Oceanic OCS Operating Manual Download Page 59

59

OCS OPERATING MANUAL

© 2002 Design, 2011

Doc. No. 12-5272-r01 (9/28/11)

CAN BE USED AS

•  Watch

•  Dive Computer (Air or Nitrox) 

•  Digital Depth Gauge/Timer

•  Free Dive activity

•  Compass

DIVE COMPUTER PERFORMANCE

•  Buhlmann ZHL-16c based PZ+, or DSAT based, algorithm

•  No Deco limits closely follow PADI RDP

•  Decompression in agreement with Buhlmann ZHL-16c and French MN90

•  No Deco Deep Stops - Morroni, Bennett

•  Deco Deep Stops (not recommended) - Blatteau, Gerth, Gutvik

•  Altitude - Buhlmann, IANTD, RDP (Cross)

•  Altitude corrections and O2 limits based on NOAA tables 

OPERATIONAL PERFORMANCE

Function:

 

Accuracy:

•  Depth  

±1% of full scale

•  Timers 

1 second per day

Dive Mode Activation:

•   Must be in Dive Computer mode, if Wet Activation is set OFF.

•   Automatic by immersion in water, if Wet Activation is set ON.

•   Cannot be manually activated deeper than 5 FT (1.5 M), if Water Activation is set OFF.

•   Cannot operate as a DC at elevations higher than 14,000 feet (4,270 meters) 

Dive Counter:

•  NORM/GAUG displays Dives #1 to 24, FREE displays #1 to 99 (0 if no dive made yet) 

•  Resets to Dive #1, upon diving (after 24 hours with no dives)

Dive Log Mode:

•  Stores 24 most recent NORM/GAUG dives in memory for viewing

•  After 24 dives, adds 25th dive in memory and deletes the older dive

Altitude:

•  Operational from sea level to 14,000 feet (4,270 meters) elevation

•  Measures ambient pressure every 30 minutes in Watch Mode, when Dive Computer Mode is accessed, and every 15 minutes while in NORM/GAUG/FREE Surface Modes.

•  Does not measure ambient pressure when Wet.

•  Compensates for Altitudes above sea level beginning at 3,001 feet (916 meters) elevation and every 1,000 feet (305 meters) higher.

Power:

•  Battery 

(1) 3 vdc, CR2450, Lithium battery (Panasonic or equivalent)

•  Shelf life 

Up to 7 years (when shipped from factory in Deep Sleep mode)

•  Replacement 

User replaceable (annual recommended)

•  Use Life 

1 year or 300 dive hours if (2) 1 hour dives per dive day

Battery  Icon:

 

•  Warning >> icon on solid when <= 2.75 volts, Battery change recommended

•  Alarm >> icon on flashing when <= 2.50 volts, change the Battery, will not function as a DC 

Operating Temperature:

•  Out of the water >> between 20 °F and 140 °F (-6 and 60 °C).

•  In storage case provided >> between 14 °F and 158 °F (-8 and 70 °C).

•  In the water >> between 28 °F and 95 °F (-2 and 35 °C).  

BAR GRAPHS

 

TLBG

 

  segments   

  O2BG

         segments

•  No Deco Normal zone 

  3          •  Normal zone    3   

•  No Deco Caution zone 

  1          •  Caution zone    1   

•  Decompression zone 

  1          •  Danger zone    1 

 

VARI

 

60 FT (18 M) & Shallower          Deeper than 60 FT (18 M) 

   

 

   

segments    FPM   

MPM      segments      FPM    MPM

   

  0      0 - 10  

0 - 3       

0        0 - 20   0 - 6 

•  Normal Zone 

  1      11 - 25 

3.5 - 7.5     

1        21 - 50  6.5 - 15

•  Caution Zone 

  2      26 - 30 

8 - 9       

2        51 - 60  15.5 - 18

•  Too Fast Zone (flashing) 

  3 (all)    > 30   

> 9       

3 (all)      > 60    > 18

SPECIFICATIONS

Summary of Contents for OCS

Page 1: ...1 OCS OPERATING MANUAL 2002 Design 2011 Doc No 12 5272 r01 9 28 11 OCS DIVE COMPUTER OPERATING MANUAL...

Page 2: ...Set Wet Activation 22 Set Units 22 Set Deep Stop 22 Set Safety Stop 22 Set Algorithm 22 Set Conservative Factor 23 Set Glo Backlight Duration 23 Set Sampling Rate 23 Select Dive Mode 23 NORM GAUG Hist...

