6 - TROUBLESHOOTING

Problem

Probable cause

What to do  

The surface 

unit does not 

turn on

1. 

Damaged  power  supply 

cord or wrong voltage 

settings

1.  Contact OCEAN REEF 

customer service.

The 

underwater 

unit does not 

receive

1.  Surface unit power 

turned off

2.  Cables not properly 

connected 

3.  Low volume

4.  Flooded underwater unit

1.  Switch on the surface unit

2. 

Check cables connection

3. 

Check mixer settings

4.  Return to surface, rinse in fresh 

water and send to OCEAN 

REEF service center

Surface is not 

receiving 

1.  Volume too low

2. 

Power turned off

3.  Flooded microphone on 

underwater unit

1. 

Check mixer settings

2.  Turn on the surface unit

3.  Return to surface, rinse in fresh 

water, replace mic

No trasmission 

only in half 

duplex mode 

from diver

1. 

PTT button not being 

operated by diver

2. 

PTT button damaged/

not working

1. 

Instruct diver to speak while 

pressing PTT.

2.  Return to surface, rinse in fresh 

water, replace mic.

Replacing the Mic (D-Mic cod. 008598)

Remove the MIC assembly from the mask, unscrew few threads of the two little side screws 

and pull off the Mic. Replace with the new one being careful not to overtighten the little 

screws to avoid damages to the contacts and to mount the microphone in the same direction.

Summary of Contents for AQUARIST

Page 1: ...AQUARIST OWNER S MANUAL WARNING MAKE SURE YOU HAVE SELECTED THE CORRECT POWER SOURCE VOLTAGE ON THE BACK OF THE UNIT BEFORE POWERING ON 120V 240V...

Page 2: ...S RESPONSIBILITIES 3 TIPS REMINDERS FOR USE 4 FEATURES AND COMPONENTS PACKAGE CONTENTS 4 1 SURFACE UNIT 4 2 PROFESSIONAL SURFACE DIVER CABLE 4 3 UNDERWATER UNIT 2 0 5 SET UP THE UNIT 6 TROUBLESHOOTING...

Page 3: ...not accept liabilities for any damage caused by Insufficient incorrect and improper maintenance failing to comply with the manual s recommendations Absence of periodic tests and checks Incorrect and...

Page 4: ...OCEAN REEF reserves the right to modify any products processes and manufacturing techniques at any time It is the technicians responsibility to acquire the latest information and parts from OCEAN REEF...

Page 5: ...e When not in use or at the end of each use make sure that the surface unit has been turned off Make sure there is no dirt debris or water in any part of the unit especially in the rubber 6 pin connec...

Page 6: ...ide audience extending the capability of an integrated loudspeaker of a typical surface unit and the audience and viceversa for the audience to communicate back to the diver Moreover the volume of the...

Page 7: ...arious standard lengths or length can be customized to accommodate customer s need Max 200m 600ft see pag 9 3 Alpha Pro 2 0 uw unit see pag 10 The surface unit receives the input audio of an underwate...

Page 8: ...N LED 5 Half Full Duplex switch Half Duplex only for diver see pag 10 6 Microphone mixer PA system in 7 Diver audio out port to mixer 8 Port for diver audio in uw unit 6 pin cable to surface DIN conne...

Page 9: ...3169 It is fundamental to pay attention that the cable does not get stuck If needed it is possible to keep the cable slightly buoyant by attaching a small buoy or floating device to the cable a few fe...

Page 10: ...roof connector Weight 0 3 Kg 0 66 lbs The connector between the cable and the underwater unit can be disconnected and connected again underwater When used with Aquarist the UW Alpha Pro 2 0 unit can o...

Page 11: ...Y 5 SET UP THE UNIT AQUARIUM IDM scuba diver announcer With Alpha Pro UW unit 2 0 Aquarist Professional Audio Cable 110 220 AC power supply X L R C o n n e c t i o n s Audio Mixer Microphone Etc PA sy...

Page 12: ...ceiving 1 Volume too low 2 Power turned off 3 Flooded microphone on underwater unit 1 Check mixer settings 2 Turn on the surface unit 3 Return to surface rinse in fresh water replace mic No trasmissio...

Page 13: ...The product must be stored completely dry Do not use solvents such as diluents to clean the unit They can cause irreparable damage Only use neutral detergents Do not expose the unit to direct sunlight...

Page 14: ...as purchased Damage caused by fire earthquake floods lightning or other natural disasters The warranty card is not produced Your name the date of purchase and the distributor s name do not appear on t...

Page 15: ...Aquarist rel 1 0 15 UNDERWATERNATURALLY NOTES...

Page 16: ...E mail operator oceanreefgroup com MESTEL Safety s r l Via Arvigo 2 16010 Genova Italia Phone 39 010 7082011 E mail infoitaly oceanreefgroup com diving oceanreefgroup com oceanreefgroup com ACCESSORY...

Reviews: