background image

38 of 59

xxxx xxxx 0000 xxxx = Standalone Mode

xxxx xxxx 0001 xxxx = Primary Mode

xxxx xxxx 0010 xxxx = Secondary Mode

xxxx xxxx 0011 xxxx = Echo Mode

xxxx xxxx 1110 xxxx = Error

xxxx xxxx 1111 xxxx = Data not available

xxxx xx00 xxxx xxxx = Charger Off/Disabled

xxxx xx01 xxxx xxxx = Charger On/Enabled

xxxx xx10 xxxx xxxx = Error

xxxx xx11 xxxx xxxx = Unknown/Unavaiable

xxxx 00xx xxxx xxxx = Eq Pend Off/Disabled

xxxx 01xx xxxx xxxx = Eq Pend On/Enabled

xxxx 10xx xxxx xxxx = Eq Pend Error

xxxx 11xx xxxx xxxx = Unknown/Unavailable

0x017A

0378

Equalisation Time 

remaining

Unsigned 16 bit integer

Range 0 – 65,532 Minutes

Resolution 1 minute

Third Connected Battery Data Registers

0x017B

0379

Operating State

Charge Mode

Charger Enab/Dis

Equalisation Pend

16 bit field

xxxx xxxx xxxx 0000 = Not Charging

xxxx xxxx xxxx 0001 = Bulk

xxxx xxxx xxxx 0010 = Absorption

xxxx xxxx xxxx 0011 = Overcharge

xxxx xxxx xxxx 0100 = Equalise

xxxx xxxx xxxx 0101 = Float

xxxx xxxx xxxx 0110 = No Float

xxxx xxxx xxxx 0111 = Constant VI

xxxx xxxx xxxx 1000 = Disabled

xxxx xxxx xxxx 1001 = Fault

xxxx xxxx xxxx 1110 = Error

xxxx xxxx xxxx 1111 = Data not available

xxxx xxxx 0000 xxxx = Standalone Mode

xxxx xxxx 0001 xxxx = Primary Mode

xxxx xxxx 0010 xxxx = Secondary Mode

xxxx xxxx 0011 xxxx = Echo Mode

xxxx xxxx 1110 xxxx = Error

xxxx xxxx 1111 xxxx = Data not available

xxxx xx00 xxxx xxxx = Charger Off/Disabled

xxxx xx01 xxxx xxxx = Charger On/Enabled

xxxx xx10 xxxx xxxx = Error

xxxx xx11 xxxx xxxx = Unknown/Unavailable

xxxx 00xx xxxx xxxx = Eq Pend Off/Disabled

xxxx 01xx xxxx xxxx = Eq Pend On/Enabled

xxxx 10xx xxxx xxxx = Eq Pend Error

xxxx 11xx xxxx xxxx = Unknown/Unavailable

0x017C

0380

Equalisation Time 

remaining

Unsigned 16 bit integer

Range 0 – 65,532 Minutes

Resolution 1 minute

`

Summary of Contents for NMEA2000 3155

Page 1: ...OCEANIC SYSTEMS NMEA2000 AC MODBUS GATWAY Part Numbers 3155 USER MANUAL Document revision 1 21...

Page 2: ...ers 6 3 2 Modbus Slave Address 7 3 3 Modbus Termination Resistor 7 3 4 NMEA Device Instance 7 3 5 The Device Setup Process 7 4 Front Panel Indicators and Switches 8 5 Fault Finding Troubleshooting 9 5...

Page 3: ...ters 32 7 13 AC Instance 4 Registers 33 7 14 AC Instance 5 Registers 34 7 15 Battery Bank Registers 35 7 16 Battery Charger Instance 0 Registers 37 7 17 Battery Charger Instance 1 Registers 39 7 18 Ba...

Page 4: ...manual Please read and follow the installation and setup instructions carefully to achieve the best results 1 1 PRODUCT FEATURES The 3155 NMEA2000 to Modbus Gateway has the following features RS485 M...

Page 5: ...in an engine room providing the ambient temperature does not exceed 50 C 125 F 3 The location needs to allow for connection to the NMEA2000 interface cable and the RS485 Modbus cable 2 3 MOUNTING THE...

Page 6: ...ce cable on the unit should be connected to a nearby NMEA2000 Tee connector part number 3802 2 The male end of the cable should be inserted into the female Tee connection noting the position of the ke...

Page 7: ...to the default then the DefCm green led will NOT be illuminated The unit can be reset to the default values at any time by pressing the Set DefCom push button when the unit has power on and the ADDR...

Page 8: ...the Modbus Communication line 3 4 NMEA DEVICE INSTANCE NMEA2000 requires a unique Device Instance for each 3155 NMEA2000 to Modbus Gateway on a single network This is settable from device instance 0 t...

Page 9: ...ee 3 1 To 3 3 above The pushbutton is used to capture the default communications protocol from the rotary switch LED Name Description NMRx Receiving an NMEA2000 message NMTx Transmitting an NMEA2000 m...

Page 10: ...MODBUS MESSAGE ERROR LED If the MoFlt led is lit this means that the unit received a Modbus message that it could not carry out This indicates that the communications protocol is probably correct but...

Page 11: ...59 Because it is easy to misunderstand base numbering system it is being shown in this document decimal base 10 values are shown thus 10 decimal value of ten Hexadecimal base 16 values are shown thus...

Page 12: ...individually or collectively Read access to all registers can only be made using the Modbus Function Code 04 Read Input Register command There is NO write access to any input registers except the Swit...

Page 13: ...conds Resolution 1 second 0x0007 0007 Engine Coolant Pressure Unsigned 16 bit integer Range 0 6 553 200 Pa Resolution 1 x 10E 2 Pa 0x0008 0008 Fuel Pressure Unsigned 16 bit integer Range 0 65 532 000...

Page 14: ...x xxxx Reserved x1xx xxxx xxxx xxxx Reserved 1xxx xxxx xxxx xxxx Reserved 0x000B 0011 Percent Engine Load Percent Engine Torque 2x Unsigned 8 bit integers Range 124 Resolution 1 MSB Load LSB Torque 0x...

Page 15: ...r Range 0 4 295x10E 9 seconds Resolution 1 second 0x0018 0024 Engine Coolant Pressure Unsigned 16 bit integer Range 0 6 553 200 Pa Resolution 1 x 10E 2 Pa 0x0019 0025 Fuel Pressure Unsigned 16 bit int...

Page 16: ...ngine Coolant Pressure Unsigned 16 bit integer Range 0 6 553 200 Pa Resolution 1 x 10E 2 Pa 0x0019 0025 Fuel Pressure Unsigned 16 bit integer Range 0 65 532 000 Pa Resolution 1x10E 3 Pa 0x001A 0026 En...

Page 17: ...x Reserved 1xxx xxxx xxxx xxxx Reserved 0x001C 0028 Percent Engine Load Percent Engine Torque 2x Unsigned 8 bit integers Range 124 Resolution 1 MSB Load LSB Torque 0x001D 0029 Engine Speed Unsigned 16...

Page 18: ...2 bit integer Range 0 4 295x10E 9 seconds Resolution 1 second 0x0029 0041 Engine Coolant Pressure Unsigned 16 bit integer Range 0 6 553 200 Pa Resolution 1 x 10E 2 Pa 0x002A 0042 Fuel Pressure Unsigne...

Page 19: ...xxxx Reserved xx1x xxxx xxxx xxxx Reserved x1xx xxxx xxxx xxxx Reserved 1xxx xxxx xxxx xxxx Reserved 0x002C 0045 Percent Engine Load Percent Engine Torque 2x Unsigned 8 bit integers Range 124 Resolut...

Page 20: ...Resolution 0 004 0x003A 0x003B 0058 0059 Tank Capacity 0058 MSW 0059 LSW Unsigned 32 bit integer Range 0 4 296x10E 5 cu m Resolution 1x10E 4 cu m Fuel Tank Instance 3 Registers 0x003C 0060 Fluid Leve...

Page 21: ...0 004 0x0046 0x0047 0070 0071 Tank Capacity 0070 MSW 0071 LSW Unsigned 32 bit integer Range 0 4 296x10E 5 cu m Resolution 1x10E 4 cu m Fuel Tank Instance 7 Registers 0x0048 0072 Fluid Level Signed 16...

Page 22: ...056 Resolution 0 004 0x0052 0x0053 0082 0083 Tank Capacity 0082 MSW 0083 LSW Unsigned 32 bit integer Range 0 4 296x10E 5 cu m Resolution 1x10E 4 cu m Fresh Water Tank Instance 3 Registers 0x0054 0084...

Page 23: ...0 004 0x005E 0x005F 0094 0095 Tank Capacity 0094 MSW 0095 LSW Unsigned 32 bit integer Range 0 4 296x10E 5 cu m Resolution 1x10E 4 cu m Fresh Water Tank Instance 7 Registers 0x0060 0096 Fluid Level Sig...

Page 24: ...31 056 Resolution 0 004 0x006A 0x006B 0106 0107 Tank Capacity 0106 MSW 0107 LSW Unsigned 32 bit integer Range 0 4 296x10E 5 cu m Resolution 1x10E 4 cu m Grey Water Tank Instance 3 Registers 0x006C 010...

Page 25: ...0 004 0x0076 0x0077 0118 0119 Tank Capacity 0118 MSW 0119 LSW Unsigned 32 bit integer Range 0 4 296x10E 5 cu m Resolution 1x10E 4 cu m Grey Water Tank Instance 7 Registers 0x0078 0120 Fluid Level Sign...

Page 26: ...0x0083 0126 0127 Tank Capacity 0126 MSW 0127 LSW Unsigned 32 bit integer Range 0 4 296x10E 5 cu m Resolution 1x10E 4 cu m Oil Tank Instance 3 Registers 0x0084 0128 Fluid Level Signed 16 bit integer R...

Page 27: ...0 004 0x008E 0x008F 0142 0143 Tank Capacity 0142 MSW 0143 LSW Unsigned 32 bit integer Range 0 4 296x10E 5 cu m Resolution 1x10E 4 cu m Oil Tank Instance 7 Registers 0x0090 0144 Fluid Level Signed 16 b...

Page 28: ...09B 0154 0155 Tank Capacity 0154 MSW 0155 LSW Unsigned 32 bit integer Range 0 4 296x10E 5 cu m Resolution 1x10E 4 cu m Black Water Tank Instance 3 Registers 0x009C 0156 Fluid Level Signed 16 bit integ...

Page 29: ...0 004 0x00A6 0x00A7 0166 0167 Tank Capacity 0166 MSW 0167 LSW Unsigned 32 bit integer Range 0 4 296x10E 5 cu m Resolution 1x10E 4 cu m Black Water Tank Instance 7 Registers 0x00A8 0168 Fluid Level Sig...

Page 30: ...ge Line to Line Voltage AC RMS Unsigned 16 bit integer Range 0 64255 Volts Resolution 1 Volt 0x00AD 0173 Average Line to Neutral Voltage Unsigned 16 bit Integer Range 0 64255 Volts Resolution 1 Volt 0...

Page 31: ...e Line to Line Voltage AC RMS Unsigned 16 bit integer Range 0 64255 Volts Resolution 1 Volt 0x00B2 0178 Average Line to Neutral Voltage Unsigned 16 bit Integer Range 0 64255 Volts Resolution 1 Volt 0x...

Page 32: ...ne to Line Voltage AC RMS Unsigned 16 bit integer Range 0 64255 Volts Resolution 1 Volt 0x00B7 0183 Average Line to Neutral Voltage Unsigned 16 bit Integer Range 0 64255 Volts Resolution 1 Volt 0x00B8...

Page 33: ...ne to Line Voltage AC RMS Unsigned 16 bit integer Range 0 64255 Volts Resolution 1 Volt 0x00BC 0188 Average Line to Neutral Voltage Unsigned 16 bit Integer Range 0 64255 Volts Resolution 1 Volt 0x00BD...

Page 34: ...ne to Line Voltage AC RMS Unsigned 16 bit integer Range 0 64255 Volts Resolution 1 Volt 0x00C1 0193 Average Line to Neutral Voltage Unsigned 16 bit Integer Range 0 64255 Volts Resolution 1 Volt 0x00C2...

Page 35: ...igned 16 bit integer Range 0 64255 Volts Resolution 1 Volt 0x00C6 0198 Average Line to Neutral Voltage Unsigned 16 bit Integer Range 0 64255 Volts Resolution 1 Volt 0x00C7 0199 Frequency Unsigned 16 b...

Page 36: ...Amps Resolution 1x10E 1 Amps 0x0164 0356 Battery Case Temp Unsigned 16 bit integer Range 0 655 32 K Resolution 1x10E 2 K Battery Bank Instance 2 Registers 0x0165 0357 Battery Voltage Signed 16 bit int...

Page 37: ...Range 3 276 4 Amps Resolution 1x10E 1 Amps 0x0170 0368 Battery Case Temp Unsigned 16 bit integer Range 0 655 32 K Resolution 1x10E 2 K Battery Bank Instance 6 Registers 0x0171 0369 Battery Voltage Sig...

Page 38: ...xxx Data not available xxxx xx00 xxxx xxxx Charger Off Disabled xxxx xx01 xxxx xxxx Charger On Enabled xxxx xx10 xxxx xxxx Error xxxx xx11 xxxx xxxx Unknown Unavailable xxxx 00xx xxxx xxxx Eq Pend Off...

Page 39: ...xxxx 0000 Not Charging xxxx xxxx xxxx 0001 Bulk xxxx xxxx xxxx 0010 Absorption xxxx xxxx xxxx 0011 Overcharge xxxx xxxx xxxx 0100 Equalise xxxx xxxx xxxx 0101 Float xxxx xxxx xxxx 0110 No Float xxxx x...

Page 40: ...xxx Data not available xxxx xx00 xxxx xxxx Charger Off Disabled xxxx xx01 xxxx xxxx Charger On Enabled xxxx xx10 xxxx xxxx Error xxxx xx11 xxxx xxxx Unknown Unavailable xxxx 00xx xxxx xxxx Eq Pend Off...

Page 41: ...xxxx 0000 Not Charging xxxx xxxx xxxx 0001 Bulk xxxx xxxx xxxx 0010 Absorption xxxx xxxx xxxx 0011 Overcharge xxxx xxxx xxxx 0100 Equalise xxxx xxxx xxxx 0101 Float xxxx xxxx xxxx 0110 No Float xxxx x...

Page 42: ...xxx Data not available xxxx xx00 xxxx xxxx Charger Off Disabled xxxx xx01 xxxx xxxx Charger On Enabled xxxx xx10 xxxx xxxx Error xxxx xx11 xxxx xxxx Unknown Unavailable xxxx 00xx xxxx xxxx Eq Pend Off...

Page 43: ...xxxx 0000 Not Charging xxxx xxxx xxxx 0001 Bulk xxxx xxxx xxxx 0010 Absorption xxxx xxxx xxxx 0011 Overcharge xxxx xxxx xxxx 0100 Equalise xxxx xxxx xxxx 0101 Float xxxx xxxx xxxx 0110 No Float xxxx x...

Page 44: ...xxx Data not available xxxx xx00 xxxx xxxx Charger Off Disabled xxxx xx01 xxxx xxxx Charger On Enabled xxxx xx10 xxxx xxxx Error xxxx xx11 xxxx xxxx Unknown Unavailable xxxx 00xx xxxx xxxx Eq Pend Off...

Page 45: ...xxxx 0000 Not Charging xxxx xxxx xxxx 0001 Bulk xxxx xxxx xxxx 0010 Absorption xxxx xxxx xxxx 0011 Overcharge xxxx xxxx xxxx 0100 Equalise xxxx xxxx xxxx 0101 Float xxxx xxxx xxxx 0110 No Float xxxx x...

Page 46: ...ith the following values which vary whether the switch is being read or set When controlling or reading the switchves using the Holding Registers then these values MUST be used by the Modbus Master de...

Page 47: ...e above 0x0191 0401 Switches 17 24 16 bit field SSxx xxxx xxxx xxxx Switch 17 bits xxSS xxxx xxxx xxxx Switch 18 bits xxxx SSxx xxxx xxxx Switch 19 bits xxxx xxSS xxxx xxxx Switch 20 bits xxxx xxxx SS...

Page 48: ...able above 0x0196 0406 Switches 25 28 16 bit field xxxx xxxx SSxx xxxx Switch 25 bits xxxx xxxx xxSS xxxx Switch 26 bits xxxx xxxx xxxx SSxx Switch 27 bits xxxx xxxx xxxx xxSS Switch 28 bits Values as...

Page 49: ...xxxx Switch 2 bits xxxx SSxx xxxx xxxx Switch 3 bits xxxx xxSS xxxx xxxx Switch 4 bits xxxx xxxx SSxx xxxx Switch 5 bits xxxx xxxx xxSS xxxx Switch 6 bits xxxx xxxx xxxx SSxx Switch 7 bits xxxx xxxx x...

Page 50: ...16 bit field SSxx xxxx xxxx xxxx Switch 9 bits xxSS xxxx xxxx xxxx Switch 10 bits xxxx SSxx xxxx xxxx Switch 11 bits xxxx xxSS xxxx xxxx Switch 12 bits xxxx xxxx SSxx xxxx Switch 13 bits xxxx xxxx xxS...

Page 51: ...per bit value table above 0x01A5 0421 Switches 17 24 16 bit field SSxx xxxx xxxx xxxx Switch 17 bits xxSS xxxx xxxx xxxx Switch 18 bits xxxx SSxx xxxx xxxx Switch 19 bits xxxx xxSS xxxx xxxx Switch 20...

Page 52: ...able above 0x01AA 0426 Switches 25 28 16 bit field xxxx xxxx SSxx xxxx Switch 25 bits xxxx xxxx xxSS xxxx Switch 26 bits xxxx xxxx xxxx SSxx Switch 27 bits xxxx xxxx xxxx xxSS Switch 28 bits Values as...

Page 53: ...xSS xxxx xxxx Switch 20 bits xxxx xxxx SSxx xxxx Switch 21 bits xxxx xxxx xxSS xxxx Switch 22 bits xxxx xxxx xxxx SSxx Switch 23 bits xxxx xxxx xxxx xxSS Switch 24 bits Values as per bit value table a...

Page 54: ...osure or seals Ensure that the unit is mounted securely and cannot be moved relative to the mounting surface If the unit is loose tighten the mounting screws Check the security of the cables connected...

Page 55: ...SPECIFICATION 9 Parameter Comment NMEA2000 Level B Maritime Nav and RadioComm Equipment IEC60945 CE and FCC Electromagnetic Compatibility Source Max No PGN No PGN Name Engines 3 127488 Engine Paramete...

Page 56: ...t 160gm Parameter Value IEC 60954 Classification Protected Degree of Protection IP40 Operating Temperature 25 C to 50 C Storage Temperature 40 C to 70 C Relative Humidity 93 RH 40 per IEC60945 8 2 Vib...

Page 57: ...ive New Milton Hampshire BH25 6RH United Kingdom Tel 44 0 1425 610022 Fax 44 0 1425 614794 Email sales osukl com Web www osukl com Copyright 2017 Oceanic Systems UK Ltd All rights reserved Our policy...

Page 58: ...DAMAGES DAMAGES FOR LOSS OF USE LOSS OF ANTICIPATED PROFITS OR SAVINGS OR ANY OTHER LOSS INCURRED BECAUSE OF INTERRUPTION OF SERVICE IN NO EVENT SHALL OCEANIC SYSTEMS AGGREGATE LIABILITY EXCEED THE PU...

Page 59: ...58 of 59...

Page 60: ...59 of 59 OCEANIC SYSTEMS PRODUCT MAP 10...