OctiveTech 300AH Operating Instructions Manual Download Page 2

▒▓

 

www.OctiveTech.com

 Operating 

Instructions 

3

 

CHAPTER 1 INTRODUCTION   

1.1 Brief Introduction 

Thank you for using the handheld pulse oximeter. The main functions of this device 
are to measure SPO2 and PR, visual and audio alarm, sensor off alarm, data storage 
and replay etc. Please read the operator’s manual carefully before operating it. 

Application range

: The device is used to monitor patient’s arterial oxygen saturation 

and pulse rate continuously.

 

 

1.2 Safety Information 

                                                                                               

 

 

 

 The  handheld pulse oximeter is to be operated by qualified personnel only.   

Before using, carefully read this manual, directions for using of accessory, all 
precautions, and all specifications. The user must check that the equipment 
functions safely and ensure that it is in proper working condition before being 
used. 

 The  is intended for use only as an adjunct in patient assessment. It must be 

used in conjunction with clinical signs and symptoms. 

  To avoid an electrical hazard, never immerse the unit in any fluid or attempt to 

clean it with liquid cleaning  agents. Always take out the batteries before 
cleaning. 

  If oximeter becomes accidentally wet during use, stop operation of the oximeter 

until all affected   

      components have been cleaned and permitted to dry completely. Contact your 

local representative if additional information is required.       

 If any parameters displayed on oximeter is not accurate, adopt the other 

methods to diagnosis patient. 

 The medical equipment must be manipulated by personnel who have already 

gotten the relative training of operation. 

  For safe and accurate operation, use only recommended accessories. Request 

for the special children or     infant accessories, when monitoring infant or 

▒▓

 

www.OctiveTech.com

 Operating 

Instructions 

4

 

children. 

  Do not use the oximeter in the presence of a flammable anesthetic mixture with 

air, oxygen or nitrous     oxide 

  Alarm must be set up according to different situation of individual patient. Make 

sure that audio sound can be activated when alarm occurs

● 

For proper equipment maintenance, perform the service procedures at the 

recommended intervals as described in the manual. 

Do not use the oximeter during Magnetic Resonance Imaging (MRI) scanning. 
Induced current could   potentially cause burns. The oximeter may affect the 
MRI image, and the MRI unit may affect the accuracy of oximeter measurements. 

● 

The oximeter can monitor only one patient synchronously. 

  As to the other points for attention, please carefully read the relevant chapter in 

this instruction.

 

1.3 Electromagnetism interference 

The oximeter is low power consumption device. It will not interference 
surrounding people, device and environment. Nevertheless, if there is strong 
electromagnetic interference near the equipment, it may result in harmful 
interference, even makes performance inactivate. Therefore, if any the warp of 
anticipated effect appears, you should firstly prevent, identify and solve the 
adverse electromagnetic interference, then proceed to use the device. 
To reduce possible problems caused by electromagnetic interference, we 
recommend the following: 
1.  Interference from adjacent radio or mobile phone. 
If the radio is the interference source, install the equipment in other place. If the 
mobile phone is the source, make it far away from the equipment.   
2.  Direct and indirect electrostatic discharge:   
Before using equipment, make sure operator and patient who touch the 
equipment have no direct or indirect electrostatic power. Damp room is helpful to 
remit such problem.

   

 

1.4 Conception of Warning, Caution and Note 

Warning, Caution and Note 
The Warning, Caution and Note in the manual are special information to draw the 
operator’s attention. 
 

 Warning

 

Summary of Contents for 300AH

Page 1: ...1 3 Electromagnetism interference 4 1 4 Conception of Warning Caution and Note 4 CHAPTER 2 OVERVIEW of SYSTEM 6 2 1 Summary 6 2 2 Specifications 6 CHAPTER 3 OPERATION GUIDE 7 3 1 Appearance 7 3 2 Disp...

Page 2: ...children Do not use the oximeter in the presence of a flammable anesthetic mixture with air oxygen or nitrous oxide Alarm must be set up according to different situation of individual patient Make su...

Page 3: ...eform SPO2 pulse column Data SPO2 PR Others Connection status of probe time and remaining battery energy Alarm Alarm SPO2 probe off Alarm mode audio alarm visual alarm flash the value and information...

Page 4: ...lay automatically If you want to power off the oximeter press the ON OFF button for several seconds 3 3 2 Function buttons Right button Enter main menu from normal display and change the setting value...

Page 5: ...eturn the main menu Attention There are three selections for the Alarm Type The first is Visual Alarm when you select this item only visual alarm is responded when alarm event happens the audio alarm...

Page 6: ...10 to display the SPO2 trend graph shown as Fig3 12 Fig 3 12 The ordinate shown as Fig 3 12 represents the value of SPO2 the abscissa represents the time 60 points can be displayed synchronously in o...

Page 7: ...nd 19 Minute 17 Hour Date Set 15 Day 12 Month 2004 Year www OctiveTech com Operating Instructions 14 Fig 3 16 Press or to highlight the item you want to set then press or to adjust the item you select...

Page 8: ...nitor 4 2 1 Chief introduction What is SpO2 Monitoring SpO2 plethysmogram measurement is employed to determine the oxygen saturation of hemoglobin in the arterial blood that is the percentage of hemog...

Page 9: ...emoglobin methylene blue Indigo carmine 4 2 3 3 Extreme illumination would affect the Spo2 measurement using nontransparent cover to shield the sensor would get the better performance Note Pulse senso...

Page 10: ...stipulations and lead to oximeter failure and possible health damage our company has right to change the warranty period a Should make the effective maintenance plan for oximeter and reused parts Thi...

Page 11: ...nce www OctiveTech com Operating Instructions 22 d Responsibility limitation During the period of warranty if user changes the parts manufactured by the third party without our company permission our...

Page 12: ...er offer oximeter Storage and Transportation Storage Storage Temperature 10 C 40 C Relative Humidity 90 Transportation Transport by air train or vessel after packing according to request Packing list...