12. Configuration-Reset (Factory setting)
With the help of the jumper B2 it is possible to set the reader back to the factory settings.
1. Disassembly the upper part of the reader housing, see chapter: 9. Installation)
2. Put a 2 mm jumper to connector B2 and power on the reader again. For this connect the reader
again with the adapter board.
3. An alternating beep signal indicates a successful configuration reset.
4. Now the jumper must be removed
Note:
after this configuration reset also the TCP/IP settings and the crypto settings for the TCP/IP
encryption are set back to the factory settings.