. (See list of suppliers

on the next page).

Identify items in the spill area that can be
cleaned and those that cannot.

 Non-porous

surfaces (finished wood, plastic or concrete)
can be cleaned following this guidance. Porous
surfaces or fabric-covered items (upholstery,

carpeting, stuffed animals, pillows, backpacks, 

unfinished wood, cork, cardboard) are difficult to 

clean because mercury beads may be trapped in 
these materials. If you decide you cannot clean 
these items, place them in plastic trash bags or 
cover or wrap them in a double layer of plastic and 
carefully seal with tape. Place the wrapped items in 
a secure place, preferably outdoors and out of the 

reach of children and pets. You should consult with 
a trained professional about how to decontaminate 

or dispose of these items safely.

Wear gloves to carefully pick up the larger pieces
of broken glass and what remains of the broken
device and place them on a paper towel. 

Gently

fold the paper towel around these pieces so you
can pick the bundle up and place it in a zipper-type
plastic bag. 

Use index cards or stiff cardboard to

push smaller pieces of glass and mercury beads
together into a pile. 

Shine a flashlight at an angle

to locate beads of mercury. The beads will reflect
light from the flashlight. Check for mercury in
cracks or in hard-to-reach areas where beads may
be hidden or trapped. Check a wide area beyond
the spill.

Summary of Contents for IDU

Page 1: ...Odorox IDU Induct Unit Distributed By Bio Shine dba OdoroxAir Owners Manual 190 Summerhill Road Spotswood NJ 08884 732 25 251 9506 ext 211 odoroxair bio shine com www OdoroxAir com...

Page 2: ...TS 4 INSTALLATION INSTRUCTIONS 5 OPERATING GUIDELINES 10 CARE INSTRUCTIONS 11 OPTIC REPLACEMENT INSTRUCTIONS 12 TROUBLESHOOTING GUIDE 13 SPECIFICATIONS REPLACEMENT PARTS AND LIMITED WARRANTY 14 LIMITE...

Page 3: ...ce or cleaning Use generator only for intended use as described in this manual INDOOR USE ONLY Caution For General Ventilating Use Only Do Not Use to Exhaust Hazardous or Explosive Materials and Vapor...

Page 4: ...cleaner mop or broom Dispose of clothing fabric etc that has come in contact with mercury do not wash Only the individual to clean up the spill should re occupy the space Close the doors to the area...

Page 5: ...ll the items that were used to pick up the mercury including index cards or cardboard eyedropper contaminated tape paper towels and zipper type bags into the trash bag Carefully remove rubber gloves b...

Page 6: ...Odorox IDU Hydroxyl Generator Unit 2 One IDU02MD13A Duct Reinforcement Plate Outside 3 One IDU02MD14A Duct Reinforcement Plate Inside 4 One 108 GSK XX 311 Gasket Rubber Foam Adhesive 3 16 THK 1 2 W Gr...

Page 7: ...duct location Odorox IDUTM Installation STEP 1 Remove the IDU unit from its packaging STEP 2 Remove the optics from the packaging material The optics are fragile use extreme care Do not touch the gla...

Page 8: ...8 6 EA NUT S8 306 NUT ACORN 8 32 THD BLACK LUSTER COATED STEEL 9 108 IN GSK XX 311 GASKET RUBBER FOAM ADHESIVE 3 16 THK 1 2 W GRAY D C B A A B C D 1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 1 THE INFORMATION CONT...

Page 9: ...Odorox IDUTM 7 INSTALLATION INSTRUCTIONS...

Page 10: ...TEP 7 Secure duct reinforcement plates by installing four 8 32 nuts and lock washers provided STEP 8 Install the IDU unit by routing the aluminum chamber through the opening and securing to the plate...

Page 11: ...urrent sensing relay or pressure switch may be necessary Check with the equipment manufacturer Neutral Line 1 Line 1 Line 2 Dedicated 120 Volt 60 Cycle 15 Amp Circuit Mini HVAC Blower Control 208 Volt...

Page 12: ...l assuming 2 air changes per hour ACH 85 recirculated air and 9 foot 2 7 m ceilings The guidelines should be adhered to in order to ensure optimal performance and safety Note if the air changes per ho...

Page 13: ...of the Odorox product can be cleaned in the same manner as the exterior OPTIC CLEANING Cleaning of the optics is recommended to maintain peak processing efficiency Fingerprints smudges dirt dust parti...

Page 14: ...porcelain end of the optic use your other hand to grip the optic connector Gently wiggle connector while pulling from the optic base Gently pull the optic from the three optic support clips Do not put...

Page 15: ...ptic has failed Contact local distributor for service Blue LED has failed Contact local distributor for service Internal component failure Contact local distributor for service Optic not functioning R...

Page 16: ...peration and maintenance of your Odorox product please contact your local Odorox distributor To find a distributor in your area please visit www pyureco com contact or www odorox com contact The PYURE...

Page 17: ...Road Boynton Beach FL 33426 The PYURE Company 2055 High Ridge Road Boynton Beach FL 33426 Complete below and reverse side Tear along perforation and mail to The PYURE Company within 60 days of purcha...

Page 18: ...warranty whichever is longer This warranty card does not apply in the following cases a damage to product due to mishandling alteration failure to follow operation maintenance or environmental instruc...

Page 19: ...e copyrights and other intellectual property rights in the Licensed PYURE Software and any copies thereof You may use a copy of the Licensed PYURE Software with any Odorox product for which you have a...

Page 20: ...SE PRICE IN NO EVENT SHALL THE PYURE COMPANY S ENTIRE LIABILITY UNDER THIS EULA EXCEED THE PURCHASE PRICE EVEN IF THE LICENSED PYURE SOFTWARE PRODUCT IS DOWNLOADED WITH OTHER THIRD PARTY SOFTWARE FREE...

Page 21: ...ight 2020 The PYURE Company ODOROX and IDUTM Powered by PYURE TechnologyTM are trademarks of The PYURE Company Boynton Beach FL 33426 USA 190 Summerhill Road Spotswood NJ 08884 732 25 251 9506 ext 211...

Reviews: