5
DEHUMIDIFIER CONTROL PANEL
Other features
Bucket Full Light
Glows when the bucket is ready to be
emptied, or when the bucket is removed
or not placed in the proper position.
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue
to run until the frost disappears.
Auto Defrost
Wait 3 minutes before resuming operation
After the unit has stopped, it cannot be restarted
immediately. This is to protect the unit from mal-
function. Operation will automatically start after
3 minutes.
Check filter feature
The system starts to count the time once the fan
motor operates. The check filter feature will be lit
when the accumulated operation time achieves
250 hours or more. The Reset light(Clean filter
indicator light) flashes until the filter is cleaned.
Press the Filter button to reset and stop the blinking filter
and Reset light(Clean filter indicator light).
Display
Shows the set % humidity level from 35% to 85% or auto
start/stop time (0~24) while setting, then shows the actual
( 5% accuracy) room % humidity level in a range of 30%
RH(Relative Humidity) to 90%RH(Relative Humidity).
Error Codes and Protection Code:
AS
- Humidity sensor error--Unplug the unit and plug it back
in. If error repeats, call for service.
ES
- Temperature sensor error-- Unplug the unit and plug it
back in. If error repeats, call for service.
P2
- Bucket is full or bucket is not in right position-- Empty
the bucket and replace it in the right position.
P1
- Unit has frost build up-- Allow the unit to run on
AUTO DEFROST mode.
Auto Shut Off
Auto-Restart
If the unit shuts off unexpectedly due to a power outage,
it will restart automatically with the previous function setting
when the power resumes.
EC
- Unit malfunction--Please make sure whether the
environment
temperature is suitable for the stated
temperature in the manual or not.
If not,please operate
the unit under the stated temperature.
If the environment
temperature is normal for the stated temperature, please
call for service.
Setting the
Timer
When the unit is on, first press the TIMER
button, the TIMER OFF indicator light
illuminates. It indicates the
Auto
Stop
program is initiated. Press it again for
the
TIMER
ON
indicator
light
to
come
on
to
indicate the Auto Start is initiated.
When the unit is off,
first
press the
Timer
button for the
TIMER ON indicator
light
to come on to
indicate the
Auto
Start
program. Press again to stop the Timer
and initiate Auto Stop.
Press or hold the UP
or DOWN buttons to
change the
Auto
timer by half hour incre-
ments, up to 10 hours, then at 1 hour
i
w
n
i
c
ll
r
c
e
o
m
u
e
n
n
t
t
d
s
o
u
w
p t
n t
o
h
2
e
4
t
ho
ime
u
r
rs
ema
. Th
i
e
n
c
in
o
g
n
u
tr
n
o
t
l
il
the start/stop time.
The selected time
will register in 5 seconds
and the system
will automatically revert
back to display the previous
humidity setting.
W
se
h
t,
e
w
n t
it
h
h
e
in
A
t
u
h
t
e
o
s
s
a
t
m
ar
e
t
p
&
r
A
o
u
g
t
r
o
am
st
s
op
eq
ti
u
m
e
e
n
s
c
a
e
r
,
e
TIMER ON OFF indicator
lights both turn on
to show that the TIMER ON and OFF program
is active.
Turning the unit ON or OFF at any time or
adjusting the timer setting to 0.0 will cancel
the
Auto
Start/Stop function.
When LED
display
window displays the
c
a
o
ls
d
o
e
b
P2,
e ca
th
n
e
c
A
ell
u
ed.
to Start/Stop function will
6
PARTS IDENTIFICATION
Power Cord and plug
Drain hose outlet
Band(Used only when
storing the unit.)
Front
Rear
Air outlet grille
Caster wheels
Parts identification
Fig.2
Fig.3
Air filter (behind the grille)
Control panel
Air intake grille
Water bucket
1
2
3
4
5
1
2
3
4
NOTE:
All pictures in the manual are for
explanation purposes only.The actual
design of your unit may be slightly different,
but the operations and
functions are the same.
5
1
2
3
4
Accessories:
Drain hose(1pc)
Screw(2pc)
Adapter A(1pc)
6
6
Handle (both sides)
1
2
3
Dehumidifier Capacity
Water Tank Volume
30 / 40 pints
6.3 pints
60 pints
12.7 pints
The dehumidifier shuts off after 30 seconds when
the bucket is full, or when the bucket is removed
or not placed in the proper position. When the set
humidity is reached, the unit will shut off auto-
matically. For some models,the fan motor will
continue operating.