background image

Monthly Maintenance           
(Figures C12–C14)

1.   Replace used filter cartridge by tilting the 

filter back from one end of the overflow 
tray, then pulling out. Discard. Rinse new 
filter cartridge with freshwater before 
installing (Figure C12).

2.  Remove sponge filter from water pump. 

Rinse and clean sponge with cool 
freshwater to remove accumulated organic 
buildup (Figure C13).

3.  Disconnect water pump from output elbow 

attachment and flexible tubing. Disassemble 
pump and impeller. Rinse and wipe down all 
parts to dislodge debris. If calcium buildup 
is present, soak in a vinegar solution with 
one part vinegar to one part water for one 
hour, then rinse thoroughly.

4.  Disassemble pump and impeller. Rinse    

and wipe down all parts to dislodge debris 
and particulate matter (Figure C14).

9–12 Month Maintenance

1.   Replace Aqualight HQI metal halide bulb 

every 9-12 months by following the lamp 
replacement instructions on page 14.        
For optimal performance, always use 
Coralife brand 150 Watt Double-Ended   
HQI replacement lamps.

BIOCUBE MAINTENANCE 

(con't)

Filter Cartridge

Overflow Tray

Pump Housing

Pump Impeller

Ceramic Shaft

Impeller Cover

Sponge Filter

FIGURE C12

FIGURE C13

FIGURE C14

ti

lt

 u

p

Pull a

way

WARNING!

1.   Make sure all switches are in the off position 

and unplug power cords from power source 
or outlet before performing maintenance.

2.  Wash hands thoroughly with soap and 

water before performing maintenance        
to avoid contamination of the aquarium.

Daily Maintenance (Figure C11)

1.   Visually observe the BioCube lighting and 

filtration to make sure that the system is 
functioning properly.

2.  Check water level. Make sure to replace 

evaporated water with freshwater to 
replenish water supply. 

Do not let water  

get below the minimum water level.

Weekly Maintenance

1.   Keep BioCube surfaces clean from dust and 

debris. Wipe exposed surfaces with a clean 
and dampened soft terrycloth.

2.  Remove glass top and wipe down with a 

dampened soft terrycloth to remove salt 
buildup.

3.  Inspect filtration system for clogging and 

excessive accumulation of debris. Clean and 
remove debris from surface and bottom 
intakes and overflow tray. Rinse parts in 
freshwater if needed.

BIOCUBE MAINTENANCE

Minimum

Water Level

FIGURE C11

26

27

Summary of Contents for BioCube HQi

Page 1: ...RRANTIES UNDER THIS LIMITED WARRANTY ALL SUCH WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY OCEANIC I...

Page 2: ...tt 14 000K double ended metal halide Cooling Fans 38 mm 4 000 RPM Pump Flow Rate 243 gph 920 L H Page 4 Important Safety Instructions Page 6 Grounding Page 7 BioCube HQI Assembly and Setup Instruction...

Page 3: ...ause algae growth 4 Keep aquarium in a well ventilated area away from a heating or cooling vent 5 Do not place near electronic components and systems i e TV stereo systems etc IMPORTANT SAFETY INSTRUC...

Page 4: ...e like extending from the adapter must be fastened to a permanent ground such as a grounded outlet box 1 Plug temporary adapter into two pole outlet Figure A4 2 Insert screw through rigid ear on tempo...

Page 5: ...ion Cover 2 Right Filtration Cover 3 Glass Canopy 4 Filter Cartridge 82105 5 Overflow Tray 6 Output Elbow Attachment 7 Flexible Tubing 8 Water Pump 82007 9 Output Discharge Nozzle 10 BioCube Glass Aqu...

Page 6: ...tion 1 Collection Cup Lid 2 Collection Cup 3 Reaction Chamber Top 4 Suction Cup 5 Airstone 6 Reaction Chamber Assembly 7 Airline Tubing 7 8 Air Pump 9 Inline Air Flow Valve 10 Check Valve PROTEIN SKIM...

Page 7: ...wall between chambers 1 and 2 NOTE if skimmer is in correct position the right filtration cover will fit properly Collection Cup Assembly Figure C3 1 Place collection cup on top of reaction chamber P...

Page 8: ...Add substrate rocks and d cor to the aquarium 2 Prepare saltwater for aquarium making sure water is at room temperature 3 Slowly add water to the aquarium Make sure to fill aquarium to the lower edge...

Page 9: ...ith the refugium light to mount to BioCube HQI REFUGIUM SETUP AND REFUGIUM LIGHT INSTALLATION FIGURE C7 BioCube Filtration Stages Figures C8 C10 1 Water flows from aquarium into the surface and bottom...

Page 10: ...Aqualight HQI ASSEMBLY AND SETUP INSTRUCTIONS AQUALIGHT HQI PARTS DIAGRAM 1 18 19 16 15 17 2 3 4 5 6 7 8 9 10 14 11 12 13 18 19...

Page 11: ...ket Connection B with female connection knob using height adjustment knob 2 Screw height adjustment knob through Connection B and into Connection A 3 Adjust and secure connection Safety Precautions 1...

Page 12: ...n connector on fixture 2 Attach cooling fan connector to cooling fan adaptor BALLAST AND COOLING FAN SETUP MALE FEMALE Double ended HQI Metal Halide Lamp Connector Double ended HQI Metal Halide Ballas...

Page 13: ...HQI metal halide lamp with fingers as the oils may damage the lamp If contact is made with the lamp use a clean soft dry cloth to remove any fingerprints from the lamp before use LAMP REPLACEMENT Lam...

Page 14: ...s BIOCUBE MAINTENANCE con t Filter Cartridge Overflow Tray Pump Housing Pump Impeller Ceramic Shaft Impeller Cover Sponge Filter FIGURE C12 FIGURE C13 FIGURE C14 t i l t u p Pull away WARNING 1 Make s...

Reviews: