A: Drilling hole in the top for water line connection.
1.
Disconnect power by UNPLUGGING unit. It might be necessary to
remove the front panel to get access to the power.
2.
Turn OFF water supply to the unit. It might be necessary to remove the
front panel to access the water stop valve.
3.
Place hole template onto cooler top so it is aligned with the left side of
unit and wall. SEE NEXT PAGE FOR TEMPLATE
4.
Mark hole location
5.
Remove top from unit.
Template
Mark hole location.
Drill
Install bushing
Remove top from cooler by
removing six #15 torx head screws
on sides of top.
Section 3: Installation
Note: Proceed to Sect 3B Step 5 if the cooler is
purchased “VersaFiller ready”.
6.
Using a step drill bit or 7/8” punch die, make a 7/8” hole through top. You
may want to drill a pilot hole to get these started.
7.
Install snap bushing into hole to protect tubing from being cut.