3.2
Electrical Data
3.2.1
Current Power Supply
The luminous signs are powered by series circuits through isolating transformers, meeting FAA
Specs FAA L830-L831, in the following ratings (see table 4)
SIZE TRANSFORMERS case SCR
TRANSFORMER RATING [W] to the
currents of:
Sign modules
1
2
3
4
6,6A
65
150
200
300
4,8 - 6,6A
100
150
300
300
2,8A - 6,6A
STANDARD
150
300
400
500
Opt.18
//
//
//
2x300
SIZE TRANSFORMERS case Sinusoidal
TRANSFORMER RATING [W] to the
currents of:
Sign modules
1
2
3
4
6,6A
65
100
150
200
4,8 - 6,6A
65
150
200
300
2,8A - 6,6A
STANDARD
100
200
300
400
Opt.18
//
//
//
2x200
Table 4 – Series Insulating Tranformer size
The power required to CCR per each sings is:
Sign
Modules
CCR Total Load
2.8 A-6.6 A
5 STEP
4.8 A-6.6 A
3 STEP
6.6 A
1 STEP
1
92 VA
53 VA
39 VA
2
176 VA
103 VA
75 VA
3
260 VA
152 VA
110 VA
4
344 VA
201 VA
146 VA
Table 5 - CCR Total Load