background image

2 of 6

1. INSPECTION

Inspect the cartons and various components for evidence of rough handling and concealed damage.  Damage 

claims should be filed with the carrier.

2. INSTALLATION, PLUMBING & ELECTRICAL CONNECTIONS

a) Note:  

The following states require a licensed plumber to install cooler; AR, GA, MA, MI, OK, RI, SC, SD, TX, 

VT and WI. CA, KS, MN, NM and OR allow for a state-registered installer or contractor as well.  State and 

local plumbing codes may prohibit the use of saddle tapping valves for water line connection in some 

applications.  All connections must conform to applicable plumbing codes.

b) Plumbing rough-in and wall opening should be prepared as shown on Roughing-in drawing.  This drinking 

water cooler is designed to be operated at a water supply line pressure of up to 100 psi (690 kPa). A pressure 

regulator must be installed in front of the unit’s water inlet if the water pressure (including any possible 

pressure spikes) could exceed 100 psi (690 kPa).

c) Insert frame assembly into wall opening and secure to studs.  NOTE:  FRONT FLANGE OF FRAME MUST BE 

FLUSH WITH THE FINISHED WALL SURFACE.

d) It is recommended that flexible conduit be used to supply power when applicable to electronic bottle filler 

electrical box in frame.  Check electric current available.  Type and voltage must be the same as listed on unit 

data plate.  This drinking water cooler is intended to be connected to a 20A minimum ground fault circuit 

interrupting (GFCI) device to meet UL requirements.

e) Install provided waste tee to bottle filler tailpiece. 

f) Install the fountain mounting plate to the frame assembly using provided screws.

g) Prior installing upper panel assembly with hands free bottle filler: 

1) To ease access to the remote toggle button for programming once the panel assembly and fountain 

is installed, feed the remote toggle button through the fountain mounting plate noted in step f.  

After unit is completely assembled, refer to the “Set-Up Guide for Oasis® Hands-Free Bottle Filler 

Electronics” to change program settings.

2) Attach the long green ground wire to the electrical box and plug in cord for sensor operation.

i) Place panel in place on frame top angle and fasten with 2 flat head screws, provided, at the bottom.

j) Remove bottom plate from fountain arm.  Save the screws.

k) Snap reveal gasket over back end(s) of fountain arm.

l) Add compression connector, furnished by others, to fountain waste tube and slide back approximately 3" 

out of way.  Use a 3/8 compression fitting for water line connections, provided by others.  An internal 

strainer is provided for water line connection.  For dielectric isolation of fountain(s) a non-metallic water line 

connection can be used.

m) Hang fountain on mounting plate studs.  

NOTE:  AS THE FOUNTAIN IS HUNG, FEED THE WASTE TUBE INTO 

THE WASTE STUB ON THE WALL SIDE. 

n) Tighten fountain to mounting plate with the 5/16-18 nuts and washers and the 1/4-20 bolts and washers 

provided.

o) Complete plumbing to fountain and bottle filler.  Tighten waste connection and then connect water supply 

line with the 3/8 compression fitting. 

p) Slide reveal gasket back into notch between panel and arm.  The gasket serves as an appearance item only 

(to close up any opening around panel and mounting plate).

q) Check plumbing connection for leaks.  On new plumbing installations, run water through the bubbler until 

water taste is satisfactory.  Adjust regulator to achieve desired stream height.  Reinstall bottom plate back to 

fountain arm 

OASIS

®

AQUA POINTE

®

DRINKING FOUTAIN WITH BOTTLE FILLER

INSTRUCTIONS

Reviews: