LS-1 Series Tungsten Halogen Light Sources 

LS-1 Series Tungsten Halogen Light Sources    

2 

Using the LS-1 

 

Warning 

Do NOT insert plastic or flammable materials into the 3 mm filter slot on the top of the LS-1. These 
materials could melt or ignite due to the extreme heat generated by the light source. 

The light source becomes extremely hot during operation and does not feature a cooling fan.  Handle 
with extreme care during operation. 

Connecting the LS-1 

Follow the instructions below to connect your LS-1 light source: 

1.  Plug the 12 VDC power supply into a standard wall outlet. 

2.  Plug the 12 V output end of the power supply into the back of the LS-1. 

3.  Connect a fiber to the SMA 905 connector on the LS-1. 

4.  Switch the lamp on using the silver On/Off switch on the rear of the LS-1 and allow the lamp to warm up 

for approximately 30 minutes. 

The LS-1 is now ready to be connected to your sampling system. 

Installing the Blue Filter or Teflon Discs in the LS-1 

The BG-34 filter and Teflon disc can be permanently installed into the LS-1 to further optimize your experiment. 
The BG-34 filter amplifies the blue region in relation to the other regions in the spectrum, while the Teflon discs 
diffuse the light emitted from the LS-1. A BG-34 transmission graph can be found at the end of this manual. 

Follow the instructions below to install the BG-34 blue filter or Teflon discs into the LS-1: 

Note:  This procedure involves opening the LS-1 light source. Before opening, ensure that the lamp has been off 

long enough to allow the unit to cool and disconnect the power supply from the LS-1. 

1.  Remove the two black hex bolts (located on either side of the silver On/Off switch) using a 3/32 Allen 

wrench (not included).  Keep these bolts nearby. 

2.  Turn the LS-1 over and use the 0.050” Allen wrench included with the LS-1 to loosen the small silver 

screw located directly in the middle of the front portion of the lamp, directly between the heat fins of the 
LS-1.  

3.  Separate the two halves of the LS-1 by gently pulling them apart.  Ensure that you the wires of the LS-1 

are not caught and that the unit separates easily. 

4.  Insert the BG-34 filter or Teflon disk you wish to install into the ½” counter bore on the inside of the front 

half of the LS-1 (where the silver lamp tube resides when the lamp is assembled). Ensure that the disk 
lays flush against the bottom of the ½” counter bore. 
 
When inserting the T-shaped Teflon plug, insert the narrow end first. 

5.  Replace the silver lamp tube, ensuring that it is fully inserted into the ½” counter bore. Verify that the 

black wire that connects to the bulb is still connected. 

6.  Hold the silver lamp tube in place and re-insert the small silver screw that you loosened in Step 2. This 

fastens the silver lamp tube in place. 

7.  Re-attach the two sides of the LS-1, ensuring that the lamp is fully connected. 

Note:  If you cannot fully reconnect the LS-1 due to the installed filter, you may need to gently move the 

black capacitor in the rear half of the LS-1 out of the way until the halves properly connect. 

(Continued) 

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for LS-1 Series

Page 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Page 2: ...Tungsten Halogen Light Source Standard LS 1 light sources come with a 900 hour 3100 K bulb However the LS 1 LL long life is identical to the LS 1 with the exception of its 10 000 hour 2800 K bulb Part...

Page 3: ...g ensure that the lamp has been off long enough to allow the unit to cool and disconnect the power supply from the LS 1 1 Remove the two black hex bolts located on either side of the silver On Off swi...

Page 4: ...Use the included Allen wrench to loosen the setscrew on the bottom of the lamp You do not need to remove the setscrew This screw holds the bulb in place inside the LS 1 4 Remove the two black hex bol...

Page 5: ...pectrometer saturation is an issue From smallest to largest the three Teflon discs attenuate the light by approximately 50 75 and 99 respectively The BG 34 blue filter is a 12 7 mm filter that you can...

Page 6: ...Use a 3 16 nut driver or a small adjustable wrench to remove the four rack post nuts from the top component of the rack system see diagram above Keep the four rack post nuts in a safe place 2 Lift the...

Page 7: ...f the R LS 1 card 4 Use the Allen wrench included with the R LS 1 to loosen the small silver screw It is not necessary to remove this screw completely 5 Slide the silver lamp tube out of the blue anod...

Page 8: ...lips screws on the bottom of the R LS 1 These screws hold the blue anodized bulb housing in place on the R LS 1 card 5 Slide the R LS 1 in place on the card until the recessed silver Allen screw is vi...

Page 9: ...ers contained on an S2000 spectrometer However H1 is not used by the R LS 1 It is only required when the R LS 1 is rack mounted between spectrometers The light on the R LS 1 can be toggled on and off...

Page 10: ...es Comparison of typical LS 1 Scope mode signal with and without BG 34 filter Specifications LS 1 and R LS 1 LS 1 R LS 1 Spectral range 360 2000 nm If used with an Ocean Optics spectrometer the practi...

Page 11: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Reviews: