GENERAL INFORMATION

 

 

The OceanAire 2OACH is a portable air

-

cooled heat pump designed for permanent or 

temporary spot cooling or heating applications.    The entire unit has been built in a 

 

premium sheet metal cabinet, equipped with heavy

-

duty casters for mobility.  All 2OACH 

models come standard with a 10

-

foot power cord for electrical connection and added 

mobility in service.  These units direct heated/cooled air to specific areas or objects 

through a discharge grille located on the upper

-

front of the unit, while rejecting cooled/

heated air from the top of the unit.  The 2OACH models range in capacities from 12,000 

BTU/HR to 60,000 BTU/HR to satisfy most space cooling or heating requirements. 

 

 

The 2OACH is a self

-

contained unit with the entire system (evaporator and condenser 

blower assemblies,  electrical and refrigeration components), neatly arranged in a gray 

and blue polyester powder coated metal cabinet.  When connected to the proper source 

of electrical power, the 2OACH is controlled by a solid

-

state electronic controller, with 

numerous options of temperature and airflow controls that will provide the desired level 

of comfort when cooling or heating.

 

 

A wide variety of accessories and factory installed options are available for the 2OACH 

units allowing for improved performance and added versatility.  

 

WARRANTY CARD 

 

 

It is important that the warranty card be filled out completely and returned to the factory 

within fourteen (14) days of installation of the unit in order to receive the benefits of the 

warranty.

 

1

 

NOMENCLATURE

 

 

 

 

 

  

2O

  AC  H  60  1  2

 

DELUXE

 

PORTABLE

 

 

 

 

 VOLTAGE

 

 

AIR

-

COOLED

 

 

 

 

 PHASE (1 or 3)

 

 

HEAT PUMP

 

 

 

 

 NOMINAL 

 

 

 

 

 

                 CAPACITY 

 

 

CAPACITY RATING 

 

 

12..........12,000 BTU/HR

 

18..........18,000 BTU/HR

 

24..........24,000 BTU/HR

 

36..........36,000 BTU/HR

 

60……...60,000 

BTU/HR

 

NOT APPROVED FOR OUTDOOR USE

 

 

WARRANTY

 

ALL OCEANAIRE PRODUCTS ARE COVERED BY THE

 

OCEANAIRE LIMITED WARRANTY

 

1 YEAR ON THE FULL PRODUCT

 

PLUS, 4 ADDITIONAL YEARS FOR THE COMPRESSOR

 

(Restrictions Apply)

 

Summary of Contents for 2OACH1811

Page 1: ...ENGINEERING INSTALLATION AND SERVICE MANUAL 2OACH SERIES Portable Air Cooled Heat Pump Form EISM 2OACH 01012019...

Page 2: ...ontinuous improvement the items and procedures described in this manual are subject to change without notice Please note model and serial number of the 2OACH unit before contacting the factory TABLE O...

Page 3: ...and blue polyester powder coated metal cabinet When connected to the proper source of electrical power the 2OACH is controlled by a solid state electronic controller with numerous options of temperat...

Page 4: ...T WEIGHT lb 180 400 520 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 2OACHSPECS010119 115 1 1200 1950 208 230 1 60 100 53 500 36 050 32 500 3620 6000 10 0 10 0 3 5 5 Gallon Condensate Tank STANDARD...

Page 5: ...mode and the indoor blower will run continuously at one of six levels of fan speed CONDENSATE TANK PUMP 2OACH units come equipped with a means for handling the condensate generated during the cooling...

Page 6: ...exhaust duct directs the warm air away from the space allowing the evaporator air to cool the specific area ROOM AIR CONDITIONER When ducted properly the 2OACH can be used as a room air conditioner to...

Page 7: ...2OACH is a heat pump and the supply air will feel warm but not extremely hot to the touch Nozzle kits can be used for directional heating OUTDOOR FAN DISCHARGE COLD RETURN AIR GRILLE AND FILTER ELECTR...

Page 8: ...for plug and receptacle details for all 2OACH models A DAMAGED LCDI POWER SUPPLY CORD MUST BE REPLACED WITH A NEW POWER SUPPLY CORD AND NOT REPAIRED UNIT MODEL PLUG CONFIGURATION RECEPTACLE 115 VOLT...

Page 9: ...SION CORD CAN BE USED PROVIDED IT IS RATED AT LEAST 50 AMPS 250 VOLTS WITH GROUNDING TYPE ATTACHMENT PLUG AND GROUNDING TYPE CONNECTOR LOAD FITTING FOR MODELS 2OACH3632 AND 2OACH6032 AN EXTENSION CORD...

Page 10: ...l make the tank easier to remove MAXIMUM WATER LEVEL 4 FROM TOP OF TANK CAUTION UNPLUG UNIT BEFORE REMOVING TANK TO ADJUST THE SET SCREW CONDENSATE SUMP TOP OF TANK WHEN PLACED IN UNIT SUMP DRAIN HOLE...

Page 11: ...EPARATELY EVAPORATOR RETURN AIR PLENUM CONDENSER RETURN AIR PLENUM DISCHARGE DUCT ADAPTER CEILING PANEL KIT CK CEILING PANEL KIT CK PL NOTE IT IS IMPORTANT TO SPECIFY MODEL NUMBER AND SERIAL NUMBER WH...

Page 12: ...DDA 16 16 Inch Round 2OACH36 60 CONDENSATE PUMP KIT 2DPC 1 115V Models 2DPC 2 230V Models Not Required for 2OACH60 s CEILING PANEL KIT Includes Panel Duct Strap and Flange CK 12 2OACH12 18 24 CK 16 2O...

Page 13: ...vailable for 2OACH12 18 and 24 The ceiling panel kit consists of 8 feet of flexible duct a 2 X 2 lay in ceiling panel and a 12 inch duct flange that attaches to the condenser air discharge opening on...

Page 14: ...sed length of 20 inches The extended length is approximately 29 inches The nozzle kits come pre assembles with the nozzles secured to a mounting plate and with edge guards By removing the 2OACH discha...

Page 15: ...DENSER RETURN AIR PLENUM NOTE When installing the condenser return air plenum with a ceiling panel kit allow for a minimum separation distance of 2 feet between the unit discharge duct and the return...

Page 16: ...r rigid to the return air intake to reduce air noise and increase the number of options for solving difficult application problems The plenum attaches to the front of the unit replacing the return air...

Page 17: ...e to a 6 inch diameter round duct 2DDA 10 for models 2OACH18 and 2OACH24 converts the evaporator discharge to a 10 inch diameter round duct 2DDA 16 for models 2OACH36 AND 2OACH60 converts the evaporat...

Page 18: ...proper NEMA receptacles refer to Electrical service plug configuration When using extension cords use the proper gauge cord and check cord voltage to the unit TIME DELAY FUSES CIRCUIT BREAKERS ARE REC...

Page 19: ...is needed to change between cooling and heating modes COOL The system will operate in cooling mode only HEAT The system will operate in heating mode only MOISTURE CONTROL The system operates in the co...

Page 20: ...help to avoid freeze ups P4 Adjust the P4 setting to match the actual INSIDE room temperature if needed P10 Use this parameter to display temperatures in the desired units P13 To cycle the evaporator...

Page 21: ...hours 03 and 486 3486 hours 01 and 59 1059 hours TOTAL HOURS REPRESENTS COMPRESSOR RUN TIME MODEL CODE SETTINGS 2OACH12 P1 65 P2 45 2OACH18 P1 80 P2 50 2OACH24 P1 70 P2 50 2OACH36 P1 85 P2 40 2OACH60...

Page 22: ...wo nuts securing the display to the front panel Unplug the display cable and remove display Install new display and secure Plug in display cable C POWER MODULE To remove the power module remove the re...

Page 23: ...TOR FAN RUNS BUT COMPRESSOR AND CONDENSER FAN DO NOT START CAUSE SET POINT setting may be too high for cooling or too low for heating REMEDY Make sure set point is adjusted accordingly You should see...

Page 24: ...them in a solution of warm water and detergent for 10 minutes Then rinsing them clean with hot water and shaking excess moisture from filter CONDENSATE PUMP Condensate pumps come standard on all Size...

Page 25: ...INTERIOR VIEW Filter Drier Evaporator Blower Motor Condenser Blower Motor Condenser Coil Evaporator Coil Electronic Controller Thermostat Display Cable Condensate Tank Reversing Valve Control Box Hot...

Page 26: ...24 PIPING SCHEMATIC...

Page 27: ...25 WIRING SCHEMATIC FOR 2OACH12 18 and 24 DISCHARGE TEMP SENSOR...

Page 28: ...26 WIRING SCHEMATIC FOR 2OACH3612 DISCHARGE TEMP SENSOR...

Page 29: ...27 WIRING SCHEMATIC FOR 2OACH6012 DISCHARGE TEMP SENSOR...

Page 30: ...rt delay has timed out If the thermostat does not power up an electrical condition may need to be addressed Remove the control box cover and observe the LED on the phase monitor The LED signals the fo...

Page 31: ...29 WIRING SCHEMATIC FOR 2OACH3632 DISCHARGE TEMP SENSOR...

Page 32: ...30 WIRING SCHEMATIC FOR 2OACH3634 DISCHARGE TEMP SENSOR...

Page 33: ...31 WIRING SCHEMATIC FOR 2OACH6032 DISCHARGE TEMP SENSOR...

Page 34: ...32 WIRING SCHEMATIC FOR 2OACH6034 DISCHARGE TEMP SENSOR...

Page 35: ...ritten instructions or has been altered or modified in any way b Product that has been subjected to any abnormal power conditions such as loss of power power surges voltage irregularities such as brow...

Page 36: ...___________________________ Purchased from _______________________________ Date Installed _________________________________ For Technical Support or service parts contact our Keep Cool Team at 847 583...

Reviews: