How to change filter
When the indicator lamp/lamps for changing of filter “FILTER RESET - HEPA/
ODOR” flashes/flash, the filter/filters should be changed immediately as
follows:
1.
Unplug from the wall outlet.
2.
Open the front of the appliance by pulling the upper part outwards (see fig.)
Remove the filter to be changed (coal filter (black filter) every 6 months,
the HEPA filter once a year) and replace it/them by a new filter/filters
(available in our shops) Put the filter/filters back in in the correct order, the
HEPA filter at the innermost position with the Velcro flaps facing outwards.
Secure the charcoal filter (black) under the plastic hooks on the back of
the coarse filter (mounted in a plastic frame). Position the coarse filter with
the charcoal filter facing the Velcro flaps of the HEPA filter and click it into
place. Check that the text ”FRONT” on the plastic rim of the coarse filter is
facing outwards to show that the filter has been correctly mounted. Next,
fasten the front of the appliance again by inserting the plastic spikes at the
bottom of the front in the corresponding grooves of the appliance. Close the
front and press until it is correctly positioned.
3.
Next, press the reset button ”FILTER RESET” on the control panel for 2
seconds till it goes out. Please note that the AIR QUALITY indicator is not
on, if the HEPA and/or ODOR indicators have been activated.
4. Clean the coarse filter in accordance with the instructions given in ”Cleaning
and maintenance”.
The lifetime of the filter is based on 8 hours’ use a day at maximum speed. The
recommended replacement intervals may vary depending on where and how
the appliance is used.
If any of the filters need to be replaced before the indicator lamp for changing
of filter goes on, you can manually reset the calculation of cycle of the
appliance by pressing the reset button (FILTER RESET) for 2 seconds. Now
press the reset button again to choose the filter (HEPA or ODOR). Press and
keep pressed the reset button again for 2 seconds and the time reminder is
deleted. Note that you should repeat this procedure within 10 seconds after
the activation of the reset button.
Cleaning and maintenance
•
Always unplug before cleaning and maintenance.
•
Never immerse the appliance or the cord in water or any other liquids.
•
Do not use scouring or etching detergents for cleaning.
• The air quality sensor should be cleaned every two months (in case of
regular use) by opening the small hatch at the right hand side of the
appliance. Wipe the room with a damp cloth and wipe dry with a dry cloth
and close the hatch. The air inlet and the air outlet positioned above or
underneath the hatch, respectively, should be cleaned with a soft brush or
with a vacuum cleaner.