Enertrax download direct from the AcquiLite

Obvius provides a free tool called Enertrax DL that can automate the process of downloading log data from the AcquiLite to 
your Windows PC hard drive.  Enertrax DL can merge new log data into existing log files on your computer as well as 
provide configuration information about the AcquiLite.  Enertrax DL can also be configured to make LAN or Dialup calls to 
one or more AcquiLite or AcquiSuite data acquisition servers.   Enertrax DL can be obtained from the obvius.com website in 
the Products section. 

HTTP/Post Upload To Building Manager Online

AcquiLite sends data to the BMO website 

The BMO Website stores the data in a SQL database. 

Quick reporting from our website 

Includes remote AcquiLite configuration service. 

Includes alarm notification by email. 

Data available for download in CSV/Tab delimited format upon your request. 

For pricing and to sign up for service, contact 

[email protected]

 or call +1-503-601-2099 

HTTP/Post Upload To Your Database Server

AcquiLite uploads data directly to your webserver or database server. 

You must supply a script to process the incoming data. Sample script for ASP and PHP are available upon request. 

Requires Webserver, CGI scripting and database (SQL) knowledge 

Alarm processing available by processing data on your server when data is uploaded 

Designed for integration with existing energy reporting systems. 

Contact Obvius technical support for further details and sample scripts.

Removing Data From the AcquiLite

When using an HTTP/Post method to allow the AcquiLite to push data to a database server, the AcquiLite will automatically 
remove log files from its flash memory once the AcquiLite has confirmed that the file was received by the database server.

If you are using the AcquiLite with a standalone mode, you can use FTP  or Enertrax DL to delete log files from the flash 
memory. 

With EnertraxDL, simply check the setup checkbox to delete log data after download.  

For FTP,  the process  is essentially the same process as  the manual FTP data download. For more information on FTP 
access to the AcquiLite, please view the FAQ and Technotes section of the Obvius.com website. 

Steps for Microsoft Windows command prompt ftp.

Use the following  commands.

ftp 192.168.40.50      

Use the IP address of your AcquiLite

username: root

password: admin        

The same as the admin password

cd /var/log/modbus

dir                    

view a list of log files.

mdel *.gz              

remove the log file to free up flash space

bye

The mdel command will tell the FTP software to delete all files ending in .gz in the current directory.  Some FTP clients will 
allow you to specify a command “prompt” prior to using mdel that will prevent the FTP client software from asking if you 
are sure you wish to delete each file. 

Page 27

A7810 AcquiLite – Data Acquisition Server

www.calcert.com

[email protected]

1.800.544.2843

0

5

10

15

20

25

30

Summary of Contents for AcquiLite EMB

Page 1: ...Data Acquisition Server Obvius LLC Installation and Operation Manual Model A7810 Date Aug 10 2011 Page 1 A7810 AcquiLite Data Acquisition Server www calcert com sales calcert com 1 800 544 2843 0 5 1...

Page 2: ...utside of Obvius s authorized facilities 4 has not been sold subject to other warranty terms specified at the time of sale and 5 is still owned by the original purchaser This warranty provides specifi...

Page 3: ...oting Ethernet Problems 18 System Options 18 Status 18 Processes 18 Date and Time 18 Universal Time Is Your Friend 19 System logs 19 Firmware Update 20 Diagnostics 20 Host Lookup 20 Connection Test 20...

Page 4: ...it connection point hub or switch IP address and Netmask check with system administrator Gateway address check with system administrator DNS server address check with system administrator HTTP Proxy a...

Page 5: ...ms Pulse rate option 100hz minimum pulse width 5ms Contact closure threshold 100 to 2 5k user selectable Pulse count values are stored in non volatile memory Isolation2 The RJ45 Ethernet is isolated t...

Page 6: ...erous if wire scraps come into contact with high voltage wires Step 4 Power up and diagnostics A power supply is not provided with the AcquiLite EMB therefore it is up to the installer to provide the...

Page 7: ...e AcquiLite or Dynamic Host Configuration Protocol DHCP address this process assigns an IP address dynamically to the AcquiLite when it is connected to the network from a host DHCP server or Direct co...

Page 8: ...ained automatically Simply select the Enable DHCP from the first TCP IP configuration menu Step 4 After the address information has been set you must reboot the AcquiLite Select the Previous Menu opti...

Page 9: ...d the scope of this document however A From the Windows start menu select the Settings Network Connections option Double click the Local Area network connection icon in the network folder then click t...

Page 10: ...steps for each Modbus device Step 7 Select the Modbus Setup menu option Specify the Modbus Loop Name This will become the name of the AcquiLite This is the name that will appear on the BMO website se...

Page 11: ...ord for read only access Log information is stored in var log modbus For read write delete access use the login name root and the admin password The three usernames specified are not able to be change...

Page 12: ...used to configure a Modbus device that is not presently connected to the system add a framework configured device or add a Modbus TCP connected device See the section on manually adding a device below...

Page 13: ...the page several buttons are present Done returns you to the device list page Log File This icon will display a table view of the most recent data in the current log file Use the log file export page...

Page 14: ...ta points are rotated about every 10 seconds The values on the LCD console are updated when the next log interval occurs Point Config Some devices have configurable point features Most data points are...

Page 15: ...dress already listed in the device list page Modbus TCP Gateway IP This option allows the AcquiLite to log data from a remote Modbus device that is attached to the LAN via a Modbus TCP gateway device...

Page 16: ...control based on the IP address of the system making the request The Modbus TCP protocol does not have provisions for any authentication password or other methods of security By default the gateway fe...

Page 17: ...the wireless diagnostics options will be present in the AcquiLite Please refer to the AcquiSuite A8812 or A8810 user manuals for further details on the wireless diagnostic features Networking Network...

Page 18: ...mmon mistake is configuring the Laptop IP to the same address as the IP address of the AcquiLite In order for the laptop and AcquiLite to communicate the IP addresses should not be identical see the b...

Page 19: ...data in the database in UTC format and then convert the information when generating a report for the user For example if you wish to draw a graph of KW over Time prompt the user for a date range say J...

Page 20: ...es will be displayed If any firmware updates are available a button to the right will be shown labeled Download The firmware files are asarm cramfs The main AcquiLite firmware file including the modbu...

Page 21: ...failure is due to the password not being correct LCD Console The AcquiLite has an LCD console and two push buttons labeled Menu and Select These can be used to configure some of the basic features of...

Page 22: ...ng requests This test does not verify if the DNS servers can actually resolve DNS names to IP addresses For a more complete test use the Connection Test web page in the AcquiLite diagnostics menu Modb...

Page 23: ...ame starts with mb xxx where xxx is the Modbus device address number One file with the log extension is the file where the most recent data is being stored Other log files have a gz extension These ar...

Page 24: ...No space left on device 32 Broken pipe 52 Invalid Exchange 101 Network is unreachable 110 Connection timed out 111 Connection refused 113 No route to host 129 Illegal Function function was not allowe...

Page 25: ...log files to your server you must manually delete them To delete log files refer to the FTP method of downloading log files One step detailed in the FTP section is how to delete a log file from the Ac...

Page 26: ...nformation about the transfer process use the Connection Test page in the Testing Diags menu on the AcquiLite for a full report of the data upload progress Retrieving Data From the AcquiLite Overview...

Page 27: ...s uploaded Designed for integration with existing energy reporting systems Contact Obvius technical support for further details and sample scripts Removing Data From the AcquiLite When using an HTTP P...

Page 28: ...be shown on that dialog Simply copy paste this URK into your link The AcquiLite can provide Modbus device data in XML format This feature coupled with browser based AJAX Javascript can provide a very...

Page 29: ...roximately 4 x 4 25 x 2 deep The AcquiLite has 4 mounting holes for use with a 6 screw The drawing above shows the relative position of the mounting holes Page 29 A7810 AcquiLite Data Acquisition Serv...

Reviews: