Figure 5 – Snap the Firestop Grommet around the Data Cable and pull through the Conduit Connector as shown.

 

 

Figure 4 

 

 

Step 5 

– Run the data and power cable (if required) through the 

conduit  connectors  which  have  been  installed  in  sides  of  the 

access  point  enclosure

.    In  order  to  maintain  a  separation  of 

signal  and  power,  install  the  data  and  power  cables  through 
opposite  sides  of  the  enclosure.  Snap  the  fire  stop  grommet 
around the cable and insert it into the conduit connector and pull 
the  data  cable  through  far  enough  to  allow  attachment  to  the 
access  point  (8"  -  10").  Attach  any  additional  data  cables  as 
necessary and power up the networked devices. 
 

Step  6 

 

(For  Wall  Installation  Only)

  Mo

del  1028-08-ANT5-B 

requires at least 8” of free space above the ceiling or behind the 
wall  to  allow  for  clearance.  The  Anchoring  points  on  the  flange 
are  16"  apart.  For  wall  installation,  cut  a  14”  X  18”  hole. 
Additional  clearance  and  bracing  may  be  necessary.  Use 
appropriate  hardware  to  secure  the  enclosure.  Drywall  anchors 
and cinderblock anchors may be used. 
 

Step  7 

–  If  stud  spacing  permits,  position  the  enclosure  so  that 

the mounting holes are centrally located with the studs. For metal 
studs, use #10 sheet metal screws (or, for wood studs, use #10 
wood screws). The screws should be a minimum of 2" in length. 
Make  sure  that  the  screw  is  inserted  directly  into  the  stud. 
Securely  tighten  the  screws  after  inserting  them  through  the 
screw  snap  cap  washer,  and  be  sure  that  the  screw  is  inserted 
directly  into  the  joist.  Press  the  provided  screw  snap  caps  onto 
the  screw  head.  Alternatively,  if  no  studs  are  available  for 
mounting, drywall anchors or cinderblock anchors may be used. 
Be  sure  to  use  appropriate  hardware  for  the  wall  construction 
type. (Reference Figure 4) 

**  IMPORTANT**

  - 

This  is  an  important  safety 

feature that could prevent human injury or damage to 
the equipment should the unit become dislodged from 
the ceiling

.

 

 

Step 8

 –

 (For Ceiling Installation Only) 

Use hanger wires (included) to support the 

enclosure

. Attach one end of the wire to the mounting 

brackets located along the edge of the back box and the other end to a permanent structural component of the building such as a joist. Two 
supporting 

grid 

wires 

should 

be 

attached 

to 

each 

corner. 

Reference 

Oberon’s 

OPA 

1638 

drawing 

(at 

http://oberonwireless.com/WebDocs/OPA-1638-10.pdf

). For ceiling installation, cut a 18” tall X 14” wide rectangular hole. If space permits, 

position the enclosure so that the mounting holes are centrally located with the joists. For metal joists, use #10 sheet metal screws (or, for 
wood  joists,  use  #10  wood  screws).  The  screws  should  be  a  minimum  of  2"  in  length.  Securely  tighten  the  screws  after  inserting  them 
through the screw snap cap washer, and be sure that the screw is inserted directly into the joist. Press the provided screw snap caps onto 
the screw heads. 
 

Step 9

 – Close and lock the access door. Extra force may be necessary to compress the gasket. The installation is now completed. 

NOTE:

 Additional sealing precautions around edges of the enclosure may be necessary. 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 

 
 

Page 4 

 

MODEL 1028-08-ANT5-B 

Installation Instructions 

 

**** WARNING **** 

 

Please thoroughly read the product warning below before 

installation to provide for a safe work environment. 

 

1.  Ceiling mounted products should be installed in accordance with National Electric Code paragraphs 300.10 (Electrical 

Continuity of Metal Raceways and Enclosures) and 300.11 (Securing and Supporting). Independent support wires or 
other  means  must  be  used  for  the  installation  of  this  product  in  the  ceiling.  Acoustical,  suspended,  false,  drop  and 
concealed  spline  ceiling  grid  work  is  not  designed  to  support  the  weight  of  this  product.  Oberon’s  ceiling  mounted 
products  have  four  support  wire  tabs  on  the  back  box.  These  tabs  shall  be  used  for  supporting  the  product  with 
independent  support  wires,  wire  rope,  threaded  rod,  or  other  secure  support  means  of  adequate  gauge  and  fire 
resistance. 

 

2.  When closing the enclosure access door, be sure that the cam lock is completely engaged to prevent the access door 

from accidentally swinging open. 

 

3.  When opening the enclosure door, be sure to support the door to prevent the door from accidentally falling open. 
 
4.  This  enclosure  has  a  maximum  operating  ambient  of  55º  C  (131º  F),  the  temperature  within  the  enclosure  may  not 

exceed this temperature, depending on power dissipation within enclosure. 

 
5.  A  minimum  air  clearance  of  1“  between  the  housing  of  the  access  point  and  the  enclosure  side  walls  must  be 

maintained for the safe operation of the equipment. 

 
6.  This product is intended to be installed by trained personnel. 
 
7.  Only Listed ITE products and Listed AC Receptacles shall be installed within the enclosure. 
 
8.  This product is to be repaired by personnel trained by the manufacturer or returned to the manufacturer for repair or 

replacement. 

 
9.  Maximum weight to be installed in the unit is 44 lbs. 
 
10.  All  knockouts,  openings,  and  holes  shall  be  sealed  with  a  plug  constructed  of  metal,  or  a  non-metal  material  that 

complies with UL 2043 or UL 1479. 

 
11.  All unused mounting holes should be sealed with tape or other material that complies with UL 1479. 
 
12.  If  AC  power  is  used  inside  the  enclosure,  connect  the  ground  wire  to  the  green  ground  screw  located  near  the 

knockout in the backbox. 

 

 
 
 