1. 

IMPORTANT WARNINGS & SAFETY INSTRUCTIONS 

IMPORTANT WARNINGS 

This manual contains important information about the installation, operation and safe use of this 
product. This information should be given to the owner and/or operator of this equipment. When 
installing and using this equipment, basic safety precautions should always be followed. Failure 
to  follow  safety  warnings  and  instructions  in  this  manual  can  result  in  serious  injury  and/or 
damage  to  your  equipment.  Read  and  follow  all  warning  notices  and  instructions  which  are 
included in this manual. 

Pool  and  Spa  water  circulation  systems  operate  under  hazardous  pressure  during  start  up,  normal 
operation, and after pump shut off. Stand clear of circulation system equipment during pump start-up.  

Failure to follow safety and operation instructions could result in violent separation of the pump housing 
and cover, and/or filter housing and clamp due to pressure in the system, which could cause property 
damage, severe personal injury, or death.  

Before servicing pool and spa water circulation systems, all system and pump controls must be in the 
off  position  and  filter manual  relief  valve must  be  in  open  position.  Before  starting  system  pump,  all 
system valves must be set in a position that allows system water to return back to the pool.  

DO NOT CHANGE FILTER CONTROL VALVE POSITION WHILST SYSTEM PUMP IS OPERATING. 

Before starting system pump, fully open filter manual air relief valve.  

Do not close filter manual air relief valve until a steady stream of water (not air) is discharged. 

Cleaning the media filter by BACKWASHING and RINSING is essential to providing clean, safe and 
healthy swimming water.  

To reduce the risk of injury, 

DO NOT 

 permit young children to use this product unless they have 

been trained by the person responsible for their safety and they acknowledge their ability to use 
such equipment. To reduce the risk of accidents or incidents, service on the unit should only be 
performed by your local pool Professional. 

FAILURE TO FOLLOW INSTRUCTIONS CAN CAUSE SEVERE INJURY AND / OR DEATH. 

CAREFUL REMINDERS 

• 

It  is  recommended  that  installation  of  all  equipment  is  complete  by  a  suitably  qualified  pool 
professional who will ensure your products are installed to your local standards / codes to ensure 
optimum safety and performance. 

• 

All components of the filtration system including Pumps, Filters, Heaters must be positioned so 
to prevent being used as means of access to the pool by young children. To reduce risk of injury, 
do not permit children to use or climb on this product. Closely supervise children at all times. 

• 

Make sure all wiring connections are clean and that all wiring and electrical equipment is in good 
condition.  Damaged  wiring  must  be  repaired  or  replaced  by  a  qualified  electrician  as  soon  as 
damage is discovered 

• 

Do  not  add  chemicals  directly  to  the  pool  skimmer.  Adding  undiluted  chemicals  may  damage 
pump, heater, etc and void warranty 

• 

Pump suction is hazardous and can cause entrapment, drowning or disembowel bathers 

• 

Do not block or cover any pool/spa suction 

• 

Do not use or operate swimming pools, spas or spa baths if a suction cover is broken, missing or 
loose 

• 

Suction covers and inlets must be installed as per Australian Standards guideline and provided 
for every pump to avoid suction entrapment 

Summary of Contents for SFG Series

Page 1: ......

Page 2: ...rchase Date Installer Warranty Registered Online Yes No See page 19 for details PRESSURE GAUGE READING RECORD Initial Reading Date PSI kPa Date PSI kPa Date PSI kPa Date PSI kPa Date PSI kPa Date PSI...

Page 3: ...ORKS 5 4 INSTALLATION 6 Start Up Procedure 8 5 MULTIPORT CONTROL VALVE FUNCTIONS 9 6 BACKWASHING 10 7 WINTERISING 11 8 SYSTEM TROUBLESHOOTING 11 9 POOL CHEMISTRY GUIDELINES 13 10 PRO ACTIVE MAINTENANC...

Page 4: ...y stream of water not air is discharged Cleaning the media filter by BACKWASHING and RINSING is essential to providing clean safe and healthy swimming water To reduce the risk of injury DO NOT permit...

Page 5: ...o operate the major features of the unit The importance of maintenance If you have a problem what to trouble shoot before you contact your pool service professional Finally your entitlements under you...

Page 6: ...pool through your piping system The entire process is continuous and automatic It is this process that provides the filtration and removal of organic material such as dust dirt and fine particles in...

Page 7: ...er 4 Position a corner of the filter media bag over the tank and carefully pour in correct amount and grade of filter media Work slowly and carefully to prevent any media from spilling Repeat until yo...

Page 8: ...PVC Pipe with the SFG25 40 Filter and minimum 50mm 2 0 PVC Pipe with all other SFG Filters To reduce any pressure and to provide the best clean possible reduce the distance and amount of bends used f...

Page 9: ...ilter mode filtering dirt particles from the pool water 5 Adjust pool suction and return valves to achieve desired flow Check system and filter for water leaks and tighten connections bolts nuts as re...

Page 10: ...E By passes filter used for vacuuming to waste or lowering water level The waste position allows you to pump excess water from the pool directly down the waste pipe This position is useful after heavy...

Page 11: ...edia bed and then out through the waste line This will settle the media bed back for normal operation 8 Check sight glass Continue until water is running clear 9 Turn off filter pump 10 Change the pos...

Page 12: ...at may be required during the off season Most pool professionals will recommend want is needed before the next pool season 8 SYSTEM TROUBLESHOOTING If you suspect for any reason your Oasis Aquatics SF...

Page 13: ...er Leak inside multiport control valve Leak from pool or PVC piping High Pressure Filter Filter requires backwashing Calcified media bed due to poor water chemistry Return lines too small for flow rat...

Page 14: ...at you employ the services of your local pool professional to get your pool set up to exactly what is required The below chart gives some guidelines to the major water chemistry areas to provide the b...

Page 15: ...structions Quarterly Check around the unit for leaves debris or signs of flooding Remove any debris that is restricting air circulation around the filter If in a flood prone location rectify Check for...

Page 16: ...Area Design Flow Height Diameter Media Glass Fine Glass Course mm m2 m3 h A B Kgs kgs kgs SFG25 40 40 0 32 15 60 950 635 145 45 60 SFG25 50 50 0 32 16 32 980 635 145 45 60 SFG28 50 50 0 41 20 16 1092...

Page 17: ...mm 1 REPLACEMENT PARTS OF MULTIPORT VALVE Item Part No Description Qty 1 01013003 Handle Big 1 2 03018008 Pin for Handle 1 3 01181001 Washer for Handle 1 4 89280107 M6 x 30 Screw with Nut for Standard...

Page 18: ...185mm 4 15 89012516 MFV27 MFV31 MFV35 Laterals bracket 4 16 01172007 Laterals 115mm 4 REPLACEMENT PARTS OF MULTIPORT VALVE Item Part No Description Qty 1 01013003 Handle Big 1 2 03018008 Pin for Hand...

Page 19: ...10107 Water Drain Set 1 11 1111062 21 28inch Filter Base For SFG28 50 1 11 1112038 32 40inch Filter Base For SFG32 50 SFG36 50 1 REPLACEMENT PARTS OF MULTIPORT VALVE Item Part No Description Qty 1 101...

Page 20: ...le for damage caused by but not limited to corrosion scaling or stress This warranty does not apply if failure is due to any abuse misuse improper installation or accident or to any of the following T...

Page 21: ...ional for comprehensive advice This guide includes subject s that should only be performed by or under the direction and advice of your local Professional and under no circumstances should the guide b...

Page 22: ...SFG SERIES TOP MOUNT FIBREGLASS MEDIA FILTER INSTALLATION AND OPERATION MANUAL Page 21 of 23 16 NOTES...

Page 23: ...SFG SERIES TOP MOUNT FIBREGLASS MEDIA FILTER INSTALLATION AND OPERATION MANUAL Page 22 of 23...

Page 24: ...3 A part of the Victoria 6 8 Austral Place Hallam VIC 3803 Australia T 03 9887 2131 New South Wales Unit 2 10 Boden Road Seven Hills NSW 2147 Australia T 02 9838 0000 Queensland 11 Andys Court Upper C...

Reviews: