              SAFETY 

PRECAUTIONS 

 

 

 

1.  To prevent fire or shock hazard, do not expose this equipment to high  

humidity and/or dust. Do not use in an unprotected outdoor installation 
nor any area classified as overly damp or wet. 

2.  The temperature for installation should be kept between 32°F to 140°F  

(0°C to 60°C). Avoid direct sunlight exposure or extreme changes of  
temperature over a short period of time. 

3.  Do not disassemble the unit or place it on an unstable base. 

4.  Do not drop the unit and avoid heavy impact. 

5.  This unit should not be permanently installed unless proper ventilation is 

provided. Any enclosure openings must not be blocked or covered as they 
protect the unit from overheating. 

6.  Before cleaning, turn off the power and unplug the unit from all connec-

tions. Use a damp cloth. Do not use liquid cleaners nor aerosol cleaners. 

7.  Do not overload outlets and extension cords as this may result in a risk of 

fire or electric shock. 

8.  Enclosure entry is dangerous. Never push objects of any kind, including 

liquids, into this unit through openings as they may touch dangerous  
voltage points or short-out parts that could result in a fire or electric shock. 

9.  Do not attempt to open or service this unit yourself as opening or removing 

covers may expose you to dangerous voltage and other hazards. 

10. 

There are no user-serviceable parts inside the unit. If the unit requires  
service contact your authorized dealer, or an authorized repair service 
company.

 

Summary of Contents for OMX-3GSDI-CAT5

Page 1: ...USER MANUAL OMX 3GSDI CAT5 3GSDI Extender Over IP Via Single UTP Cat5e 6e 7 Ocean Matrix 812 Kings Highway Saugerties NY 12477 www oceanmatrix com ...

Page 2: ...2A power adapters One IR blaster extension cable connects to transmitter One IR receiver extension cable connects to receiver Specifications Supported Resolutions SD SDI 480i 60Hz 576i 50Hz HD SDI 720p 50 60Hz 1080i 50 60Hz 1080p 24 25 30Hz 3GSDI 1080p 50 60Hz Network Cable UTP Cat5e 6e 7 Transmission Range 1080p resolution up to 394 ft 120m over Cat6 IR Remote Control Supports 20 60kHz standard I...

Page 3: ...roper connections during installation 2 Do not hot plug swap when in operation 3 Use 5VDC power supply only IR User Guide 1 Plug the IR blaster extension cable into the IR out port of the Trans mitter TX 2 Plug the the IR receiver extension cable into the IR IN port of the Receiver RX 3 Place the emitter of the IR blaster as close as possible to the IR receiver of the signal source device 4 Direct...

Page 4: ...ower Input 5VDC 7 RX Reset Button 8 RX Signal Input 11 TX RX Power Status Indicator 12 TX RX Data Transmission Indicator 13 TX RX Network Connection Indicator 1 TX Power Input 5VDC 2 TX Reset Button 3 TX Signal Output 10 RXSDI Signal Output 9 RX IR Extension Cable Port 4 TX IR Blaster Extension Cable Port 5 TX SDI Signal Input ...

Page 5: ... Check signal input of the TX Connect the signal source directly to the display device to ensure there is a signal output Change the signal source if necessary Degraded video signal Check cable lengths between the TX to the switch the switch to RX Ensure the connection between each level is within required ranges Press the RESET button on the TX RX front panel Ensure all connections are secure Oce...

Page 6: ...y enclosure openings must not be blocked or covered as they protect the unit from overheating 6 Before cleaning turn off the power and unplug the unit from all connec tions Use a damp cloth Do not use liquid cleaners nor aerosol cleaners 7 Do not overload outlets and extension cords as this may result in a risk of fire or electric shock 8 Enclosure entry is dangerous Never push objects of any kind...