21
•
Detach the grid.
•
Replace the CF152 charcoal
filter.
REPLACING
THE BULB
Important:
The bulb must be replaced
by the manufacturer, its service
agent or a qualified person.
Always turn off the power
before performing any
operations on the unit. While
handling the bulb, make sure it
is completely cool before direct
contact with your hands.
When handling the bulb,
always use a cloth or gloves
to make sure that perspiration
does not come in contact with
the bulb as this can reduce its
life.
Replacing the lamp:
• Unscrew the two self-tapping
screws ST4 * 8 mm from the
lighting panel. Take the lamp
out of its fastener.
• Remove the 3 screws ST3 *
12 mm from the terminal
block cover, and remove the
wire cover.
• Remove the terminal from
the PCB terminal block,
disconnect the connector
wire, and replace the lamp.
Note: Make sure that the power
is completely turned off before
the operation above.
The ILCOS D code for this
lamp is: DBS-2.5 / 65-H-
120/33
- LED modules - rectangular
lamp
- Maximum power: 2.5 W
- Voltage range: AC 220-240 V
- Dimensions:
Maintenance and cleaning