To attach the assembled mount on the wall, align the keyhole slots on the
back of the Model 1012
-
00 with the screws in the wall and slide the
mount down so that the screws are at the top of the slot. Tighten the
screws to secure the mount to the wall, and attach any necessary cables.
Para colocar el soporte ensamblado en la pared, alinee las ranuras de la
cerradura en la parte posterior del modelo 1012
-
00 con los tornillos en la
pared y deslice el soporte hacia abajo de modo que los tornillos queden
en la parte superior de la ranura. Apriete los tornillos para fijar el soporte
a la pared y conecte los cables necesarios.
2
Attach the data and power cables to the access point prior to securing
the AP to the Receiver Plate. Slide the mounting feet of the Cisco AP into
the Receiver Plate’s four (4) keyhole slots marked with the letter “D”.
To secure the Cisco AP to the receiver plate, use one of the included #6
-
32 x 1/4” pan head screws as a set screw in either the hole marked with
the letters “F/G/H” or “F/H”.
NOTE:
If installing a Cisco 2700 or 3700
series AP,
the hole marked with the letters “F/G/H” must always be used.
(Reference the AP mounting legend on page 1, if necessary).
Attach the data and power cables to the access point prior to securing the
AP to the Receiver Plate.
(For Aruba 3XX Series APs Only)
Align the mounting feet of the Aruba AP
with the stepped openings (marked with the letter “A”) in the middle of the
receiver plate and slide the AP into position. Insert one (1) of the included
#6
-
32 x 1/4” pan head screws in the hole marked with the letter “I” to secure
the AP. (Reference the AP mounting legend on page 1, if necessary).
(For Aruba 5XX Series APs Only)
Align the two (2) threaded holes and (2)
“D” shaped bosses of the Aruba AP with the four (4) corresponding holes on
the receiver plate. (See AP mounting legend on page 1). The AP should be
aligned so that its data port is facing towards the wall. Use the two (2) in-
cluded M4 x 8 mm flat head screws to secure the AP to the receiver plate.
Conecte los cables de datos y de alimentación al punto de acceso antes de
asegurar el AP a la placa receptora.
(Solo para AP de la serie Aruba 3XX)
Alinee las patas de montaje del AP
Aruba con las aberturas escalonadas (marcadas con la letra “A”) en el me-
dio de la placa del receptor y deslice el AP a su posición. Inserte uno (1) de
los tornillos de cabeza plana #6
-
32 x 1/4” incluidos en el orificio marcado
con la letra “I” para asegurar el AP. (Consulte la leyenda de montaje del AP
en la página 1, si es necesario).
(Solo para AP de la serie Aruba 5XX)
Alinee los dos (2) orificios roscados
y los (2) salientes en forma de “D” del AP Aruba con los cuatro (4) orificios
correspondientes en la placa del receptor. (Consulte la leyenda de montaje
del AP en la página 1). El AP debe estar alineado de modo que su puerto
de datos mire hacia la pared. Utilice los dos (2) tornillos de cabeza plana
M4 x 8 mm incluidos para asegurar el AP a la placa del receptor.
***It is important that the mount is securely fastened to pre-
vent human injury or damage to the access point.
***Es importante que el montaje esté fijado de manera segu-
ra para evitar lesiones en personas o dañar el punto de ac-
ceso.
Mark the screw hole locations on the wall using the Model 1012 Hole Pat-
tern Template or the Model 1012
-
00 itself. The mount can be conveniently
installed directly over a telecommunications outlet. It is recommended that
the mount be fastened to a stud if possible. Use a minimum of two (2) #10 x
2” or larger screws (not included) to secure the mount to a stud. If there is
no stud at the mounting location, use four (4) wall anchors suitable for the
wall construction, such as threaded drywall anchors, threaded drywall tog-
gles, sleeve type hollow wall anchors (a.k.a. Molly Bolts) or toggle bolts.
There should be enough clearance between the bottom of the screw head
and the wall for the enclosure’s keyhole slots to engage the screws. Due to
the weight of the AP and mount, plastic wall anchors are not recommended
for fastening mount to the wall.
NOTE:
See Step “1b” for further information regarding the Model 1012 Hole
Pattern Template.
Marque las ubicaciones de los orificios de los tornillos en la pared utilizando
la plantilla de patrón de orificios modelo 1012 o el modelo 1012
-
00 en sí. El
soporte se puede instalar cómodamente directamente sobre una toma de
telecomunicaciones. Se recomienda que el soporte se sujete a un montante
si es posible. Use un mínimo de dos (2) tornillos #10 x 2” o más grandes (no
incluidos) para asegurar el soporte a un montante. Si no hay montantes en
la ubicación de montaje, use cuatro (4) anclajes de pared adecuados para
la construcción de la pared, como anclajes roscados para paneles de yeso,
pernos roscados para paneles de yeso, anclajes de pared huecos tipo
manguito (también conocidos como pernos Molly) o pernos articulados.
Debe haber suficiente espacio libre entre la parte inferior de la cabeza del
tornillo y la pared para que las ranuras de la cerradura encajen con los
tornillos. Debido al peso del AP y del soporte, no se recomiendan los ancla-
jes de pared de plástico para sujetar el soporte a la pared.
NOTA:
Consulte el paso “1b” para obtener más información sobre la plantil-
la de patrón de orificios modelo 1012.
The Model 1012 Hole Pattern Template can be found on the third page of
the
1012
-
00 Customer Print
. If the use of this template is desired, print
the page on a standard “A” size sheet of paper (8.5” x 11”). After printing
the hole pattern template, measure the vertical and horizontal center
mark distance and compare each measurement to the respective dimen-
sion on the template. If either of the measurements do not match the
corresponding dimension on the template, the page was not printed to
scale. An example of the template is shown above.
La plantilla de patrón de orificios modelo 1012 se puede encontrar en la
tercera página de la
impresión del cliente 1012
-
00
. Si desea utilizar esta
plantilla, imprima la página en una hoja de papel de tamaño estándar
"A" (8.5 "x 11"). Después de imprimir la plantilla del patrón de agujeros,
mida la distancia de la marca central vertical y horizontal y compare cada
medida con la dimensión respectiva en la plantilla. Si alguna de las me-
didas no coincide con la dimensión correspondiente en la plantilla, la
página no se imprimió a escala. Arriba se muestra un ejemplo de la plan-
tilla.
1b
Cisco
Aruba
Conecte los cables de datos y de alimentación al punto de acceso antes de
asegurar el AP a la placa receptora. Deslice las patas de montaje del Cisco
AP en las cuatro (4) ranuras de ojo de cerradura de la placa receptora mar-
cadas con la letra "D".
Para asegurar el Cisco AP a la placa del receptor, use uno de los tornillos
de cabeza plana #6
-
32 x 1/4” incluidos como tornillo de fijación en el orificio
marcado con las letras “F/G/H” o “F/H”.
NOTA: Si instala un AP Cisco de
la serie 2700 o 3700,
siempre debe usarse el orificio marcado con las let-
ras "F/G/H".
(Consulte la leyenda de montaje del AP en la página 1, si es necesario).
3a Cont.