CONTROL  PADS  ON  THE  DEHUMIDIFIER

Other Features 

Bucket Full Light

Glows when the bucket  is ready to be emptied.

When frost builds up on the evaporator coils, the 

compressor will cycle off and the fan will continue 

to run until the frost disappears.

Auto Defrost

Wait 3 minutes before resuming operation

After the unit has stopped, it cannot be

 restarted

immediately in the first 3 minutes. 

This is to prevent

damage to the unit. 

Operation will automatically

start after 3 minutes.

Setting the Timer

While the unit is on, press the TIMER button

to initiate the AUTO STOP program, indicated

by the TIMER OFF light. Press again to initiate 

the AUTO START program, indicated by the 

 

TIMER ON light.
While the unit is off, press the TIMER button

to initiate the AUTO START program, indicated

by the TIMER ON light.

Press or hold the UP or DOWN button to change

the Auto Timer by half hour increments up to 24

hours. The display will show the time remaining

until start/stop.

 

The selected time will show for 5 seconds and

then the system will automatically revert back to 

displaying the previous humidity setting.

 

Turning the unit ON or OFF at any time or adjusting

the Timer setting to 0.0 will cancel the Timer.

 

When the AUTO START & STOP times are set,

the TIMER ON/OFF indicator lights up to show

that the Timer is on.

Check filter feature

The system counts every time the fan motor operates. 

when the accumulated operation time achieves 250 hours

or more, the check filter light will flash to remind that the

the filter needs cleaning. After finishing cleaning and putting

back the air filter, be sure to press the filter button to reset

the clean filter counter and turn off the indicator light.

Display

Shows the set humidity level from 35% to 85% or auto 

start/stop time (0~24) while setting, then shows the actual

±

(

RH(Relative Humidity) to 90%RH(Relative Humidity).

Error Codes and Protection Code:

AS

- Humidity sensor error: Unplug the unit and plug it back

       in. If error repeats, call for service.

ES

- Temperature sensor error: Unplug the unit and plug it 

       back in. If error repeats, call for service.

P2

- Bucket is full: Empty the bucket.

Auto Shut Off

The 

 shuts off  when the bucket  is 

full, or when the bucket is removed or not placed 

in the proper position. When the set humidity is

reached, the unit will be shut off automatically. 

For some models, the fan motor will continue 

operating.

dehumidifier

Auto-Restart

If the unit shuts off unexpectedly due to a 

power outage

when the power resumes.

EC

- Unit 

malfunction

: Please make sure 

that

 the 

       

       

       

       

environment temperature is 

within the standard operating 

temperature in the manual. If the current temperature is

working, call for service.

within the standard operating temperature and it still isn’t

6

Timer 

button

Press to initiate the Auto start and Auto stop feature, 

in conjunction with the       and        buttons.

E3

- Unit malfunction: Unplug the unit and plug it back in. If 

      error repeats, call for service.

Eb

- Bucket is 

not present or not in right position: Remove 

       the bucket and put back in the right position.

it will restart with the previous function setting automatically

%

0

3

 f

o

 

e

g

n

a

a

 

ni

 l

e

v

el

 y

ti

di

m

u

h

 

m

o

o

)

y

c

a

r

u

c

c

a

 

%

5

Summary of Contents for OBZ-50DHPN

Page 1: ...OBZ 50DHPN DEHUMIDIFIER INSTRUCTION MANUAL Service Number 1 866 277 7878 www oceanbreezecomfort com Before operating this product please read the instructions carefully and save this manual for futur...

Page 2: ...ERATING THE UNIT Before operating the unit 7 Removing the collected water 8 CARE AND MAINTENANCE 10 TROUBLESHOOTING TIPS Troubleshooting 11 DEHUMIDIFIER CONTROLS Control panel 4 Other features 5 DESCR...

Page 3: ...r others the following instructions must be followed Improper operation due to not following the instructions may cause harm or damage Do not repeatedly turn the power on and off It may cause water to...

Page 4: ...This will cause the corrosion to the unit due to chemicals evaporated in the air sensitive to always unplug the unit before installing and or servicing grilles manufacturers...

Page 5: ...removal of the Turbo Turbo for collected water button button button hours normal DEHUMIDIFIER CONTROLS Fig 1 3 Auto defrost operation on indicator light High fan indicator light Filter Pump Fan Timer...

Page 6: ...to remind that the the filter needs cleaning After finishing cleaning and putting back the air filter be sure to press the filter button to reset the clean filter counter and turn off the indicator li...

Page 7: ...DESCRIPTION OF PARTS Identifying the parts...

Page 8: ...minutes to restart the unit Plug the unit into an electric outlet with a grounded connection 7 15 8 in or 7 9 in 7 9 in 7 9 in 7 9 in level Please be careful to move the machine to avoid the unit fro...

Page 9: ...ou must reinstall the pump properly to the unit before replacing the bucket back into the unit see Fig 8 After you remove the bucket if there is some water in the unit you must dry it out When the uni...

Page 10: ...d fan speed on the unit for pump draining to start Drain hose subassembly Continuous drain hose Plastic cover Fig 11 Pump drain hose Pump drain hose outlet Fig 12 NOTE The pump operation on light flas...

Page 11: ...or on some models remove the bucket then pull filter Store the unit upright in a dry well ventilated area...

Page 12: ...er openings are securely closed O O Room temperature is too low below 41 F 5 C There is a kerosene heater or something giving off water vapor in the room The unit makes a loud noise when operating The...

Reviews: