Document UT-MT-0699
Page 6 di 27
Edition 12/02/2019
Supersedes edition
26/07/2016
LED LUMINOUS GUIDANCE SIGN LIGS01
INSTRUCTION MANUAL FOR USE, INSTALLATION AND MAINTENANCE
2.3
Part Number Identification
LIGS 01 – 32 – 1 – XX
Basic Part Number:
Version:
Size:
3 = Sign, 300 mm Legend Height
4 = Sign, 400 mm Legend Height
Number of Faces:
1 = Single Face
2 = Double Face
Number of Modules*:
1 to 4
Options:
01 = Tether
10 = Monitoring
18 = Double power supply for 3 and 4 module signs
48 = Reinforced version FAA-mode 3 (483 km/h)
55 = Protection degree IP55
69 = Orange rear side for single face signs (ENAC only)
70 = Bird Spikes
71 = ON-OFF Key switch
D2 = Supply voltage (an external 230/37 Vac transformer is required).
*
One module corresponds to 1 meter. 4 modul signs are not confoming to the reccomandations
of ICAO Aerodrome Design Manual - Part 6 (maximun length of the signs 3m).
3
MAIN FEATURES
3.1
Environmental Data
Temperature
-40°C to +55°C
Weather
All outdoor conditions, exposure to: driving rains, snow and icing, salt-
laden atmospheres, relative humidity from 5 % to 95 %.
Wind Speed
322 km/h ICAO Aerodrome Design Manual Part 6 Frangibility
Radio Interference
None
Table 3 - Environmental Data