![background image](http://html1.mh-extra.com/html/octane-fitness/lx-8000-touch/lx-8000-touch_preventative-maintenance-and-diagnostics_723704009.webp)
9
SUPPORT.OCTANEFITNESS.COM
SERVICE TRAINING
Diagnostics
The
Manual Tests
section provides tools for you to use
in testing various functions of the console.
Heart Rate:
Grasp the contact heart rate grips; you
should see a value displayed in the Heart
Rate field. You may also test the wireless
heart rate function by wearing a heart rate
strap.
Speed:
Pedal the machine to verify RPMs.
Direction:
Pedal the machine forward and in reverse to verify direction is sensed correctly.
Stride:
Press
the
–
and
+
buttons on the screen to verify stride motor adjustment in both directions.
Level:
Press
the
–
and
+
buttons on the screen to verify level adjustments in both directions.
Fingertip Controls:
Stride
Press
the
–
and
+
adjustment buttons on the
LEFT
moving handlebar. The touch screen buttons
turn green when the buttons are working properly.
Level
Press
the
–
and
+
adjustment buttons on the
RIGHT
moving handlebar. The touch screen buttons
turn green when the buttons are working properly.
The
Auto Tests
section helps you find potential issues
in the brake, accessory tray LCD, ANT+ Interface,
FitLinxx interface and stride motors.
Press the touch screen button in the top portion of this
section to select a test, then press
Start Test
. Once you
have gathered the information you need, press
Stop Test
.
The lower portion of this section is for testing the stride
motors. Press
Start Test
and review the information as
it is displayed. Once you have gathered the information
you need, press
Stop Test
.
If errors are detected during any these tests, note the
information and contact Octane Fitness for assistance.
Press
Exit
to leave this view and return to the main screen.
The RESET PAC button does not function from this screen. If you
believe you need to reset the Power and Control Board, contact
Octane Fitness for assistance.