Page 3: ...No 12 5272 2002 Design 2011 San Leandro CA USA 94577 TRADEMARK TRADE NAME AND SERVICE MARK NOTICE Oceanic the Oceanic logo type OCS the OCS logo Diver Replaceable Batteries Graphic Diver Interface Ti...

Page 4: ...4 OCS OPERATING MANUAL 2002 Design 2011 Doc No 12 5272 r01 9 28 11 Welcome to OCEANIC and THANK YOU for choosing the OCS...

Page 5: ...5 OCS OPERATING MANUAL 2002 Design 2011 Doc No 12 5272 r01 9 28 11 FEATURES AND FUNCTIONS...

Page 6: ...est compass O2 Oxygen OTR O2 DTR PO2 Partial Pressure of O2 ATA REF Reference compass S South compass SAFE Safety stop SE Southeast compass SEC Seconds time SET A Set Alarms SET F Set FO2 items SET U...

Page 7: ...t First selection and a Stop Last selection Upon entering a Menu movement through it starts at the Start First selection then continues in a rolling manner down the screen showing selections in groups...

Page 8: ...RF ALT 2 Light A 2 sec Select Fly Log Set A Set U Dive Mode History SN 2 sec 2 sec COMPASS MODE STRUCTURE COMP OP MAIN M S A L 2 sec 2 sec closure Watch or DC Main COMP Menu REF Menu Set Reverse Light...

Page 9: ...EE Dive Elapsed Dive Time Alarm 3 beeps every 30 seconds if set On FREE Dive Depth Alarms 1 2 3 set sequentially deeper each 3 beeps 3 times FREE Dive TLBG Alarm Caution zone 4 segments 3 beeps 3 time...

Page 10: ...the Battery is changed or voltage cannot sustain operation then the graphic CHANGE BATTERY flashes Fig 2 until the Battery is changed or voltage drops to the level at which operation cannot be mainta...

Page 11: ...11 OCS OPERATING MANUAL 2002 Design 2011 Doc No 12 5272 r01 9 28 11 WATCH MODE...

Page 12: ...ves A 2 sec to access Watch ALTs M 2 sec to access Watch Menu M 2 sec to access DC Dive Computer Mode S 2 sec to silence Daily Alarm S 2 sec to access Compass L press to activate Backlight Alt 1 infor...

Page 13: ...recall Laps 1 to 9 repeat to recall other Laps Fig 14 A 2 sec to reset Timer to 0 00 00 00 and revert to the Chrono Status screen While the Chronograph is running it remains on the screen until anoth...

Page 14: ...ne previously set for ALT Time Graphics SEt and ALT TIME solid Set Point graphic OFF or the numeric Hour Differential with graphic HR all flashing A hold to scroll upward through Set Points at a rate...

Page 15: ...Set Points one at a time S 2 sec to save the Date Set Point and revert to the Set Time Menu SUMMARY OF WATCH MODE OPERATIONS closure ALT 1 Light Menu CDT Chrono Daily AL Set Time Watch Time Default M...

Page 16: ...16 OCS OPERATING MANUAL 2002 Design 2011 Doc No 12 5272 r01 9 28 11 NORM SURFACE MODES...

Page 17: ...n Surface Modes operation will enter the Dive Mode selected upon descent to 5 FT 1 5 M for 5 seconds When Wet Activation is set OFF Dive Mode will only be activated during operation in a DC Mode It wi...

Page 18: ...n O2BG with O2 icon if any after a dive 5 sec or A 2 sec to revert to Main L press to activate Backlight NORM MENU M 2 sec to access Menu while viewing Surface Main A 2 sec to step down forward throug...

Page 19: ...value set for Gas 1 1 20 to 1 60 if Nitrox blank if set for Air Nx icon if Nitrox A hold to scroll upward through screens at a rate of 8 per second increasing planned Depth from 30 to 190 FT 9 to 57...

Page 20: ...or repetitive dives When FO2 is set for Nitrox The Air option will not be displayed as an FO2 setting until 24 hours elapse after the last dive When FO2 is set for OFF Gas 2 3 That Gas will not be ava...

Page 21: ...or if no button is pressed during a 2 minute period SET GAS 3 FO2 PO2 is similar to SET GAS 2 Once any Gas is set for Nitrox any other Gas set for Air will automatically be set to 21 SET FO2 50 DEFAU...

