1.
With the cooler top removed, find the tube going from the cooling
tank outlet to the valve. The TEE fitting (supplied) will need to
connect between the cooling tank and valve.
Outlet Tube (insulated plastic)
Valve
P8AC family
Outlet Tube (insulated copper)
Valve
P8AM family
If the cooling tank is non-pressurized, then go to the “Pressurizing the
cooling tank” addendum section. Otherwise, proceed to step 1 below.
Non-pressurized units are single units made since December of 2009.
Refer to the schematic below to identify the system that you have.
PRESSURIZED
COOLING
TANK
C
o
o
lin
g
ta
n
k
Water
valve/
regulator
Supply
Water
NON-
PRESSURIZED
COOLING TANK
C
o
o
lin
g
ta
n
k
Water
valve/
regulator
Supply
Water
To retrofit the Versafiller to an existing unit, follow the
instructions below:
9