heater element, the stones should plainly cover the heater element (refer to Pile stones fig8). The 

diameter of stone is about 3-8cm.

Rearrange the stones in the heater at least once a year or twice if it is in frequent use (maximum 

500 hrs). To decide the correct volume of stones in heater, refer to table 1 (Technical parameter ) 

provided.

8.9.  9. Insulation 

The door, ceiling and walls of sauna room must be insulated.  For every square meter of wall panel 

that is not insulated the size of cabin should decrease by 1.3 cubic meters in relation to the model 

of heater. Refer to table 1.

Ensure insulation is water proofed to prevent moisture spreading to the other rooms or wall 

structure .  Moisture-proofing must be placed between panel and heating insulation.

Moisture and thermal proofing should be installed from outside to inside, such as:

i.  Recommend that the MIN thickness of the thermal insulation in the walls in 50mm and in the 

ceiling 100mm.

ii.  Aluminum foil laminate is affixed over the heating insulation as a moisture-proof. 

iii.  Leave at least 20mm air slot between moisture-proof Aluminum foil and inside panel.

iv.  Leave a slot between wall panel and ceiling to prevent gathering vapor.

8.10.  10. 

Air ventilation of sauna room 

•  Mix the cold air with hot air to relieve mugginess when bathing.

•  Draw the fresh air around the heater to ventilate the sauna room.

•  Move the heater air to the farthest part of sauna room considering air ventilation of sauna 

room, the inlet and outlet vent should be installed. 

The inlet vent may be installed on the wall below the heater. (fig 15a).when using mechanical 

ventilation ,inlet vent is placed 50cm above the heater (fig 15b) or on the ceiling above the heater 

(fig 15c).the heavy cold air that blown into sauna room is mixed with the light not air from the 

heater ,bringing fresh air for bathers. The recommended inlet should have a diameter of 5—10cm.

The outlet vent should be placed diagonally opposite to the inlet. It is advised the outlet vent is 

placed under the platform in sauna room as far as possible from the inlet vent. It can be installed 

near the floor, or lead outside through a pipe from the floor going to a vent to the sauna ceiling, 

or under the door (to the wash room). In this case, the sill slot must be at least 5cm and it is 

recommended there is mechanical ventilation in washroom the size of the outlet should be twice 

of the inlet. 

 Warning: 

Summary of Contents for OCS B Series

Page 1: ...RODUCT IMAGE Oceanic Ltd Pountney Street Wolverhampton WV2 4HX Phone 01902 450 550 sales oceanic saunas co uk www oceanic saunas co uk Sauna Steam HEAVY DUTY SAUNA HEATER Assembly and operating manual...

Page 2: ...Temperature Sensor 8 6 1 Parts Description 8 6 2 Temperature Sensor Parameters 8 7 Installation 9 7 1 Minimum Clearances 10 7 2 Installation for sauna heater 11 7 3 Installation for controller 11 7 4...

Page 3: ...Risk of fire Do not operate sauna heater without sauna stone Do not touch the heater when operational as it is very hot When this heater is used in an unsupervised and or public location with the adva...

Page 4: ...1 5 40 50 L 480 W 560 H 660 0CS105B 10 5 3 1 5 H1 H3 H5 3 2 0 H2 H4 H6 9 15 400 3N Terminal1 5 1 5 Terminal2 5 1 5 40 50 0CS120B 12 0 6 2 0 H1 H6 10 18 400 3N Terminal1 5 2 5 Terminal2 5 2 5 40 50 0CS...

Page 5: ...agram for sauna heater and control Box i Sauna heater circuit diagram OC SA I 230V 230V 3 4 248 217 78 OC SA II 230V 400V 230V 400V 4 5 9 280 217 78 Model Input Output Load power Size mm 3N 3N Kw L W...

Page 6: ...ntroller AC400V 3N 50 60Hz OCS B Control box circuit diagram Terminal 1 Voltage DC5V Fan AC230VAC230V Max Output Power 12kw Max Output Power 12kw Light Terminal 2 W W V V U U N N L N F N L3 L2 L1 N Te...

Page 7: ...tions 7 1 Sauna heater frame and parts No parts description 1 Heat element heating 2 Shell Insulate the inner shell to prevent from scalding 3 Cover Panel Cover the electrical parts 4 terminal Connect...

Page 8: ...he door is open the default is the connection switch is downward opposite side of ON when the door is open there is on signal to circuit board the LED is on and sauna heater stop work Such as on sauna...

Page 9: ...n Function instruction 1 Wire anchorage Route of wire entry and fasten wires 2 terminal Connect to the power supply 3 Terminal Connect to heater 4 Heater light and fan output Outlet of wires to heater...

Page 10: ...ven in Fig 7 and chart 8 and allow for safety and convenience Is the controller special electrical box suitable for the heater power and control requirements Choose the cable wire according to table 1...

Page 11: ...B min Model Safety Distance mm A B C D E min max min min min min OCS090B 120 220 100 200 1200 630 OCS120B 120 220 100 200 1200 630 OCS150B 160 260 100 200 1200 630 8 2 Installation of sauna heater Re...

Page 12: ...hould be installed at a height of approximately 1200mm for ease of use Installation method Drill a 40mm diameter hole through the wall Pull the front off the keypad you may find it easier with a small...

Page 13: ...re sensor i Install the temperature sensor as in the diagram opposite ii Open the cover with a screwdriver iii Fix the bottom of the temperature sensor on to wall with screw iv Replace the cover OC SB...

Page 14: ...ace around the heater by drilling screwing accordingly Note It is important that the top rail of the guard is set at least 30 mm below the rim of the heater such that it does not receive heat radiatio...

Page 15: ...at least 20mm air slot between moisture proof Aluminum foil and inside panel iv Leave a slot between wall panel and ceiling to prevent gathering vapor 8 10 10 Air ventilation of sauna room Mix the col...

Page 16: ...g and bathing the sauna room can also be dried by leaving the door open after bathing 5 If there is only an exhaust vent in washing room leave an opening MIN CM Under the sauna door Mechanical ventila...

Page 17: ...ant the sauna to start heating up half way through so its ready at the end of the film you can use the B model setting which can be set if you press the MENU ENTER and the time window will display 4 0...

Page 18: ...If the power supply indicator LED L1 red is on check the wire 2 Change the controller The controller is on but the sauna heater doesn t work 1 The sauna heater hasn t been connected 2 There is a prob...

Page 19: ...le is broken 2 The temperature is lower than 0o C 3 The temperature is higher than 115o C 1 Lo C means temperature sensor hasn t connected or the temperature is lower than 0o C check the connection ca...

Page 20: ...repair For commercial users we recommend these inspections be conducted on a monthly basis by a member of the maintenance staff and detailed records kept For domestic use these checks should be carri...

Reviews: