background image

Oceanic Saunas  01902 450 550  [email protected]

10

No

Part

Description

1

On/off 

Push to turn the equipment on or off

2

Light

Push to turn on the light in the room. 

3

Fan / Music

Push once to turn on fan (not required) Push twice to turn on speakers

4

Set

Preset time and temperature - 

(you must then press ‘Enter’ to save settings)

5

/\

Increase button 

6

\/

Decrease button

7

Enter / Steam

Press Enter to save settings. Steam function not required 

8

Time display window

Display the work time of the steam generator

9

Temp display window

Display the detected temperature of steam room 

10

Steam

Not used

11

Fan

Indicated the Fan is active (not required for Oceanic IR sauna)

12

Music

Indicated the Speakers have been turned on

13

Light

Indicated the Light is turned on

14

Chromo

Light to indicate secondary lighting circuit

15

Overheat

Indicator LED for overheat - turn machine off and wait for 1 hour before 

switching back on, if problem persists contact the seller.  

16

L7

Indicates the detected temperature is lower than the preset temperature and 

sauna heater is heating.

17

L8

Indicates the detected temperature is higher than the preset temperature and 

the sauna heater is idling.

Steam

Fan

Music

Light

Chromo

Overheat

Enter

Steam

OC-ST

TIME

TEMP

Fan

Music

Light

Chromo

Set

1

2

3

4

7

5

6

17

8

9

16

15

14

13

12

11

10

On

Off

8.  Keypad Functions

Summary of Contents for OC-Mini-1

Page 1: ...Sauna Steam Oceanic Ltd Pountney Street Wolverhampton WV2 4HX Phone 01902 450 550 sales oceanic saunas co uk www oceanic saunas co uk Infrared Heaters and Control System...

Page 2: ...1 Example Layout 5 4 Installing Heater Units 6 4 1 Vertical Units 6 4 2 Under Bench Heaters 7 4 3 Lighting 7 5 Speakers 8 6 Audio Input AUX 8 7 Circuit Diagram 9 8 Keypad Functions 10 9 Keypad Operati...

Page 3: ...h blood pressure diabetes or not in good health are advised to seek medical opinion before using a sauna room Do not smoke in the sauna room Avoid using the sauna room immediately after strenuous exer...

Page 4: ...socket as the total power is limited to 8 units 2400W The commercial unit must be wired via an isolator switch and can power upto 12 heater units 3600W 2 4 Keypad The oval shaped keypad is supplied w...

Page 5: ...ayout Drawings below show the layout of the system from our D1020 IR Sauna Cabin see website for further details and images Vertical IR Heater Horizontal IR Heater Backrest Vent Temperature Sensor Pla...

Page 6: ...vertical heater drill a 50mm hole at 567mm from the floor in the wall cladding for the power cable to feed through iii Pilot and drill 2 x 30mm screws at 82mm centres 1169mm from floor level suggeste...

Page 7: ...ut AUX 4 3 Lighting It is possible to connect up to 3No 12V spotlights to the lighting input on the control box LED versions which are suitable for Infrared saunas only are available to buy from Ocean...

Page 8: ...cable as standard 5 Speakers Speakers are available from the Oceanic website A bluetooth device is also to purchase available if you prefer to connect via bluetooth Simply plug the speaker wires into...

Page 9: ...Oceanic Saunas 01902 450 550 sales oceanic saunas co uk 9 7 Circuit Diagram...

Page 10: ...team room 10 Steam Not used 11 Fan Indicated the Fan is active not required for Oceanic IR sauna 12 Music Indicated the Speakers have been turned on 13 Light Indicated the Light is turned on 14 Chromo...

Page 11: ...a session iv Adjusting the temperature Press the Set button twice The temperature will now start flashing Increase or decrease using the blue and red arrow keys Once correct press the Enter button to...

Page 12: ...uipment must be installed vertically ii Stop pouring water into the boiler when the high level LED light A turns on Don t let the water reach the holes in the top cover You can release water using the...

Page 13: ...m outlet and water inlet 13 Shell 14 Heat preservation cotton 9 5 Installation i Position the steam generator on a blank wall panel at low level 150 300mm above ground level ii Fix to cabin wall using...

Page 14: ...not add neat aroma to the tank ensure the aroma is diluted Oceanic aromas are to be diluted 1 part aroma to 20 parts water For every 1ltr of water only add a maximum of 50ml of aroma ix Ensure you dr...

Reviews: