stones may smoke slightly and give off a smell – please ensure the sauna cabin is well ventilated.

• 

Connect to power supply, press “  “key, temp and time windows will display data, LED shows 

the sauna’s heating status when the light is on, the temperature of sauna room will rise and will 

achieve the preset temperature (the default settings are 70 ℃/158℃, work time is 2 hours) chart 9

9.2.  Setting time and temperature:

• 

The default settings for temperature are: 75

o

C/167

o

F. For preset operation time:  2 hours. These 

can be adjusted easily, if the electricity supply is lost the controller will return to default settings. 

• 

When the sauna is turned on the time settings will work under A model (A model LED is on), 

the time window will display the last time that was set. Press” SET” key the time display window will 

flash. press “

p

 ” or “

q

 ” to adjust the time, every press the time will increase or reduce 10 minutes. 

once the desired setting is reached press “ MENU/ENTER”  the window will stop flashing. You can 

adjust from the time from 10 minutes to 8 hours.  Note the controller has a memory function, if the 

power supply is not cut off the next time you turn on sauna the time you selected will be the default 

time.

• 

To set your heater to come on at a certain time (for example: if you plan to watch a film and 

want the sauna to start heating up half way through so its ready at the end of the film) you can use 

the B model setting which can be set if you press the  “MENU/ENTER”” and the time window will 

display 4:00, now Press” SET” key the time display window will flash. press “

p

 ” or “

q

 ” to adjust the 

time, every press the time will increase or reduce 10 minutes. once the desired setting is reached 

press “MENU/ENTER ”  the window will stop flashing., when it reaches “0” it will switch over to A Model 

and the heater will turn on. (Remember to set the time you want the heater on for on A Model before 

setting B Model)

• 

For quick time adjustment: hold the  “

p

 ” or “

q

 ”  and it will count continuously up or down, 

when it reaches the time you want release and it will stop. 

• 

Temperature: switch button you can switch between centigrade and Fahrenheit.

• 

To adjust temperature: Press “SET ” once after you finish setting the time or otherwise twice 

the temperature window will flash, enter the required temperature by pressing “

p

 ” or “

q

 ” to adjust 

- every press will increase or reduce 1

O

Cor 2

O

F.you can adjust from 50

o

C-110

o

C 122

o

F-230

o

F once the 

required temperature has been set press “ MENU/ENTER” key  the window will stop flashing. 

 

9.3.  Door Interlock 

When used in commercial situations such as public buildings where the countdown timer is set to 

come on in advance the door interlock switch must be connected as described in Fig 2 – before the 

timer is set to come on in advance the sauna room must be checked by the responsible person to 

ensure there is no hazard such as combustible material left over the sauna stove etc – then the sauna 

Summary of Contents for 0CS090B

Page 1: ...RODUCT IMAGE Oceanic Ltd Pountney Street Wolverhampton WV2 4HX Phone 01902 450 550 sales oceanic saunas co uk www oceanic saunas co uk Sauna Steam HEAVY DUTY SAUNA HEATER Assembly and operating manual...

Page 2: ...Temperature Sensor 8 6 1 Parts Description 8 6 2 Temperature Sensor Parameters 8 7 Installation 9 7 1 Minimum Clearances 10 7 2 Installation for sauna heater 11 7 3 Installation for controller 11 7 4...

Page 3: ...Risk of fire Do not operate sauna heater without sauna stone Do not touch the heater when operational as it is very hot When this heater is used in an unsupervised and or public location with the adva...

Page 4: ...1 5 40 50 L 480 W 560 H 660 0CS105B 10 5 3 1 5 H1 H3 H5 3 2 0 H2 H4 H6 9 15 400 3N Terminal1 5 1 5 Terminal2 5 1 5 40 50 0CS120B 12 0 6 2 0 H1 H6 10 18 400 3N Terminal1 5 2 5 Terminal2 5 2 5 40 50 0CS...

Page 5: ...agram for sauna heater and control Box i Sauna heater circuit diagram OC SA I 230V 230V 3 4 248 217 78 OC SA II 230V 400V 230V 400V 4 5 9 280 217 78 Model Input Output Load power Size mm 3N 3N Kw L W...

Page 6: ...ntroller AC400V 3N 50 60Hz OCS B Control box circuit diagram Terminal 1 Voltage DC5V Fan AC230VAC230V Max Output Power 12kw Max Output Power 12kw Light Terminal 2 W W V V U U N N L N F N L3 L2 L1 N Te...

Page 7: ...tions 7 1 Sauna heater frame and parts No parts description 1 Heat element heating 2 Shell Insulate the inner shell to prevent from scalding 3 Cover Panel Cover the electrical parts 4 terminal Connect...

Page 8: ...he door is open the default is the connection switch is downward opposite side of ON when the door is open there is on signal to circuit board the LED is on and sauna heater stop work Such as on sauna...

Page 9: ...n Function instruction 1 Wire anchorage Route of wire entry and fasten wires 2 terminal Connect to the power supply 3 Terminal Connect to heater 4 Heater light and fan output Outlet of wires to heater...

Page 10: ...ven in Fig 7 and chart 8 and allow for safety and convenience Is the controller special electrical box suitable for the heater power and control requirements Choose the cable wire according to table 1...

Page 11: ...B min Model Safety Distance mm A B C D E min max min min min min OCS090B 120 220 100 200 1200 630 OCS120B 120 220 100 200 1200 630 OCS150B 160 260 100 200 1200 630 8 2 Installation of sauna heater Re...

Page 12: ...hould be installed at a height of approximately 1200mm for ease of use Installation method Drill a 40mm diameter hole through the wall Pull the front off the keypad you may find it easier with a small...

Page 13: ...re sensor i Install the temperature sensor as in the diagram opposite ii Open the cover with a screwdriver iii Fix the bottom of the temperature sensor on to wall with screw iv Replace the cover OC SB...

Page 14: ...ace around the heater by drilling screwing accordingly Note It is important that the top rail of the guard is set at least 30 mm below the rim of the heater such that it does not receive heat radiatio...

Page 15: ...at least 20mm air slot between moisture proof Aluminum foil and inside panel iv Leave a slot between wall panel and ceiling to prevent gathering vapor 8 10 10 Air ventilation of sauna room Mix the col...

Page 16: ...g and bathing the sauna room can also be dried by leaving the door open after bathing 5 If there is only an exhaust vent in washing room leave an opening MIN CM Under the sauna door Mechanical ventila...

Page 17: ...ant the sauna to start heating up half way through so its ready at the end of the film you can use the B model setting which can be set if you press the MENU ENTER and the time window will display 4 0...

Page 18: ...If the power supply indicator LED L1 red is on check the wire 2 Change the controller The controller is on but the sauna heater doesn t work 1 The sauna heater hasn t been connected 2 There is a prob...

Page 19: ...le is broken 2 The temperature is lower than 0o C 3 The temperature is higher than 115o C 1 Lo C means temperature sensor hasn t connected or the temperature is lower than 0o C check the connection ca...