background image

 

CARE

 

OF

 

THE

 

WOOD

 

PANEL

 

AND

 

DUST

 

COVER

 

1.

 

Care

 

of

 

the

 

unit

 

is

 

the

 

same

 

as

 

any

 

piece

 

of

 

the

 

furniture.

 

2.

 

When

 

the

 

dust

 

cover

 

is

 

dusty,

 

you

 

may

 

wipe

 

it

 

using

 

soft,

 

non

abrasive

 

dust

 

cloth.

 

3.

 

If

 

the

 

wood

 

panel

 

becomes

 

smudged

 

with

 

fingerprints,

 

you

 

may

 

use

 

any

 

good

 

quality

 

commercial

 

dusting

 

and

 

polishing

 

spray

 

cleaner.

 

4.

 

We

 

recommend

 

spraying

 

the

 

cleaner

 

on

 

the

 

cloth,

 

not

 

directly

 

on

 

the

 

wooden

 

panel.

 

 

CARE

 

AND

 

MAINTENANCE

 

To

 

replace

 

the

 

cartridge

 

from

 

the

 

tone

 

arm,

 

please

 

follow

 

the

 

procedure

 

below.

 

1.

 

Gently

 

lift

 

off

 

the

 

tone

 

arm

 

from

 

the

 

tone

 

arm

 

lock.

 

2.

 

By

 

using

 

your

 

left

 

hand

 

to

 

hold

 

the

 

tone

 

arm

 

and

 

using

 

your

 

right

 

hand

 

to

 

hold

 

the

 

rear

 

portion

 

of

 

the

 

cartridge.

  

Then

 

push

 

the

 

cartridge

 

backwards

 

and

 

downwards

 

according

 

to

 

the

 

direction

 

as

 

shown

 

to

 

the

 

left

 

to

 

separate

 

the

 

cartridge

 

from

 

the

 

tone

 

arm.

 

3.

 

Using

 

either

 

a

 

tweezer

 

or

 

your

 

fingers,

 

carefully

 

unplug

 

the

 

terminals

 

to

 

the

 

new

 

cartridge.

 

4.

 

Carefully

 

connect

 

the

 

terminals

 

to

 

the

 

new

 

cartridge

 

(not

 

included).

 

5.

 

To

 

re

install

 

the

 

new

 

cartridge

 

to

 

the

 

tone

 

arm.

  

First

 

please

 

lock

 

the

 

front

 

end

 

of

 

the

 

new

 

cartridge

 

on

 

the

 

hook

 

of

 

the

 

tone

 

arm.

 

6.

 

Press

 

the

 

rear

 

s=ide

 

of

 

the

 

new

 

cartridge

 

upwards

 

to

 

lock

 

it

 

on

 

the

 

tone

 

arm.

 

Summary of Contents for ty-lp200

Page 1: ...TY LP200 USB MP3 DIRECT RECORDING TURNTABLE SYSTEM Instruction Manual ...

Page 2: ...he box Main Unit Power Adapter Instruction Manual 45 RPM Adapter READ SAFETY INSTRUCTION BOOK BEFORE USING THE PRODUCT FUNCTION KEY PANEL LED INDICATOR 1 USB 2 PHONO 3 BLUETOOTH 4 AUX 5 REC KEY 6 FUNCTION 7 I VR Volume 8 I VR Volume 9 PLAY PAIR 10 STOP REC 11 USB SOCKET ...

Page 3: ...PEAKER OUT 2 LINE IN 3LINE OUT 4DC IN 15V 1600mA 5POWERON OFF TURNTABLE PANEL 1 TURNTABLE 2 FUNCTIONKEY PANEL 3TRANSIT SCREW CROSSING 4 LIFT LEVER 5 SPEED SELECTOR 33 45 78 RPM 6 TONE ARM LOCK 7 TONE ARM WITH STYLUS ...

Page 4: ... turn the on the unit 3 When you have finished using the system press Power ON OFF button again to turn off the unit NOTE When select a certain function but without further instruction or signal to the unit during 30 minutes the unit will automatically turn off LINE IN OPERATION 1 This unit provides aLINE INjack for connecting external audio devices like MP3 players CD players and older non dock a...

Page 5: ...VER gently backward to you the tone arm gently lifter onto the record The song will stop playing 6 Press the I VR Volume I VR Volume to set the volume as desired 7 Press Power ON OFF switch to turn off the system when you are done 8 During record playing please open the dust cover PHONOGRAPH RECORDING OPERATION 1 Place a phone record on the turntable 2 Plug USB stick into USB socket Press PHONO RE...

Page 6: ...the BLUETOOTH function and the light will be flash on 2 Set up the Bluetooth playback device so it searches for other Bluetooth devices 3 Select the entry TY LP200 from the list of found devices on your Bluetooth playback device If the pairing is successful you will hear a signal with Di sound 4 Enjoy your music from your playback device NOTE 1 The next time you turn on the device it will automati...

Page 7: ...it separates from the cartridge housing 3 Completely remove the red stylus holder with worn stylus and discard it 4 Place the new red stylus holder with stylus under the cartridge housing First press upward on the back side of the stylus holder and then press up on the front edge of the stylus holder until it snaps into place on the cartridge housing 5 Through the speakers of external playback dev...

Page 8: ... below 1 Gently lift off the tone arm from the tone arm lock 2 By using your left hand to hold the tone arm and using your right hand to hold the rear portion of the cartridge Then push the cartridge backwards and downwards according to the direction as shown to the left to separate the cartridge from the tone arm 3 Using either a tweezer or your fingers carefully unplug the terminals to the new c...

Page 9: ...comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with theinstructions may cause harmful interference to radio communications Howe...

Page 10: ... evaluated to meet general RF exposure requirement The device can be used in Portable exposure condition without restriction This device complies with Industry Canada s licence exempt RSSs Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accept any interference including interference that may cause undesired operation of the devic...

Reviews: