4
IMPORTANT REQUIREMENTS
QUASAR UV-C LED OPERATION
CAUTION:
Ensure bottle filler is properly grounded. It is required to attach the
long green ground wire to the frame assembly junction box in order for the unit
to function properly. Refer to the steps described in Step 4 on Page 12.
CAUTION:
Do not activate bottle filler electric eye sensor without running
water through the UV-C module. Operating the UV-C module dry may
damage the UV-C LED’s.
A.
B.
C.
D.
E.
QUASAR is a form of dispense point water treatment that utilizes UV-C LED’s to inactivate
pathogens.
Operation:
The QUASAR activation is automatic. The UV-C LED’s turn ON when water is dispensed
and OFF when the dispense stops.
During non-use periods the QUASAR automatically cycles ON for ten seconds every ten
minutes. This keeps the dispense point more sanitary between use.
When the QUASAR is ON, the LED light on the front of the alcove near the top will turn
ON. The LED will be BLUE when the QUASAR is working properly.
If QUASAR is not working properly, then the LED light on the front of the alcove near the
top will be RED or YELLOW. The light will remain ON and the system will not allow water
to be dispensed until the problem is resolved.
IMPORTANT:
Never operate the QUASAR without water connected to the system. Lack
of water can cause the QUASAR to overheat. If it is necessary to activate QUASAR to
purge the system of air, then the QUASAR will automatically shut off if it overheats. But
the module will resume operation once water begins to flow through it.