11
DELUXE ELECTRONIC CONTROLLER
The 2OACH1211 controller is equipped with many features for a more precise level of
comfort and operation. Additionally, the controller can be removed from the unit
and installed for remote operation (additional parts are required).
POWER
button
OCEANAIRE DELUXE ELECTRONIC CONTROLLER
When power is connected, the controller will display “888” momentarily, and will
then disappear. Press the
POWER
button, then press the
TEMP SELECT
button
until the
SET POINT
is displayed. Adjust the
SET POINT
to the desired temperature,
and the unit will heat/cool as programmed.
The systems controls temperature /- 2°
POWER
Turns the unit on/off when power is supplied
MODE
Select the mode of operation from
AUTO...COOL….HEAT….MOISTURE CONTROL
.
AUTO
The controller will heat or cool as required.
HEAT or COOL
will
display accordingly. A 4° differential is needed to change between
cooling and heating modes.
COOL
The system will operate in
cooling mode, only
.
HEAT
The system will operate in
heating mode, only.
MOISTURE CONTROL
The system operates in the cooling mode to reduce
humidity within the conditioned space. Every 4 hours, the fan is started, circulating
the air, and the air temperature is recorded by the controller. The cooling cycle is
started for one hour, or until the room temperature drops 2°, which ever comes first.
This cycle repeats every four hours.