background image

 

Document UT-MT-0728 

Page 6 of 14

 

 

Edition 13/11/2018 

 

 

LED STANAG LUMINOUS DISTANCE SIGNS LSDS 
INSTRUCTION MANUAL FOR USE, INSTALLATION AND MAINTENANCE 

 

 
The power required to CCR per each sings is: 
 

CCR Total Load 

2.8 A-6.6 A

 

4.8 A-6.6 A 

6.6 A 

190 VA 

110 VA 

80 VA 

Table 5 – CCR Total Load 

3.3

 

Luminance Data 

The luminance of the sign faces is practically constant for any value of the series circuit current 
from 2.8 A through 6.6 A. 
 

COLORS AT 6.6 A (cd/m

2

YELLOW 

WHITE 

190 

350 

TabLe 6 – Luminance Data 

NOTE:  the  electrical  and  luminous  data  are  referred  to  constant  current  regulators  and 
isolating  transformers  manufactured  and/or  distributed  by  OCEM.  The  data  may  change 
with constant current regulators and/or transformers manufactured by other Companies. 

3.4

 

Description of the Signs 

The signs practically include the following sections: 
 
a)

 

main structure 

b)

 

panels for faces 

c)

 

LEDs luminous source 

d)

 

electronic boards. 

3.4.1

 

Main Structure 

The  main  structure  principally  consists  of  a bearing  bottom  structure,  two  sides,  one  top  cover 
and assembling-supporting components. 
Bottom  structure,  sides  and  top  cover  are  made  of  extruded  aluminium  profiles,  realized 
according to our design. 
Each  module  is  supported  by  four  mountings,  each  including  a  leg,  a  breakable  coupling  and  a 
floor flange. All these components are cast aluminium. 
The  signs  are  equipped with  a  single  top  cover, locked  to  the  main  structure  by  means  of  four 
hexagonal knob. The main structure is matt black outside painted. 

Summary of Contents for LSDS

Page 1: ...SINCE IT IS FILED AND DELIVERED BY MEANS OF THE AUTOMATIC KNOWLEDGE MANAGEMENT SYSTEM IT CAN BE SIGNED ON REQUEST THIS DOCUMENT AND THE DATA CONTAINED HERE IN IS PROPRIETARY PROPERTY AND SHALL NOT BE...

Page 2: ...18 LED STANAG LUMINOUS DISTANCE SIGNS LSDS INSTRUCTION MANUAL FOR USE INSTALLATION AND MAINTENANCE EDITIONS Date 09 09 2013 First Issue REVISIONS Index Date Description Edited by Approved by 01 13 11...

Page 3: ...3 4 2 Panel for Faces 7 3 4 3 LEDs Luminous Source 7 3 4 4 Electronic Board 8 4 INSTALLATION 10 5 MAINTENANCE 13 5 1 Periodical Checks 13 5 2 LEDs Luminous Source Replacement 13 5 3 Electronic Equipme...

Page 4: ...factured to be used on airport series circuits through isolating transformers powered by 5 step 2 8A 6 6A 3 step 4 8A 6 6A 1 step 6 6A Constant Current Regulators Consult STANAG Specs 3316 and or nati...

Page 5: ...2 Tether 2 70 Bird Spikes 3 MAIN FEATURES 3 1 Environmental Data Temperature From 40 C to 55 C Weather All outdoor conditions exposure to driving rains snow and icing salt laden atmospheres relative h...

Page 6: ...OCEM The data may change with constant current regulators and or transformers manufactured by other Companies 3 4 Description of the Signs The signs practically include the following sections a main s...

Page 7: ...mensions 3 4 2 Panel for Faces The panels for faces are made of high performance methacrylate 5 mm thick The legend is obtained by means of adhesive coloured translucent films applied to the internal...

Page 8: ...By varying the current of the CCR in the range 2 8 6 6 A the power supply board provides a constant current to each luminous source This allows a constant luminance regardless the step of the CCR For...

Page 9: ...Document UT MT 0728 Page 9 of 14 Edition 13 11 2018 LED STANAG LUMINOUS DISTANCE SIGNS LSDS INSTRUCTION MANUAL FOR USE INSTALLATION AND MAINTENANCE Figure 2 Wiring diagram...

Page 10: ...langes is very important to ease the installation of the sign Place a long carpenter level across the top of the breakable couplings to verify their alignment and levelling Do not tighten the flanges...

Page 11: ...Document UT MT 0728 Page 11 of 14 Edition 13 11 2018 LED STANAG LUMINOUS DISTANCE SIGNS LSDS INSTRUCTION MANUAL FOR USE INSTALLATION AND MAINTENANCE Figure 3 Flange installation with anchor bolts...

Page 12: ...UT MT 0728 Page 12 of 14 Edition 13 11 2018 LED STANAG LUMINOUS DISTANCE SIGNS LSDS INSTRUCTION MANUAL FOR USE INSTALLATION AND MAINTENANCE 600 500 250 570 250 2200 3500 251 800 Figure 4 Concrete fou...

Page 13: ...s of the damaged LEDs luminous source and loosen the four nuts at the angles of the support then slide and lift the support to extract it from its seat d Unscrew the six screws of the damaged LEDs lum...

Page 14: ...ce s Replace the LED s luminous source s Defective isolating transformer Replace isolating transformer Defective power supply board Replace power supply board The main switch is left to OFF position T...