![Oceanic OCi Operating Manual Download Page 25](http://html1.mh-extra.com/html/oceanic/oci/oci_operating-manual_3297001025.webp)
25
OCi OPERATING MANUAL
© 2002 Design, 2013
Doc. No. 12-5335-r02 (9/12/13)
SET SAFETY STOP (No Deco only),
information includes (Fig. 46A/B):
> Graphics SAFE STOP.
> Graphics OFF, ON, TMR (Timer); last saved fl ashing upon access.
> Stop Depth & Time (min) with icons, last values set.
• S (2 sec) - to revert to the Set Utilities Menu without changing the setting.
• A (< 2 sec) - to step forward (down screen) through the selections OFF, ON, TMR, SET.
• M (< 2 sec) - to step back (up screen) through the selections.
• S (< 2 sec) - save the selection.
>> If OFF, ON, or TMR* is selected, operation reverts to the Utilities Menu.
>> If SET is selected, the Time digits will fl ash.
*
Choosing TMR (Timer) allows you to determine at which depth you will perform the safety stop while a run timer counts the
time spent at the stop. The Depth and Time displayed on the set screen only applies when ON is selected.
• A or M (< 2 sec) - to toggle Stop Time between 3 and 5 (minutes).
• S (< 2 sec) - to save the Time setting and fl ash the Depth digits.
• A (< 2 sec) - to step forward through Depth set points of 10, 15, 20 FT (or 3, 4, 5, 6 M).
• M (< 2 sec) - to step back through Depth set points one at a time.
• S (< 2 sec) - to save the Time/Depth setting (digits solid) and fl ash SET allowing OFF, ON, or TMR to be selected/saved.
• M (2 sec), or 2 min of no button action, - to revert to the Surface Main.
SET ALGORITHM,
information includes (Fig. 47):
> Graphic ALGO (Algorithm).
> Graphics DSAT and Z+, last one saved fl ashing.
• S (2 sec) - to revert to the Set Utilities Menu without changing the setting.
• A or M (< 2 sec) - to toggle between DSAT and Z+.
• S (< 2 sec) - to save the setting and revert to the Set Utilities Menu.
• M (2 sec), or 2 min of no button action, - to revert to the Surface Main.
>> This feature allows selection of the algorithm used for nitrogen and oxygen calculations.
>> Z+ is more conservative allowing shorter No Deco times at specifi c depths. Refer to page 31.
>> Changing the algorihm is blocked during 24 hours after NORM and FREE dives unless Desat time decreases to 0:00.
SET CONSERVATIVE FACTOR,
information includes (Fig. 48):
> Graphic CONS FACTOR (Conservative Factor).
> Graphics OFF and ON, last one saved fl ashing.
• S (2 sec) - to revert to the Set Utilities Menu without changing the setting.
• A or M (< 2 sec) - to toggle between OFF and ON.
• S (< 2 sec) - to save the setting and revert to the Set Utilities Menu.
• M (2 sec), or 2 min of no button action, - to revert to the Surface Main.
When set On, NDLs are reduced to those of the next higher 3000 foot (915 meter) Altitude. Refer to the charts in the back.
SET BACKLIGHT DURATION,
information includes (Fig. 49):
> Graphics GLO DURA (Glo = Backlight, Duration).
> Graphics OFF, ON, and SET; last saved (OFF or ON) fl ashing upon access.
> Time (5, 10, 30, 60), last value saved fl ashing with graphic SEC (seconds).
• S (2 sec) - to revert to the Set Utilities Menu without changing the setting.
• A (< 2 sec) - to step forward (down screen) through the selections OFF, ON, SET.
• M (< 2 sec) - to step back (up screen) through the selections.
• S (< 2 sec) - save the selection.
>> If OFF or ON is selected, operation reverts to the Utilities Menu.
>> If SET is selected, the Time digits will fl ash.
• A (< 2 sec) - to step upward through set points 5, 10, 30, and 60 (seconds), one at a time.
• M (< 2 sec) - to step back through set points one at a time.
• S (< 2 sec) - to save the setting with the Time digits solid and SET fl ashing allowing ON or OFF to be selected.
• M (2 sec), or 2 min of no button action, - to revert to the Surface Main.
Backlight Duration is the additional time the Backlight will remain On after the L button is released.
Fig. 48 - SET CONSERVA-
TIVE FACTOR
Fig. 49 - SET BACKLIGHT
DURATION
Fig. 46B - SET SAFETY STOP
(set Time then Depth)
Fig. 46A - SET SAFETY STOP
Fig. 47 - SET ALGORITHM
Summary of Contents for OCi
Page 5: ...5 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 FEATURES AND FUNCTIONS...
Page 11: ...11 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 WATCH MODE...
Page 16: ...16 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 NORM SURFACE MODES...
Page 28: ...28 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 DIVE MODE FEATURES...
Page 33: ...33 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 NORM DIVE MODE...
Page 40: ...40 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 NORM GAS TMT SWITCHING...
Page 42: ...42 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 DIGITAL GAUGE OP MODE...
Page 61: ...61 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 COMPASS MODE...
Page 70: ...70 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 TECHNICAL DATA...