Page 22: ...ics ON and OFF Arrow icon next to the one previously saved flashing A 2 sec to toggle Set Points S 2 sec to save the setting and revert to the Set U Menu Set Units information includes Fig 46 Graphic...

Page 23: ...lection Arrow icon is next to it on the NORM Menu Information includes Fig 53 Graphic SEL Select Graphics NORM MODE GAUG MODE and FREE MODE Arrow icon next to mode currently active A 2 sec to step upw...

Page 24: ...24 OCS OPERATING MANUAL 2002 Design 2011 Doc No 12 5272 r01 9 28 11 DIVE MODE FEATURES...

Page 25: ...us and the fifth at the top indicates a Deco condition As your Depth and Elapsed Dive Time increase seg ments add and as you ascend segments recede indicating that additional no deco time is available...

Page 26: ...o Deco dive in which Depth exceeded 30 FT 9 M for 1 second the audible will sound and a SS at the Depth set will be displayed with a countdown beginning at the SS Time set and counting down to 0 00 mi...

Page 27: ...Nitrogen absorbed by hypothetical tissue compartments The rates each of these compartments absorb and release Nitrogen is mathematically modeled and compared against a maximum allowable Nitrogen leve...

Page 28: ...28 OCS OPERATING MANUAL 2002 Design 2011 Doc No 12 5272 r01 9 28 11 NORM DIVE MODES...

Page 29: ...5 sec if A not pressed No Deco Alt 2 information includes Fig 69 Time of Day hr min sec with A or P if 12 Hour Temperature with icon and graphic F or C 5 sec or A 2 sec revert to Main Deep Stop Previ...

Page 30: ...2 sec to access ALT 2 Revert to Main in 5 sec if A is not pressed Safety Stop Alt 2 information includes Fig 77 Time of Day hr min sec with A or P if 12 Hour Temperature with icon and graphic F or C...

Page 31: ...ing credit will be given with remaining Deco Stop Time and TAT freezing The Audible will sound and the LED will flash The full TLBG and Down Arrow icon will flash Fig 82 until the Audible is si lenced...

Page 32: ...ng A 2 sec to access ALTs S 2 sec to acknowledge alarms S 2 sec to access Compass L press to activate Backlight DV3 Alt 1 information includes Fig 86 Max Depth as 3 dashes with FT or M and MAX icons E...

Page 33: ...ll flash in place of NDC until the Audible is silenced Fig 93A After the Audible NDC is restored the graphic WARNING and Up Arrow icon remain on solid until PO2 decreases below 20 less than the Alarm...

Page 34: ...light O2 Alarm Main information includes Fig 98 Up Arrow icon flashing until on surface Current Depth with FT or M icon Graphic O2 flashing in place of DTR until on surface Graphic ALARM on solid unti...

Page 35: ...atly increase your risk of decompression sickness Decompression diving is inherently hazardous and greatly increases your risk of decompression sickness even when performed according to the dive compu...

Page 36: ...36 OCS OPERATING MANUAL 2002 Design 2011 Doc No 12 5272 r01 9 28 11 GAS SWITCHING...

Page 37: ...selection the Switch To screen indicated by Arrow icon No access provided if OFF GAS Switch To information includes Fig 102 Graphics SWCH TO GAS1 or 2 or 3 Graphic FO2 with Set Point Graphic PO2 with...

Page 38: ...2 sec Watch Mode Compass S 2 sec M 2 sec A 2 sec M or S 2 sec FLY LOG SET A SET U DIVE MODE HISTORY SN M 2 sec access selection ALTs DIVE at 5 FT 1 5 M for 5 sec at 2 FT 0 6 M for 1 sec Surface Mode D...

Page 39: ...39 OCS OPERATING MANUAL 2002 Design 2011 Doc No 12 5272 r01 9 28 11 DIGITAL GAUGE OP MODE...

Page 40: ...Backlight GAUG MENU M 2 sec to access Menu while viewing Surface Main A 2 sec to step down forward through selections M 2 sec to step up back through selections S 2 sec to access selection indicated...

Page 41: ...will only indicate 3 dashes signifying that you are Out of Range Upon ascending above 660 FT 200 M Current Depth will be restored however Max Depth on ALT 1 will display 3 dashes for the remainder of...

Page 42: ...42 OCS OPERATING MANUAL 2002 Design 2011 Doc No 12 5272 r01 9 28 11 FREE DIVE OP MODE...

Page 43: ...vious dive Graphic LAST DIVE indicating that data is from the dive previously conducted while in FREE mode A 2 sec to access ALT 2 10 sec revert to Main if A is not pressed L press to activate Backlig...

Page 44: ...e M 2 sec to step back through Set Points one at a time S 2 sec to save the CDT Set Point and revert to the CDT Status screen with SET flashing similar to Fig 127B S 2 sec to revert to FREE Menu The C...

Page 45: ...accessed when DD2 is set Off a message Fig 133B will be displayed for 5 seconds then operation will revert to the FREE Menu A hold to scroll up through Depth values at a rate of 8 per second beginning...

Page 46: ...nts down to 0 00 or it is turned OFF FREE DIVE ALT 2 information includes Fig 137 Time of Day hr min sec with A or P if 12 Hour Temperature with icon and graphic F or C 5 sec or A 2 sec revert to Main...

Page 47: ...e surface In the event that nitrogen continues to increase and reaches the Deco level Fig 142A all 5 TLBG segments the Up Arrow icon and the graphic VIOL will flash while the Audible sounds NDC will b...

Page 48: ...48 OCS OPERATING MANUAL 2002 Design 2011 Doc No 12 5272 r01 9 28 11 COMPASS MODE...

Page 49: ...to OP Main rotate level Set Declin OFF EAST WEST S 2 sec S 2 sec save back to Compass Menu S 2 sec Set 0 to 45 S 2 sec Battery Change DATA A 2 sec to toggle S 2 sec DATA SAVED CAL COMPASS after beep...

Page 50: ...with FT or M icon during dive mode 00 during first 10 min on surface blank on surface 10 min North Mode icon letter N in box Static Arrow icon at 12 o clock diver direction of travel Dynamic Arrow re...

Page 51: ...vate start Calibration Slowly and steadily rotate the unit 360 in either direction while maintaining it in a flat level position keeping it level is critical for acurracy CAL progress will be displaye...

Page 52: ...will be terminated and the Dive Main will be displayed indicating the alarm condition Compass Mode can then be reentered by pressing S 2 sec During several types of alarms indication will be given whi...

Page 53: ...TION When the procedure provided in this section is used to change the Battery you must be sure that the case o ring is not pinched and that the OCS is water tight before conducting diving activities...

Page 54: ...nal Computer with USB Port Intel Pentium 200 MHz or better microprocessor Microsoft Windows XP Vista or 7 Super VGA card or compatible video graphics adaptor 256 color or greater with a minimum 800 X...

Page 55: ...losely adhered to avoid entrance of water into the unit Damage due to improper Battery replacement or subsequent leakage of moisture into the unit is not covered by the OCS s 2 year warranty NOTE The...

Page 56: ...selections SAVE and CLEAR will be displayed Fig 172 giving you the option to retain or delete Ni O2 calculations for repetitive dives A 2 sec to toggle between SAVE and CLEAR S 2 sec to save the sele...

Page 57: ...57 OCS OPERATING MANUAL 2002 Design 2011 Doc No 12 5272 r01 9 28 11 TECHNICAL DATA...

Page 58: ...0 03 54 0 05 0 04 0 04 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 57 0 05 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 DSAT ALGORITHM NDLS HR MIN AT ALTITUDE IMPERIAL Altitude 0 3001 4001...

Page 59: ...der dive Altitude Operational from sea level to 14 000 feet 4 270 meters elevation Measures ambient pressure every 30 minutes in Watch Mode when Dive Computer Mode is accessed and every 15 minutes whi...

Page 60: ...200 M 1 FT 0 1 1 M NORM GAUG EDT 0 00 to 9 59 hr min 1 minute NORM DTR NDC OTR 0 00 to 9 59 hr min 1 minute FO2 Set Points Gas 1 2 3 Air 21 to 100 1 PO2 Value Gas 1 2 3 0 00 to 5 00 ATA 01 ATA No Deco...

Page 61: ...nic Dealer Date Service Performed Dealer Technician OCEANIC WORLD WIDE OCEANIC USA 2002 Davis Street San Leandro CA 94577 Tel 510 562 0500 Fax 510 569 5404 Web www OceanicWorldwide com E mail hello oc...

Page 62: ...62 OCS OPERATING MANUAL 2002 Design 2011 Doc No 12 5272 r01 9 28 11 OCS DIVE COMPUTER OPERATING MANUAL...

Reviews: